Profil

Kerckhofs Greet

See author's contact details
Main Referenced Co-authors
Schrooten, Jan (67)
Wevers, Martine (60)
Van Bael, Simon (23)
Geris, Liesbet  (21)
Moesen, Maarten (19)
Main Referenced Keywords
Animals (5); Humans (5); Mice (4); Porosity (3); Tissue Engineering/methods (3);
Main Referenced Unit & Research Centers
Biomechanics Research Unit, University of Liege (1)
Center for Education and Research on Macromolecules (CERM) (1)
Prometheus KU Leuven and Biomechanics Research Unit, U.Liege (1)
Prometheus, the KU Leuven R&D Division of Skeletal Tissue Engineering (http://www.kuleuven.be/prometheus) (1)
d‐BRU - Dental Biomaterials Research Unit - ULiège [BE] (1)
Main Referenced Disciplines
Engineering, computing & technology: Multidisciplinary, general & others (85)
Materials science & engineering (15)
Chemical engineering (8)
Food science (6)
Chemistry (6)

Publications (total 108)

The most downloaded
1050 downloads
Pyka, G., Kerckhofs, G., Papantoniou, I., Speirs, M., Schrooten, J., & Wevers, M. (2013). Surface Roughness and Morphology Customization of Additive Manufactured Open Porous Ti6Al4V Structures. Materials, 6 (10), 4737-4757. doi:10.3390/ma6104737 https://hdl.handle.net/2268/161549

The most cited

600 citations (Scopus®)

Van Bael, S., Chai, Y. C., Truscello, S., Moesen, M., Kerckhofs, G., Van Oosterwyck, H., Kruth, J.-P., & Schrooten, J. (2012). The effect of pore geometry on the in vitro biological behavior of human periosteum-derived cells seeded on selective laser-melted Ti6Al4V bone scaffolds. Acta Biomaterialia, 8 (7), 2824-34. doi:10.1016/j.actbio.2012.04.001 https://hdl.handle.net/2268/158166

Articles accepted in reviewed journal

Sadeghian Dehkord, E., Kerckhofs, G., Compère, P., Lambert, F., & Geris, L. (22 July 2023). An Empirical Model Linking Physico-Chemical Biomaterial Characteristics to Intra-Oral Bone Formation. Journal of Functional Biomaterials, 14 (7), 388. doi:10.3390/jfb14070388
Peer Reviewed verified by ORBi

Tam, W. L., Freitas Mendes, L., Chen, X., Lesage, R., Van Hoven, I., Leysen, E., Kerckhofs, G., Bosmans, K., Chai, Y. C., Yamashita, A., Tsumaki, N., Geris, L., Roberts, S. J., & Luyten, F. P. (25 September 2021). Human pluripotent stem cell-derived cartilaginous organoids promote scaffold-free healing of critical size long bone defects. Stem Cell Research and Therapy, 12 (1), 513. doi:10.1186/s13287-021-02580-7
Peer Reviewed verified by ORBi

de Bournonville, S., Geris, L., & Kerckhofs, G. (02 February 2021). Micro computed tomography with and without contrast enhancement for the characterization of microcarriers in dry and wet state. Scientific Reports, 11 (1), 2819. doi:10.1038/s41598-021-81998-8
Peer Reviewed verified by ORBi

Kamperman, T., Teixeira, L. M., Salehi, S. S., Kerckhofs, G., Guyot, Y., Geven, M., Geris, L., Grijpma, D., Blanquer, S., & Leijten, J. (07 February 2020). Engineering 3D parallelized microfluidic droplet generators with equal flow profiles by computational fluid dynamics and stereolithographic printing. Lab on a Chip, 20 (3), 490-495. doi:10.1039/c9lc00980a
Peer reviewed

Papantoniou, I., Guyot, Y., Sonnaert, M., Kerckhofs, G., Luyten, F. P., Geris, L., & Schrooten, J. (2014). Spatial optimization in perfusion bioreactors improves bone tissue-engineered construct quality attributes. Biotechnology and Bioengineering. doi:10.1002/bit.25303
Peer Reviewed verified by ORBi

