Reference : 3D simulation of Industrial Hall in case of fire. Benchmark between ABAQUS, ANSYS and SA...
Scientific congresses and symposiums : Paper published in a book
Engineering, computing & technology : Civil engineering
http://hdl.handle.net/2268/74649
3D simulation of Industrial Hall in case of fire. Benchmark between ABAQUS, ANSYS and SAFIR
English
Vassart, Olivier mailto [ArcelorMittal > > > >]
Cajot, Louis-Guy mailto [ArcelorMittal > > > >]
O'Connor, Marc [CORUS UK Ltd > > > >]
Shenkai, Y. [CORUS UK Ltd > > > >]
Fraud, C. [CTICM > > > >]
Zhao, Bin mailto [CTICM > > > >]
De la Quintana, Jesus mailto [Labein > > > >]
Martinez de Aragon, J. [Labein > > > >]
Franssen, Jean-Marc mailto [Université de Liège - ULg > Département Argenco : Secteur SE > Ingénierie du feu >]
Gens, Frederic mailto [Université de Liège - ULg > > > >]
Jul-2004
Interflam2004 Proceedings. Fire Sciences and Engineering Conference
Interscience
1315-1324
Yes
No
International
0 9541216 3 5
London
UK
10th International Fire Science & Engineering Conference
5-7 July 2004
Edinburgh
U.K.
[en] Fire ; Structure ; Benchmark ; Numerical modelling ; SAFIR
[en] For simple storey buildings, the structural behaviour in case of fire is relevant only for the safety of the firemen. The protection of occupants and goods is a matter of fire spread, smoke propagation, active fire fighting measures and evacuation facilities. Brittle failure, progressive collapse and partial failure of façades elements outwards may endanger the fire fighters and have to be avoided. In order to deal with such an objective, the simulation softwares has to cover the 3D structural behaviour including membrane and restrained effects as well as the failure mode so that post-local failure stage can be analysed. Such calculation models (ANSYS, ABAQUS and SAFIR [1]) have been compared true a benchmark. In this benchmark, two different users used ABAQUS.
Researchers
http://hdl.handle.net/2268/74649

File(s) associated to this reference

Fulltext file(s):

FileCommentaryVersionSizeAccess
Open access
2004 3D Simulation of industrial hall in case of fire Benchmark.pdfAuthor preprint220.24 kBView/Open

Bookmark and Share SFX Query

All documents in ORBi are protected by a user license.