Liquid chromatographic determination of enrofloxacin in nasal secretions and plasma of healthy pigs using restricted access material for on-line sample clean-up
English
Bimazubute, M. A. [> > > >]
Rozet, Eric mailto [Université de Liège - ULg > Département de pharmacie > Chimie analytique >]
Dizier, Isabelle [Université de Liège - ULg > Département des maladies infectieuses et parasitaires > Bactériologie et pathologie des maladies bactériennes >]
Gustin, Pascal mailto [Université de Liège - ULg > Département de sciences fonctionnelles > Pharmacologie, pharmacothérapie et toxicologie >]
Hubert, Philippe mailto [Université de Liège - ULg > Département de pharmacie > Chimie analytique >]
Crommen, Jacques mailto [Université de Liège - ULg > Département de pharmacie > Analyse des médicaments >]
Chiap, Patrice [Centre Hospitalier Universitaire de Liège - CHU > > Pharmacologie clinique >]
2008
Journal of Chromatography. A
Elsevier Science
1189
1-2
456-466
Yes (verified by ORBi)
International
0021-9673
Amsterdam
The Netherlands
[en] Enrofloxacin ; Nasal secretions ; Plasma ; Restricted access material ; Column-switching ; Healthy pigs ; Validation
[en] A new fully automated method was developed for the quantitative analysis of an antibacterial drug, enrofloxacin (ENRO), in both nasal secretions and plasma samples of healthy pigs. The method is based on the use of a pre-column packed with restricted access material (RAM), namely RP-18 ADS (alkyl diol silica), for on-line sample clean-up coupled to a liquid chromatographic (LC) column containing octadecyl silica. The only off-line sample preparation was the 50-fold dilution of nasal secretions and plasma samples in the washing liquid composed of 25 mM phosphate buffer of pH 7.4. A 10 μl diluted sample volume was injected directly onto the pre-column and washed for 7 min. By rotation of a switching valve, the analyte of interest was eluted in the back-flush mode with the LC mobile phase which consisted in a mixture of 25 mM phosphate buffer of pH 3.0 and acetonitrile according to a segmented gradient elution. By a new rotation of the switching valve, the pre-column and the analytical column were equilibrated for 3 min with the initial mobile phases. The flow-rate was 0.8 ml min−1 for the washing liquid and 1.5 ml min−1 for the LC mobile phase. ENRO was detected by fluorescence at excitation and emission wavelengths of 278 and 445 nm, respectively. Finally, the developed method was validated using an original strategy based on total measurement error and accuracy profiles as a decision tool. The limits of quantitation of ENRO in plasma and in nasal secretions were 30.5 and 91.6 ng/ml, respectively. The validated method was then applied successfully to the determination of ENRO in healthy pigs treated by intramuscular injection at different doses (2.5, 10 and 30 mg/kg bodyweight) for a pilot study. This method could be also used for the simultaneous analysis of ENRO and its main metabolite, ciprofloxacin (CIPRO).
Researchers ; Professionals
http://hdl.handle.net/2268/8569

File(s) associated to this reference

Fulltext file(s):

FileCommentaryVersionSizeAccess
Restricted access
BimazubuteMA_JChromatoA_2008.pdfNo commentaryPublisher postprint997.51 kBRequest copy

Bookmark and Share SFX Query

All documents in ORBi are protected by a user license.