Pyka, G., Kerckhofs, G., Van Bael, S., Schrooten, J., & Wevers, M. (January 2014). The effect of spatial micro-CT image resolution and surface complexity on the morphological 3D analysis of open porous structures. Materials Characterization, 87, 104-115. doi:10.1016/j.matchar.2013.11.004
Peer Reviewed verified by ORBi

Kerckhofs, G., Sainz, J., Maréchal, M., Wevers, M., Van de Putte, T., Schrooten, J., & Geris, L. (2013). Contrast-enhanced nanofocus X-ray computed tomography allows virtual 3D histopathology and morphometric analysis of osteoarthritis in small animal models. Cartilage. doi:10.1177/1947603513501175
Peer Reviewed verified by ORBi

Kerckhofs, G., Sainz, J., Wevers, M., Van de Putte, T., & Schrooten, J. (2013). Contrast-enhanced nanofocus computed tomography images the cartilage subtissue architecture in three dimensions. European Cells and Materials, 25, 179-89.
Peer reviewed

Karunratanakul, K., Kerckhofs, G., Lammens, J., Vanlauwe, J., Schrooten, J., & Van Oosterwyck, H. (2013). Validation of a finite element model of a unilateral external fixator in a rabbit tibia defect model. Medical Engineering and Physics, 35 (7), 1037-43. doi:10.1016/j.medengphy.2012.10.006
Peer Reviewed verified by ORBi

Papantoniou, I., Sonnaert, M., Geris, L., Luyten, F. P., Schrooten, J., & Kerckhofs, G. (2013). Three dimensional characterization of tissue-engineered constructs by contrast enhanced nanofocus computed tomography. Tissue Engineering. Part C, Methods. doi:10.1089/ten.tec.2013.0041
Peer Reviewed verified by ORBi

Pyka, G., Kerckhofs, G., Papantoniou, I., Speirs, M., Schrooten, J., & Wevers, M. (2013). Surface Roughness and Morphology Customization of Additive Manufactured Open Porous Ti6Al4V Structures. Materials, 6 (10), 4737-4757. doi:10.3390/ma6104737
Peer Reviewed verified by ORBi

Lambrechts, D., Roeffaers, M., Kerckhofs, G., Roberts, S. J., Hofkens, J., Van de Putte, T., Van Oosterwyck, H., & Schrooten, J. (2013). Fluorescent oxygen sensitive microbead incorporation for measuring oxygen tension in cell aggregates. Biomaterials, 34 (4), 922-9. doi:10.1016/j.biomaterials.2012.10.019
Peer Reviewed verified by ORBi

Kerckhofs, G., Pyka, G., Moesen, M., Van Bael, S., Schrooten, J., & Wevers, M. (2013). High-Resolution Microfocus X-Ray Computed Tomography for 3D Surface Roughness Measurements of Additive Manufactured Porous Materials. Advanced Engineering Materials, 15 (3), 153-158. doi:10.1002/adem.201200156
Peer Reviewed verified by ORBi

Alam, K., Kerckhofs, G., Mitrofanov, A. V., Lomov, S., Wevers, M., & Silberschmidt, V. V. (2012). On-line analysis of cracking in cortical bone under wedge penetration. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine, 226 (9), 709-17. doi:10.1177/0954411912451824
Peer Reviewed verified by ORBi

Van Bael, S., Chai, Y. C., Truscello, S., Moesen, M., Kerckhofs, G., Van Oosterwyck, H., Kruth, J.-P., & Schrooten, J. (2012). The effect of pore geometry on the in vitro biological behavior of human periosteum-derived cells seeded on selective laser-melted Ti6Al4V bone scaffolds. Acta Biomaterialia, 8 (7), 2824-34. doi:10.1016/j.actbio.2012.04.001
Peer Reviewed verified by ORBi

