Reference : Non-invasive assessment of airway responsiveness in healthy and allergen-sensitised c...
Scientific journals : Article
Life sciences : Veterinary medicine & animal health
http://hdl.handle.net/2268/9017
Non-invasive assessment of airway responsiveness in healthy and allergen-sensitised cats by use of barometric whole body plethysmography
English
Kirschvink, N. [> > > >]
Leemans, Jérôme mailto [Université de Liège - ULg > Département de sciences fonctionnelles > Pharmacologie, pharmacothérapie et toxicologie >]
Delvaux, François [> >]
Snaps, Frédéric [Université de Liège - ULg > Département clinique des animaux de compagnie et des équidés > Imagerie médicale >]
Clercx, Cécile mailto [Université de Liège - ULg > Département clinique des animaux de compagnie et des équidés > Pathologie médicale des petits animaux >]
Gustin, Pascal mailto [Université de Liège - ULg > Département de sciences fonctionnelles > Pharmacologie, pharmacothérapie et toxicologie >]
2007
Veterinary Journal
Elsevier Sci Ltd
173
2
343-352
Yes (verified by ORBi)
International
1090-0233
Oxford
[en] feline ; bronchial responsiveness ; age ; inflammation ; bronchodilator
[en] This study aimed at determining whether airway responsiveness (AR) tests performed by use of barometric whole body plethysmography (BWBP) were repeatable in cats and to what extent AR was affected by the nebulization protocol used, the age of the animals, the inflammatory status of the airways and prior bronchodilator treatment. Repeatability of AR was tested on two occasions in 30 healthy cats. The concentration of carbachol inducing a 300% increase of the enhanced pause (Penh) - an estimator of airflow limitation - was calculated (C-Penh300) and did not differ significantly between the two tests (0.035 +/- 0.017% compared to 0.034 +/- 0.016%) and was significantly and positively correlated. The comparison between rapidly and slowly increasing carbachol concentrations was performed in ten healthy cats and showed a significantly lower C-Penh300 (%) when slowly increasing concentrations were used (0.037 +/- 0.013% compared to 0.039 +/- 10.015%, P < 0.05). A significant age-related increase of C-Penh300 was evidenced by performing AR tests in 15 healthy cats at 12, 18, 24 and 30 months (12 months: 0.026 +/- 0.008%, 18 months: 0.031 +/- 0.009%, 24 months: 0.038 +/- 0.01%, 30 months: 0.043 +/- 0.014%, P < 0.05). C-Penh300 significantly decreased in 12 Ascaris suum-sensitised cats after allergen exposure (0.026 +/- 0.016% compared to 0.033 +/- 0.016%, P < 0.05) and was negatively correlated with the granulocyte percentage of bronchoalveolar lavage fluid (r = -0.36, P < 0.01). Compared with a placebo inhalation, pretreatment with inhaled salbutamol significantly increased C-Penh300 in four healthy cats (0.093 +/- 0.021% compared to 0.036 +/- 0.004%, P < 0.05). This study provides evidence that AR determination by use of BWBP is promising as non-invasive indicator of lower airway inflammation or for monitoring response to bronchodilator treatment. (c) 2005 Elsevier Ltd. All rights reserved.
Researchers ; Professionals
http://hdl.handle.net/2268/9017
10.1016/j.tvjl.2005.10.007

File(s) associated to this reference

Fulltext file(s):

FileCommentaryVersionSizeAccess
Restricted access
KirschvinkN_TheVetJ_2007.pdfPublisher postprint180.3 kBRequest copy

Bookmark and Share SFX Query

All documents in ORBi are protected by a user license.