Reference : Development and evaluation of an automated atlas-based image analysis method for micr...
Scientific journals : Article
Human health sciences : Radiology, nuclear medicine & imaging
http://hdl.handle.net/2268/5070
Development and evaluation of an automated atlas-based image analysis method for microPET studies of the rat brain.
English
Rubins, Daniel J. [> > > >]
Melega, William P. [> > > >]
Lacan, Goran [> > > >]
Way, Baldwin [> > > >]
Plenevaux, Alain mailto [Université de Liège - ULg > > Centre de recherches du cyclotron >]
Luxen, André mailto [Université de Liège - ULg > Département de chimie (sciences) > Chimie organique de synthèse - Centre de recherches du cyclotron >]
Cherry, Simon R. [> > > >]
2003
NeuroImage
Academic Press
20
4
2100-18
Yes (verified by ORBi)
International
1053-8119
1095-9572
Orlando
FL
[en] Animals ; Atlases as Topic ; Automation ; Brain/anatomy & histology/radionuclide imaging ; Brain Mapping/methods ; Cerebellum/physiology/radionuclide imaging ; Cerebral Cortex/physiology/radionuclide imaging ; Dopamine/physiology ; Hippocampus/physiology/radionuclide imaging ; Image Interpretation, Computer-Assisted/methods ; Image Processing, Computer-Assisted ; Magnetic Resonance Imaging ; Neostriatum/physiology/radionuclide imaging ; Rats ; Rats, Sprague-Dawley ; Serotonin/physiology ; Thalamus/physiology/radionuclide imaging ; Tomography, Emission-Computed/standards ; Tomography, Emission-Computed, Single-Photon
[en] An automated method for placement of 3D rat brain atlas-derived volumes of interest (VOIs) onto PET studies has been designed and evaluated. VOIs representing major structures of the rat brain were defined on a set of digitized cryosectioned images of the rat brain. For VOI placement, each PET study was registered with a synthetic PET target constructed from the VOI template. Registration was accomplished with an automated algorithm that maximized the mutual information content of the image volumes. The accuracy and precision of this method for VOI placement was determined using datasets from PET studies of the striatal dopamine and hippocampal serotonin systems. Each evaluated PET study could be registered to at least one synthetic PET target without obvious failure. Registration was critically dependent upon the initial position of the PET study relative to the synthetic PET target, but not dependent on the amount of synthetic PET target smoothing. An evaluation algorithm showed that resultant radioactivity concentration measurements of selected brain structures had errors=2% due to misalignment with the corresponding VOI. Further, radioligand binding values calculated from these measurements were found to be more precise than those calculated from measurements obtained with manually drawn regions of interest (ROIs). Overall, evaluation results demonstrated that this atlas-derived VOI method can be used to obtain unbiased measurements of radioactivity concentration from PET studies. Its automated features, and applicability to different radioligands and brain regions, will facilitate quantitative rat brain PET assessment procedures.
Centre de Recherches du Cyclotron - CRC ; Molecular and medical pharmacology UCLA
Fonds de la Recherche Scientifique (Communauté française de Belgique) - F.R.S.-FNRS ; University California Los Angeles UCLA
Researchers ; Professionals ; Students
http://hdl.handle.net/2268/5070

File(s) associated to this reference

Fulltext file(s):

FileCommentaryVersionSizeAccess
Restricted access
Neuroimage 2003.pdfNo commentaryPublisher postprint1.38 MBRequest copy

Bookmark and Share SFX Query

All documents in ORBi are protected by a user license.