Chai, Y. C., Kerckhofs, G., Roberts, S. J., Van Bael, S., Schepers, E., Vleugels, J., Luyten, F. P., & Schrooten, J. (2012). Ectopic bone formation by 3D porous calcium phosphate-Ti6Al4V hybrids produced by perfusion electrodeposition. Biomaterials, 33 (16), 4044-58. doi:10.1016/j.biomaterials.2012.02.026
Peer Reviewed verified by ORBi

Pfeiffer, H., Heer, P., Pitropakis, I., Pyka, G., Kerckhofs, G., Patitsa, M., & Wevers, M. (2012). Liquid detection in confined aircraft structures based on lyotropic percolation thresholds. Sensors and Actuators. B, Chemical, 161 (1), 791-798. doi:10.1016/j.snb.2011.11.034
Peer Reviewed verified by ORBi

Truscello, S., Kerckhofs, G., Van Bael, S., Pyka, G., Schrooten, J., & Van Oosterwyck, H. (2012). Prediction of permeability of regular scaffolds for skeletal tissue engineering: a combined computational and experimental study. Acta Biomaterialia, 8 (4), 1648-58. doi:10.1016/j.actbio.2011.12.021
Peer Reviewed verified by ORBi

Chai, Y. C., Roberts, S. J., Desmet, E., Kerckhofs, G., van Gastel, N., Geris, L., Carmeliet, G., Schrooten, J., & Luyten, F. P. (2012). Mechanisms of ectopic bone formation by human osteoprogenitor cells on CaP biomaterial carriers. Biomaterials. doi:10.1016/j.biomaterials.2012.01.015
Peer Reviewed verified by ORBi

Pyka, G., Burakowski, A., Kerckhofs, G., Moesen, M., Van Bael, S., Schrooten, J., & Wevers, M. (2012). Surface Modification of Ti6Al4V Open Porous Structures Produced by Additive Manufacturing. Advanced Engineering Materials, 14 (6), 363-370. doi:10.1002/adem.201100344
Peer Reviewed verified by ORBi

Roberts, S. J., Geris, L., Kerckhofs, G., Desmet, E., Schrooten, J., & Luyten, F. P. (2011). The combined bone forming capacity of human periosteal derived cells and calcium phosphates. Biomaterials, 32 (19), 4393-405. doi:10.1016/j.biomaterials.2011.02.047
Peer Reviewed verified by ORBi

Van Bael, S., Kerckhofs, G., Moesen, M., Pyka, G., Schrooten, J., & Kruth, J. P. (2011). Micro-CT-based improvement of geometrical and mechanical controllability of selective laser melted Ti6Al4V porous structures. Materials Science and Engineering: A: Structural Materials: Properties, Microstructures and Processing, 528 (24), 7423-7431. doi:10.1016/j.msea.2011.06.045
Peer Reviewed verified by ORBi

Mendoza, F., Verboven, P., Ho, Q. T., Kerckhofs, G., Wevers, M., & Nicolai, B. (2010). Multifractal properties of pore-size distribution in apple tissue using X-ray imaging. Journal of Food Engineering, 99 (2), 206-215. doi:10.1016/j.jfoodeng.2010.02.021
Peer Reviewed verified by ORBi

Neirinck, B., Kerckhofs, G., Wevers, M., Van der Biest, O., & Vleugels, J. (2010). Morphological Analysis of Slip-Cast Emulsion-Templated Alumina Foams by Microfocus Computer Tomography. Journal of the American Ceramic Society, 93 (11), 3921-3928. doi:10.1111/j.1551-2916.2010.03964.x
Peer Reviewed verified by ORBi

Wilderjans, E., Kerckhofs, G., Lagrain, B., Brijs, K., Wevers, M., & Delcour, J. A. (2010). Baking Gradients Cause Heterogeneity in Starch and Proteins in Pound Cake. Cereal Chemistry, 87 (5), 475-480. doi:10.1094/CCHEM-05-10-0048
Peer reviewed

Pareyt, B., Talhaoui, F., Kerckhofs, G., Brijs, K., Goesaert, H., Wevers, M., & Delcour, J. A. (2009). The role of sugar and fat in sugar-snap cookies: Structural and textural properties. Journal of Food Engineering, 90 (3), 400-408. doi:10.1016/j.jfoodeng.2008.07.010
Peer Reviewed verified by ORBi

