Reference : Seismic-induced fire resistance of composite welded beam-to-column joints with concrete-...
Scientific journals : Article
Engineering, computing & technology : Civil engineering
http://hdl.handle.net/2268/97733
Seismic-induced fire resistance of composite welded beam-to-column joints with concrete-filled tubes
English
Pucinotti, Raffaele mailto [Mediterranean University of Regio Calabria, Italy > Dept. of Mechanics and Materials > > >]
Bursi, Oreste mailto [Trento University, Italy > Dept. of Mechanical and Structural Engineering > > >]
Franssen, Jean-Marc mailto [Université de Liège - ULg > Département Argenco : Secteur SE > Ingénierie du feu >]
Lennon, Tom mailto [Building Research Establishment Ltd, UK > > > >]
2011
Fire Safety Journal
Elsevier Science
46
335-347
Yes (verified by ORBi)
International
0379-7112
Oxford
United Kingdom
[en] Performance-based engineering ; Fire ; Seismic ; steel-concrete composite ; beam-to-column joint ; welded connection ; concrete-filled tube ; CFSS
[en] Major earthquakes in urban areas have often been followed by significant fires that cause extensive damage to property. Therefore, a seismic-induced fire is a scenario that should be addressed properly in performance-based engineering. In this paper, numerical and experimental results of welded steel–concrete composite full-strength beam-to-column joints under post-earthquake fires are described.
This was part of a European project aimed at developing fundamental data and prequalification design guidelines of ductile and fire-resistant composite beam-to-column joints with concrete-filled tubes. In detail, seismic and fire analyses were used to design moment-resisting frames endowed with the proposed joint typology. A total of six specimens were designed and subjected to both monotonic and cyclic lateral loads. The specimens were subassemblages of beam-to-column joints, and performed well. Since the scope of the project was to promote joint typologies able to survive a seismic-induced fire, some specimens were pre-damaged before being subjected to fire loadings by imposing monotonic loads equivalent to damage levels induced by seismic loadings. Thus, after fire testing, valuable information about the performance of the proposed joint typology was obtained, and the adequacy of the concurrent seismic and fire design was demonstrated.
European Union, Research Fund for Coal and Steel
PRECIOUS (Prefabricated composite beam-to-concrete filled tubes or partially reinforced-concrete-Encased Column connections for severe seismic and fire loadings
Researchers ; Professionals
http://hdl.handle.net/2268/97733
10.1016/j.firesaf.2011.05.003

File(s) associated to this reference

Fulltext file(s):

FileCommentaryVersionSizeAccess
Open access
2011 seismic induced fire resistance of welded tubes - FSJ.fdfAuthor postprint2.11 MBView/Open

Bookmark and Share SFX Query