Article (Scientific journals)
A Strategy for Multiple Immunophenotyping by Image Cytometry: Model Studies Using Latex Microbeads Labeled with Seven Streptavidin-Bound Fluorochromes
Gothot, André; Grosdent, Jean-Claude; Paulus, Jean-Michel
1996In Cytometry, 24 (3), p. 214-25
Peer Reviewed verified by ORBi
 

Files


Full Text
Gothot 1996.pdf
Publisher postprint (1.15 MB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Abstract :
[en] Multiple immunophenotyping is aimed at identifying several cell populations in a single labeling procedure by their ability to bind combinations of specific labeled antibodies. The present work demonstrates the simultaneous discrimination by using image cytometry of aminomethylcoumarin acetate (AMCA), Lucifer yellow (LY), fluorescein isothiocyanate (FITC), R-phycoerythrin (PE), PE-Texas red tandem (Red613), peridinin-chlorophyll protein (PerCP), and allophycocyanin (APC), which were all bound to latex beads as streptavidin-conjugated fluorochromes. This has been the result of a step-by-step optimization of the several factors affecting the sensitivity and specificity of multiple immunofluorescence analysis. First, 14 streptavidin-conjugated fluorochromes were evaluated by using spectrofluorometry. A primary selection was then made of ten spectrally separable dyes that could be evaluated by using image cytometry. These dyes were bound to latex particles, and specific filter combinations were assembled to minimize crosstalk between fluorophores while preserving sufficient fluorescence intensity and counting statistics. Potential probe associations were then assessed by measuring the emissions of all fluorochromes that were detected by each filter combination. The resulting crosstalk matrix served as the basic tool both for final selection of the optimal filter combination and for dye set (composed, in this case, of the seven fluorochromes described above) and for mathematical correction of residual spectral overlap. Next, an image cytometry system was adapted to collect seven images of matched brightness with the selected combination of excitation/emission filters and dichroic mirrors. Finally, seven-parameter synthetic images were generated by digital image processing.
Disciplines :
Hematology
Author, co-author :
Gothot, André ;  Université de Liège - ULiège > Département des sciences cliniques > Département des sciences cliniques
Grosdent, Jean-Claude ;  Centre Hospitalier Universitaire de Liège - CHU > Hématologie biologique et immuno hématologie
Paulus, Jean-Michel ;  Université de Liège - ULiège > Services généraux (Faculté de médecine) > Relations académiques et scientifiques (Médecine)
Language :
English
Title :
A Strategy for Multiple Immunophenotyping by Image Cytometry: Model Studies Using Latex Microbeads Labeled with Seven Streptavidin-Bound Fluorochromes
Publication date :
01 July 1996
Journal title :
Cytometry
ISSN :
0196-4763
eISSN :
1097-0320
Publisher :
John Wiley & Sons, Hoboken, United States - New Jersey
Volume :
24
Issue :
3
Pages :
214-25
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 17 February 2011

Statistics


Number of views
74 (3 by ULiège)
Number of downloads
268 (4 by ULiège)

Scopus citations®
 
12
Scopus citations®
without self-citations
11
OpenCitations
 
5

Bibliography


Similar publications



Contact ORBi