Léonard, A., Calberg, C., Kerckhofs, G., Wevers, M., Jérôme, R., Pirard, J.-P., Germain, A., & Blacher, S. (August 2008). Characterization of the porous structure of biodegradable scaffolds obtained with supercritical CO2 as foaming agent. Journal of Porous Materials, 15 (4), 397-403. doi:10.1007/s10934-006-9094-y
Peer Reviewed verified by ORBi

Verboven, P., Kerckhofs, G., Mebatsion, H. K., Ho, Q. T., Temst, K., Wevers, M., Cloetens, P., & Nicolai, B. M. (2008). Three-dimensional gas exchange pathways in pome fruit characterized by synchrotron x-ray computed tomography. Plant Physiology, 147 (2), 518-27. doi:10.1104/pp.108.118935
Peer Reviewed verified by ORBi

Kerckhofs, G., Schrooten, J., Van Cleynenbreugel, T., Lomov, S. V., & Wevers, M. (2008). Validation of x-ray microfocus computed tomography as an imaging tool for porous structures. Review of Scientific Instruments, 79 (1), 013711. doi:10.1063/1.2838584
Peer Reviewed verified by ORBi

Mendoza, F., Verboven, P., Mebatsion, H. K., Kerckhofs, G., Wevers, M., & Nicolai, B. (2007). Three-dimensional pore space quantification of apple tissue using X-ray computed microtomography. Planta, 226 (3), 559-70. doi:10.1007/s00425-007-0504-4
Peer Reviewed verified by ORBi

Blacher, S., Calberg, C., Kerckhofs, G., Léonard, A., & Wevers, M. (2006). The porous structure of biodegradable scaffolds obtained with supercritical CO2 as foaming agent. Studies in Surface Science and Catalysis, 160, 681-688.
Peer reviewed

Articles accepted in conference proceedings

Sonnaert, M., Papantoniou, I., Geris, L., Luyten, F., Schrooten, J., & Kerckhofs, G. (2013). Contrast enhanced nanoCT for 3D quantitative and spatial analysis of in vitro manufactured extracellular matrix in metallic tissue engineering scaffolds. In Abstract book User Meeting Bruker MicroCT 2013 (pp. 36-41).
Peer reviewed

Van Hove, A., Geeroms, C., Maréchal, M., Van Houdt, L., Bosmans, K., Geris, L., Luyten, F., Schrooten, J., & Kerckhofs, G. (2013). Micro-CT evaluation of the effect of material, donor and implantation site variability on the bone forming capacity of progenitor cell/CaP-collagen constructs implanted ectopically in nude mice. In Abstract book User Meeting Bruker MicroCT 2013 (pp. 122-127).
Peer reviewed

Wevers, M., Kerckhofs, G., Pyka, G., Herremans, E., Van Ende, A., Hendrickx, R., Verstrynge, E., Mariën, A., Valcke, E., & Pareyt, B. (2012). X-ray Computed Tomography for Non-Destructive Testing. In Proceedings iCT 2012.
Peer reviewed

Kerckhofs, G., Sainz, J., Wevers, M., Van de Putte, T., & Schrooten, J. (2012). Contrast-enhanced nanofocus computed tomography: a powerful technique enabling the combined visualization of the tissue architecture of cartilage and bone. In Abstract book User Meeting Bruker MicroCT 2012.
Peer reviewed

Geeroms, C., Bosmans, K., Maréchal, M., Roberts, S. J., Kerckhofs, G., & Schrooten, J. (2012). Micro-CT as an evaluation tool for first line screening of the bone forming capacity of human periosteum-derived cells in nude mice. In Abstract book User Meeting Bruker MicroCT 2012.
Peer reviewed

