No full text
Unpublished conference/Abstract (Scientific congresses and symposiums)
Image Quality evaluation for 124I in the microPET Focus 120 scanner using the NEMA NU4-2008 phantom
Bahri, Mohamed Ali; Warnock, Geoffrey; Taleb, Dounia et al.
2011Hot Topics in Molecular Imaging 2011 (TOPIM 2011) - The 5th Winter Conference of the European Society for Molecular Imaging
 

Files


Full Text
No document available.

Send to



Details



Keywords :
PET; microPET; Focus 120; Iodine-124; NEMA; NU4-2008; Image quality
Abstract :
[en] Physical properties of iodine-124 such as its high positron energy, corresponding large positron range in tissue and the fraction of the single γ-photons emitted may have detrimental effects on the PET image quality. The purpose of this work was to evaluate the image quality for iodine-124 in the small animal microPET Focus 120 scanner using the NEMA NU4-2008 image quality phantom. Although the 2 ns timing window gives higher recovery coefficients and slightly lower spill-over ratios and combined with the 350-590 keV energy window gives the lowest spill-over ratio, the combination of the 350-650 keV and 6 ns windows seems to be the best compromise to obtain images with high contrast and low noise content.
Disciplines :
Radiology, nuclear medicine & imaging
Author, co-author :
Bahri, Mohamed Ali  ;  Université de Liège - ULiège > Centre de recherches du cyclotron
Warnock, Geoffrey ;  Université de Liège - ULiège > Centre de recherches du cyclotron
Taleb, Dounia ;  Université de Liège - ULiège > Département de physique > Imagerie médicale expérimentale
Plenevaux, Alain  ;  Université de Liège - ULiège > Centre de recherches du cyclotron
Luxen, André ;  Université de Liège - ULiège > Département de chimie (sciences) > Chimie organique de synthèse - Centre de recherches du cyclotron
Salmon, Eric  ;  Université de Liège - ULiège > Département des sciences cliniques > Neuroimagerie des troubles de la mémoire et révalid. cogn.
Seret, Alain ;  Université de Liège - ULiège > Département de physique > Imagerie médicale expérimentale
Language :
English
Title :
Image Quality evaluation for 124I in the microPET Focus 120 scanner using the NEMA NU4-2008 phantom
Publication date :
17 January 2011
Event name :
Hot Topics in Molecular Imaging 2011 (TOPIM 2011) - The 5th Winter Conference of the European Society for Molecular Imaging
Event organizer :
European Society for Molecular Imaging
Event place :
Les Houches, France
Event date :
January 16-21, 2011
Audience :
International
Funders :
F.R.S.-FNRS - Fonds de la Recherche Scientifique [BE]
Available on ORBi :
since 24 January 2011

Statistics


Number of views
144 (5 by ULiège)
Number of downloads
0 (0 by ULiège)

Bibliography


Similar publications



Contact ORBi