External report (Reports)
Utilisation du bois dans la construction - Essai de résistance au feu sur un escalier en bois
Franssen, Jean-Marc; Lansival, Jean-Baptiste; Wellens, Eric et al.
2009
 

Files


Full Text
09 10 07 Rapport Escalier.doc
Author postprint (4.19 MB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
Fire; Wood; Timber; Test; Staircase
Abstract :
[en] A fire resistance test has been performed on a short staircase made of wood. It was made of 6 steps, 3 made of oak and 3 made of beech, all with different thicknesses. All 6 steps were loaded by mass. The pyrolysis rate as well as the time of collapse was observed for each step.
Disciplines :
Civil engineering
Author, co-author :
Franssen, Jean-Marc  ;  Université de Liège - ULiège > Département Argenco : Secteur SE > Ingénierie du feu
Lansival, Jean-Baptiste
Wellens, Eric ;  Université de Liège - ULiège > Département Argenco : Secteur SE > Struct. en béton, struc. en bois et résist. au feu
Dumont, Fabien ;  Université de Liège - ULiège > Département Argenco : Secteur SE > Ingénierie du feu
Language :
French
Title :
Utilisation du bois dans la construction - Essai de résistance au feu sur un escalier en bois
Alternative titles :
[en] Utilisation of wood in building construction - Fire test on a timber staircase
Publication date :
07 October 2009
Publisher :
ULg, Liege, Belgium
Number of pages :
15
Commissioned by :
Institut de Sécurité Incendie - Instituut voor Brandveiligheid (ISIB)
Name of the research project :
Recherche scientifique 2009
Funders :
Minsitry of Interior, Belgium
Available on ORBi :
since 20 August 2010

Statistics


Number of views
105 (12 by ULiège)
Number of downloads
3 (2 by ULiège)