Vanaerschot, A., Cox, B., Blacklock, M., Kerckhofs, G., Wevers, M., Lomov, S. V., & Vandepitte, D. (2012). Statistical description of the internal geometry of a polymer textile composite using micro-computed tomography. In Proceedings book European Conference on Composite Materials 2012.
Peer reviewed

Kerckhofs, G., Pyka, G., Moesen, M., Schrooten, J., & Wevers, M. (2012). High-resolution micro-CT as a tool for 3D surface roughness measurement of 3D additive manufactured porous structures. In Proceedings iCT 2012 (pp. 77-83).
Peer reviewed

Pyka, G., Kerckhofs, G., Van Bael, S., Velasco Martin, E., Moesen, M., Schrooten, J., & Wevers, M. (2011). Characterisation of meso-and micro-scale morphological and mechanical properties of surface modified 3D Ti6Al4V open porous structures. In Proceedings of MetFoam 2011.
Peer reviewed

Kerckhofs, G., Roberts, S. J., Wevers, M., Luyten, F., & Schrooten, J. (2011). Micro-CT: a powerful tool for the characterization and evaluation of the bone formatting capacity of calcium phosphate–stem cells tissue engineering constructs. In Abstract book SkyScan User Meeting 2011.
Peer reviewed

Kerckhofs, G., Pyka, G., Moesen, M., Van Bael, S., Schrooten, J., & Wevers, M. (2011). Novel high-resolution micro-CT based surface roughness measurement protocol for complex porous structures. In Proceedings MetFoam 2011, Hur, B., Kim, S., Hyun, S. (Eds.).
Peer reviewed

Truscello, S., Kerckhofs, G., Moesen, M., Torcasio, A., Van Bael, S., van Lenthe, H., Schrooten, J., & Van Oosterwyck, H. (2011). CAD versus micro-CT based models of Ti6Al4V scaffolds for bone tissue engineering: a solid and fluid mechanical analysis. In Proceedings of II International Conference on Tissue Engineering (pp. 1-7).
Peer reviewed

Pontikes, Y., Kerckhofs, G., Kim, U., Rathossi, C., Mertens, G., Cho, W.-S., Wevers, M., & Blanpain, B. (2011). Microstructure, crystalline phases and pore morphology of Onggi. In Proceedings ECerS XII.
Peer reviewed

Truscello, S., Kerckhofs, G., Moesen, M., Torcasio, A., Van Bael, S., van Lenthe, H., Schrooten, J., & Van Oosterwyck, H. (2011). A computational solid and fluid mechanical analysis of CAD-versus micro-CT-based models of regular Ti6Al4V scaffolds for bone tissue engineering. In Histology and Histopathology.
Peer reviewed

Pyka, G., Kerckhofs, G., Chai, Y. C., Moesen, M., Martin, E., Schrooten, J., & Wevers, M. (2011). The use of micro-CT to correlate in-vitro cell behaviour with the surface roughness of Ti6Al4V scaffolds for tissue engineering. In Abstract book SkyScan User Meeting 2011.
Peer reviewed

Verboven, P., Ho, Q. T., Herremans, E., Mebatsion, H. K., Nicolai, B., Kerckhofs, G., Wevers, M., & Cloetens, P. (2011). Fruit Microstructure Evaluation Using Synchrotron X-Ray Computed Tomography. In Ajjguilera, JM BarbosaCanovas, GV Simpson, R WeltiChanes, J BermudezAguirre, D (Ed.), FOOD ENGINEERING INTERFACES (pp. 589-598). New York, United States - New York: Springer. doi:10.1007/978-1-4419-7475-4_24
Peer reviewed

Kerckhofs, G., Geris, L., Roberts, S., Braem, A., Wevers, M., Luyten, F., & Schrooten, J. (2011). Microfocus X-ray computed tomography based characterization of calcium phosphate–stem cells constructs combined with empirical modelling as a tool for the prediction of bone formation. In Histology and Histopathology.
Peer reviewed

Lambrechts, D., Kerckhofs, G., Roberts, S., Van de Putte, T., Van Oosterwyck, H., & Schrooten, J. (2011). Fluorescent microparticle incorporation in chondrogenic cell aggregates to monitor local oxygen tension. In Histology and Histopathology.
Peer reviewed

