Article (Scientific journals)
Enantioselective Determination of Oxprenolol in Human Plasma Using Dialysis Coupled on-Line to Reversed-Phase Chiral Liquid Chromatography
Ceccato, Attilio; Toussaint, B.; Chiap, Patrice et al.
1997In Journal of Pharmaceutical and Biomedical Analysis, 15 (9-10), p. 1365-74
Peer Reviewed verified by ORBi
 

Files


Full Text
articleACeccatoJPBAoxprenolol_1997.pdf
Publisher postprint (645.37 kB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Abstract :
[en] A fully automated method for the determination of the enantiomers of oxprenolol in human plasma was developed, involving dialysis through a cellulose acetate membrane, clean-up and enrichment of the dialysate on a short precolumn and subsequent chiral liquid chromatographic (LC) analysis. All sample handling operations were executed automatically by a sample processor equipped with a robotic arm (ASTED system). The trace enrichment column (TEC) was packed with octadecylsilica. After conditioning of the TEC with the LC mobile phase and pH 3.0 acetate buffer. After the enrichment step, the analyte was transferred by the LC mobile phase to the analytical column by means of a switching valve. The influence of different parameters of the dialysis process on the recovery of oxprenolol was first investigated using achiral LC conditions. The volume as well as the aspirating and dispensing flow rates of the acceptor solution were the main parameters studied. Oxprenolol was separated on a C18 stationary phase used for the enantioseparation of oxprenolol was a Chiralcel OD-R column which contained cellulose tris (3,5-dimethylphenylcarbamate) coated on silica as chiral selector. The corresponding mobile phase consisted of a mixture of pH 6.0 phosphate buffer containing NaClO4 at 0.45 M concentration and acetonitrile (70:30 v/v). UV detection was performed at 273 nm. The method developed was validated. Recoveries for each enantiomer of oxprenolol were about 80%. The method was found to be linear in the 50-2500 ng ml-1 concentration range (r2 = 0.999 for both enantiomers) and good results with respect to intra- and inter-day reproducibility as well as accuracy were obtained.
Disciplines :
Pharmacy, pharmacology & toxicology
Author, co-author :
Ceccato, Attilio ;  Université de Liège - ULiège > Département de pharmacie > Analyse des médicaments
Toussaint, B.
Chiap, Patrice ;  Université de Liège - ULiège > Département de pharmacie > Analyse des médicaments
Hubert, Philippe  ;  Université de Liège - ULiège > Chimie analytique
Crommen, Jacques ;  Université de Liège - ULiège > Département de pharmacie > Analyse des médicaments
Language :
English
Title :
Enantioselective Determination of Oxprenolol in Human Plasma Using Dialysis Coupled on-Line to Reversed-Phase Chiral Liquid Chromatography
Publication date :
June 1997
Journal title :
Journal of Pharmaceutical and Biomedical Analysis
ISSN :
0731-7085
eISSN :
1873-264X
Publisher :
Elsevier, Amsterdam, Netherlands
Volume :
15
Issue :
9-10
Pages :
1365-74
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 15 January 2010

Statistics


Number of views
49 (3 by ULiège)
Number of downloads
0 (0 by ULiège)

Scopus citations®
 
24
Scopus citations®
without self-citations
13
OpenCitations
 
18

Bibliography


Similar publications



Contact ORBi