Article (Scientific journals)
Subject-specific cardiovascular system model-based identification and diagnosis of septic shock with a minimally invasive data set: animal experiments and proof of concept.
Chase, J Geoffrey; Lambermont, Bernard; Starfinger, Christina et al.
2011In Physiological Measurement, 32 (1), p. 65-82
Peer Reviewed verified by ORBi
 

Files


Full Text
septic_shock_RV_measurements-revised2-final.pdf
Author postprint (209.37 kB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Abstract :
[en] A cardiovascular system (CVS) model and parameter identification method have previously been validated for identifying different cardiac and circulatory dysfunctions in simulation and using porcine models of pulmonary embolism, hypovolemia with PEEP titrations and induced endotoxic shock. However, these studies required both left and right heart catheters to collect the data required for subject-specific monitoring and diagnosis-a maximally invasive data set in a critical care setting although it does occur in practice. Hence, use of this model-based diagnostic would require significant additional invasive sensors for some subjects, which is unacceptable in some, if not all, cases. The main goal of this study is to prove the concept of using only measurements from one side of the heart (right) in a 'minimal' data set to identify an effective patient-specific model that can capture key clinical trends in endotoxic shock. This research extends existing methods to a reduced and minimal data set requiring only a single catheter and reducing the risk of infection and other complications-a very common, typical situation in critical care patients, particularly after cardiac surgery. The extended methods and assumptions that found it are developed and presented in a case study for the patient-specific parameter identification of pig-specific parameters in an animal model of induced endotoxic shock. This case study is used to define the impact of this minimal data set on the quality and accuracy of the model application for monitoring, detecting and diagnosing septic shock. Six anesthetized healthy pigs weighing 20-30 kg received a 0.5 mg kg(-1) endotoxin infusion over a period of 30 min from T0 to T30. For this research, only right heart measurements were obtained. Errors for the identified model are within 8% when the model is identified from data, re-simulated and then compared to the experimentally measured data, including measurements not used in the identification process for validation. Importantly, all identified parameter trends match physiologically and clinically and experimentally expected changes, indicating that no diagnostic power is lost. This work represents a further with human subjects validation for this model-based approach to cardiovascular diagnosis and therapy guidance in monitoring endotoxic disease states. The results and methods obtained can be readily extended from this case study to the other animal model results presented previously. Overall, these results provide further support for prospective, proof of concept clinical testing with humans.
Disciplines :
Cardiovascular & respiratory systems
Author, co-author :
Chase, J Geoffrey
Lambermont, Bernard  ;  Université de Liège - ULiège > Frais communs médecine
Starfinger, Christina
Hann, Christopher E
Shaw, Geoffrey M
Ghuysen, Alexandre ;  Université de Liège - ULiège > Département des sciences de la santé publique > Réanimation - Urgence extrahospitalière
Kolh, Philippe  ;  Université de Liège - ULiège > Département des sciences biomédicales et précliniques > Biochimie et physiologie générales, humaines et path.
Dauby, Pierre  ;  Université de Liège - ULiège > Département d'astrophys., géophysique et océanographie (AGO) > Thermodynamique des phénomènes irréversibles
Desaive, Thomas  ;  Université de Liège - ULiège > Département d'astrophys., géophysique et océanographie (AGO) > Thermodynamique des phénomènes irréversibles - Département d'astrophys., géophysique et océanographie (AGO)
Language :
English
Title :
Subject-specific cardiovascular system model-based identification and diagnosis of septic shock with a minimally invasive data set: animal experiments and proof of concept.
Publication date :
2011
Journal title :
Physiological Measurement
ISSN :
0967-3334
Publisher :
Institute of Physics, Bristol, United Kingdom
Volume :
32
Issue :
1
Pages :
65-82
Peer reviewed :
Peer Reviewed verified by ORBi