Pyka, G., Kerckhofs, G., Pauwels, B., Schrooten, J., & Wevers, M. (2011). X-rays nanotomography in a scanning electron microscope–capabilities and limitations for materials research. In Abstract book SkyScan User Meeting 2011.
Peer reviewed

Pyka, G., Kerckhofs, G., Van Bael, S., Moesen, M., Loeckx, D., Schrooten, J., & Wevers, M. (2010). Non-destructive characterisation of the influence of surface modification on the morphology and mechanical behaviour of rapid prototyped Ti6Al4v bone tissue engineering scaffolds. In Proceedings book ECNDT 2010 (pp. 7-11).
Peer reviewed

Kerckhofs, G., Pyka, G., Braem, A., Mattheys, T., Schrooten, J., & Wevers, M. (2010). Novel high-resolution micro-CT based surface roughness measurement protocol for complex porous structures. In Proceedings CellMat 2010.
Peer reviewed

Kerckhofs, G., Pyka, G., Loeckx, D., Van Bael, S., Schrooten, J., & Wevers, M. (2010). The combined use of micro-CT imaging, in-situ loading and non-rigid image registration for 3D experimental local strain mapping on porous bone tissue engineering scaffolds under compressive loading. In Proceedings book ECNDT 2010.
Peer reviewed

Kerckhofs, G., Pyka, G., Van Bael, S., Schrooten, J., & Wevers, M. (2010). Investigation of the influence of surface roughness modification of bone tissue engineering scaffolds. In Abstract book SkyScan User Meeting 2010.
Peer reviewed

Pyka, G., Kerckhofs, G., Braem, A., Mattheys, T., Schrooten, J., & Wevers, M. (2010). Novel micro-ct based characterization tool for surface roughness measurements of porous structures. In Abstract book SkyScan User Meeting 2010.
Peer reviewed

Hendrickx, R., Bruyninckx, K., Schueremans, L., Kerckhofs, G., Verstrynge, E., Wevers, M., & Van Balen, K. (2010). Observation of the failure mechanism of brick masonry doublets with cement and lime mortars by microfocus X-ray computed tomography. In Jäger, W., Hasseltine, B., Fried, A. (Eds.), 8th International Masonry Conference 2010.
Peer reviewed

Pyka, G., Kerckhofs, G., Van Bael, S., Moesen, M., Loeckx, D., Schrooten, J., & Wevers, M. (2010). Characterisation of the influence of surface modification on the morphology and the mechanical behavior of rapid prototyped porous structures for tissue engineering applications. In Proceedings CellMat 2010.
Peer reviewed

Kerckhofs, G., Moesen, M., Loeckx, D., Van Bael, S., Pyka, G., Maes, F., Wevers, M., & Schrooten, J. (2009). Experimental quantification of the local strains in bone TE scaffolds by the combined use of micro-CT imaging, in-situ loading and local strain mapping. In Proc. ECCOMAS - International Conference on Tissue Engineering 2009. . 2009, Bártolo, P. (Eds.).
Peer reviewed

Moesen, M., Kerckhofs, G., Van Bael, S., Lomov, S. V., Verpoest, I., & Schrooten, J. (2009). Implicit surface-based design of regular bone scaffolds. In Proc. ECCOMAS - International Conference on Tissue Engineering 2009. . 2009, Bártolo, P. (Eds.).
Peer reviewed

Van Bael, S., Vandenbroucke, B., Kerckhofs, G., Schrooten, J., & Kruth, J.-P. (2009). Design and production of bone scaffolds with selective laser melting. In TMS 2009 138TH ANNUAL MEETING & EXHIBITION - SUPPLEMENTAL PROCEEDINGS, VOL 1: MATERIALS PROCESSING AND PROPERTIES (pp. 333-339). Warrendale, United States - Pennsylvania: Minerals, Metals & Materials Soc.
Peer reviewed

