Reference : Preliminary Research Study on the Fire Resistance of Stainless Steel-Reinforced Concrete...
Reports : External report
Engineering, computing & technology : Civil engineering
http://hdl.handle.net/2268/63074
Preliminary Research Study on the Fire Resistance of Stainless Steel-Reinforced Concrete members
English
Gernay, Thomas mailto [Université de Liège - ULg > Département Argenco : Secteur SE > Ingénierie du feu >]
alonso, Alain mailto [Université de Liège - ULG > ArGEnCo > Feu, bois, béton > >]
Franssen, Jean-Marc mailto [Université de Liège - ULg > Département Argenco : Secteur SE > Ingénierie du feu >]
22-Jun-2010
ULg
55
Liege
Belgium
[en] Fire resistance ; Stainless steel
[en] In this project, it is examined whether and under which conditions the good resistance to high temperature of stainless steel bars can lead to better fire resistance when used in reinforced concrete columns, beams and slabs working in tensile membrane action.
International Stainless Steel Forum
Researchers ; Professionals
http://hdl.handle.net/2268/63074

File(s) associated to this reference

Fulltext file(s):

FileCommentaryVersionSizeAccess
Restricted access
Preliminary Research Study on the Fire Resistance of SS Reinforced Concrete members.docAuthor postprint4.86 MBRequest copy

Bookmark and Share SFX Query

All documents in ORBi are protected by a user license.