Subject-specific cardiovascular system model-based identification and diagnosis of septic shock with a minimally invasive data set: animal experiments and proof of concept.
[en] A cardiovascular system (CVS) model and parameter identification method have previously been validated for identifying different cardiac and circulatory dysfunctions in simulation and using porcine models of pulmonary embolism, hypovolemia with PEEP titrations and induced endotoxic shock. However, these studies required both left and right heart catheters to collect the data required for subject-specific monitoring and diagnosis-a maximally invasive data set in a critical care setting although it does occur in practice. Hence, use of this model-based diagnostic would require significant additional invasive sensors for some subjects, which is unacceptable in some, if not all, cases. The main goal of this study is to prove the concept of using only measurements from one side of the heart (right) in a 'minimal' data set to identify an effective patient-specific model that can capture key clinical trends in endotoxic shock. This research extends existing methods to a reduced and minimal data set requiring only a single catheter and reducing the risk of infection and other complications-a very common, typical situation in critical care patients, particularly after cardiac surgery. The extended methods and assumptions that found it are developed and presented in a case study for the patient-specific parameter identification of pig-specific parameters in an animal model of induced endotoxic shock. This case study is used to define the impact of this minimal data set on the quality and accuracy of the model application for monitoring, detecting and diagnosing septic shock. Six anesthetized healthy pigs weighing 20-30 kg received a 0.5 mg kg(-1) endotoxin infusion over a period of 30 min from T0 to T30. For this research, only right heart measurements were obtained. Errors for the identified model are within 8% when the model is identified from data, re-simulated and then compared to the experimentally measured data, including measurements not used in the identification process for validation. Importantly, all identified parameter trends match physiologically and clinically and experimentally expected changes, indicating that no diagnostic power is lost. This work represents a further with human subjects validation for this model-based approach to cardiovascular diagnosis and therapy guidance in monitoring endotoxic disease states. The results and methods obtained can be readily extended from this case study to the other animal model results presented previously. Overall, these results provide further support for prospective, proof of concept clinical testing with humans.
Ghuysen, Alexandre ; Université de Liège - ULiège > Département des sciences de la santé publique > Réanimation - Urgence extrahospitalière
Kolh, Philippe ; Université de Liège - ULiège > Département des sciences biomédicales et précliniques > Biochimie et physiologie générales, humaines et path.
Dauby, Pierre ; Université de Liège - ULiège > Département d'astrophys., géophysique et océanographie (AGO) > Thermodynamique des phénomènes irréversibles
Desaive, Thomas ; Université de Liège - ULiège > Département d'astrophys., géophysique et océanographie (AGO) > Thermodynamique des phénomènes irréversibles - Département d'astrophys., géophysique et océanographie (AGO)
Language :
English
Title :
Subject-specific cardiovascular system model-based identification and diagnosis of septic shock with a minimally invasive data set: animal experiments and proof of concept.
Angus D C and Crowther M A 2003 Unraveling severe sepsis: why did OPTIMIST fail and what's next? JAMA 290 256-8
Angus D C et al 2001 Epidemiology of severe sepsis in the United States: analysis of incidence, outcome, and associated costs of care Crit. Care Med. 29 1303-10
Annane D, Bellissant E and Cavaillon J-M 2005 Septic shock Lancet 365 63-78
Baan J et al 1984 Continuous measurement of left ventricular volume in animals and humans by conductance catheter Circulation 70 812-23 (Pubitemid 15205446)
Baselli G et al 1986 Spectral and cross-spectral analysis of heart rate and arterial blood pressure variability signals Comput. Biomed. Res. 19 520-34
Baselli G et al 1988 Cardiovascular variability signals: towards the identification of a closed-loop model of the neural control mechanisms IEEE Trans. Biomed. Eng. 35 1033-46
Baselli G et al 1994 Model for the assessment of heart period and arterial pressure variability interactions and of respiration influences Med. Biol. Eng. Comput. 32 143-52
Bridges E J and Dukes S 2005 Cardiovascular aspects of septic shock: pathophysiology, monitoring, and treatment Crit Care Nurse 25 18-20
Burkhoff D et al 1985 Accuracy of volume measurement by conductance catheter in isolated, ejecting canine hearts Circulation 72 440-7
Chung D C et al 1997 A dynamic model of ventricular interaction and pericardial influence Am. J. Physiol. 272 H2942-62
Dellinger R P 2003 Cardiovascular management of septic shock Crit. Care Med. 31 946-55
Desaive T et al 2008 Cardiovascular modelling and identification in septic shock-experimental validation Proc. 17th IFAC World Congress (IFAC WC2008) (Seoul, Korea, 6-11 July 2008) DVD pp 8068-73
Guyton A C and Hall J E 2000 Textbook of Medical Physiology 10th edn (Philadelphia, PA: Saunders) pp xxxii, 1064
Kumar A et al 2004 Preload-independent mechanisms contribute to increased stroke volume following large volume saline infusion in normal volunteers: a prospective interventional study Crit. Care 8 R128-36
Lambermont B et al 2003 Effects of endotoxic shock on right ventricular systolic function and mechanical efficiency Cardiovasc Res. 59 412-8
Olansen J B et al 2000 A closed-loop model of the canine cardiovascular system that includes ventricular interaction Comput. Biomed. Res. 33 260-95
Pagani M et al 1986 Power spectral analysis of heart rate and arterial pressure variabilities as a marker of sympathovagal interaction in man and conscious dog Circ. Res. 59 178-93
Smith B W 2004 Minimal haemodynamic modelling of the heart & circulation for clinical application PhD Thesis University of Canterbury, Christchurch, New Zealand http://hdl.handle.net/10092/4645
Smith B W et al 2004 Minimal haemodynamic system model including ventricular interaction and valve dynamics Med. Eng. Phys. 26 131-9
Starfinger C 2008 Patient-specific modelling of the cardiovascular system for diagnosis and therapy assistance in critical care PhD Thesis University of Canterbury, Christchurch, New Zealand http://hdl.handle.net/10092/1718
Starfinger C et al 2007 Model-based cardiac diagnosis of pulmonary embolism Comput. Methods Programs Biomed. 87 46-60
Starfinger C et al 2008a Model-based identification and diagnosis of a porcine model of induced endotoxic shock with hemofiltration Math Biosci. 216 132-9
Starfinger C et al 2008b Prediction of hemodynamic changes towards PEEP titrations at different volemic levels using a minimal cardiovascular model Comput. Methods Programs Biomed. 91 128-34
Starfinger C et al 2008c Model-based identification of PEEP titrations during different volemic levels Comput. Methods Programs Biomed. 91 135-44
Task Force of the American College of Critical Care Medicine, S.o. C. C. M. 1999 Practice parameters for hemodynamic support of sepsis in adult patients in sepsis Crit. Care Med. 27 639-60
van der Kooi T I I et al 2007 Incidence and risk factors of device-associated infections and associated mortality at the intensive care in the Dutch surveillance system Intensive Care Med. 33 271-8