Kerckhofs, G., Van Bael, S., Moesen, M., Maes, F., Loeckx, D., Schrooten, J., & Wevers, M. (2009). Novel micro-CT based local strain mapping tool to characterize the failure modes of bone tissue engineering scaffolds. In Abstract book SkyScan User Meeting 2009.
Peer reviewed

Van Bael, S., Kerckhofs, G., Moesen, M., Kruth, J.-P., & Schrooten, J. (2009). Morphological and mechanical characterization of Ti6Al4V scaffolds produced with selective laser melting. In Proc. ECCOMAS - International Conference on Tissue Engineering 2009. . 2009, Bártolo, P. (Eds.).
Peer reviewed

Kerckhofs, G., Neirinck, B., Van Cleynenbreugel, T., Wevers, M., Schepers, E., & Schrooten, J. (2008). Validation of micro-CT as an imaging tool for the quantification of bone formation in and around bone tissue engineering scaffolds. In Abstract book SkyScan User Meeting 2008.
Peer reviewed

Verboven, P., Kerckhofs, G., Cloetens, P., Mebatsion, H., Mendoza, F., Wevers, M., & Nicolaï, B. (2008). High resolution 3-D imaging of void networks in plant tissues. In Abstract book SkyScan User Meeting 2008 (pp. 53).
Peer reviewed

Kerckhofs, G., Schrooten, J., Lomov, S. V., & Wevers, M. (2008). The spatial resolution dependency of a micro-CT thresholding method based on the correspondence with microscopic images. In Abstract book International Conference on Computational and Experimental Science and Engineering 2008.
Peer reviewed

Kerckhofs, G., Schrooten, J., Elicegui, L., Van Bael, S., Moesen, M., Lomov, S. V., & Wevers, M. (2008). Mechanical characterization of porous structures by the combined use of micro-CT and in-situ loading. In Proceedings book WCNDT 2008.
Peer reviewed

Kerckhofs, G., Schrooten, J., Elicegui, L., Van Bael, S., Loeckx, D., Maes, F., & Wevers, M. (2008). Mechanical quantification of porous structures by the combined use of micro-CT and in-situ loading. In Proceedings book WCNDT 2008.
Peer reviewed

Kerckhofs, G., Schrooten, J., Van Cleynenbreugel, T., Lomov, S. V., & Wevers, M. (2007). Validation of micro-CT: experimental protocol for porous structures. In Abstract book SkyScan User Meeting 2007.
Peer reviewed

Verboven, P., Kerckhofs, G., Mebatsion, H. K., Mendoza, F., Temst, K., Wevers, M., Cloetens, P., & Nicolaï, B. M. (2007). Comparison of different X-ray computed tomography techniques for the quantitative characterisation of the 3D microstructure of pear fruit tissue. In Proceedings: Busse, G., Van Hemelrijck, D., Solodov, I., Anastasopoulos, A. (Eds.).
Peer reviewed

Blacher, S., Calberg, C., Kerckhofs, G., Léonard, A., Wevers, M., Jérôme, R., & Pirard, J.-P. (2006). The porous structure of biodegradable scaffolds obtained with supercritical CO(2) as foaming agent. Studies in Surface Science and Catalysis, 160, 681-688.
Peer reviewed

Kerckhofs, G., Schrooten, J., Wevers, M., Van Marcke, P., & Van Cleynenbreugel, T. (2006). Standardisation and Validation of Micro-CT for the Morphological Characterisation of Porous Structures. In Proceedings book ECNDT 2006 (pp. 25-29).
Peer reviewed

Blacher, S., Kerckhofs, G., Caliberg, C., Léonard, A., Wevers, M., Pirard, J.-P., & Germain, A. (2005). X-ray microtomography coupled with image analysis: a useful tool for 3D characterization of polymer foams. In Proceedings of Imageries et polymères 2005.
Peer reviewed

Kerckhofs, G., Wevers, M., & Schrooten, J. (2005). Morphological and mechanical characterization of porous structures with micro-CT. In Abstract book SkyScan User Meeting 2005.
Peer reviewed

Contact ORBi