[en] A morphometric study of the proximal radius was performed with computed tomography scanning in 51 healthy adults. These dimensions were then compared with those of a commercially available floating radial head prosthesis. Results were expressed as mean values, SD, and minimum and maximum values. The minimum and maximum diameters of the radial head were 21.9 +/- 1.9 mm and 22.9 +/- 1.9 mm, respectively. The minimum and maximum intramedullary diameters of the radial neck were 8.3 +/- 1.3 mm and 9.3 +/- 1.5 mm, respectively. The combined length of the radial head and neck was 22.47 +/- 2.84 mm. The implications for prosthetic design are as follows: the small floating cup (19 mm in diameter) is too small for the large majority of adults, the large floating cup (22 mm in diameter) is closer to the radial anatomy, the mean values are significantly different between male and female patients, and a single component would suffice for right and left elbows.
Disciplines :
Surgery Orthopedics, rehabilitation & sports medicine
Author, co-author :
Popovic, Nebojsa
Djekic, Julien
Lemaire, Roger ; Université de Liège - ULiège > Services généraux (Faculté de médecine) > Relations académiques et scientifiques (Médecine)
Gillet, Philippe ; Université de Liège - ULiège > Département des sciences cliniques > Chirurgie de l'appareil locomoteur
Language :
English
Title :
A comparative study between proximal radial morphology and the floating radial head prosthesis.
P.D. Beredjiklian, V. Nalbantoglu, H.G. Potter, R.N. Hotchkiss Prosthetic radial components and proximal radial head morphology a mismatch J Shoulder Elbow Surg 8 1999 471 475
G. Captier, F. Canovas, N. Mercier, E. Thomas, F. Bonnel Biometry of the radial head biomechanical implications in pronation and supination Surg Radiol Anat 24 2002 295 301
C.R. Carr, J.W. Howard Metallic cap replacement of the radial head following fracture West J Surg Obstet Gynecol 59 1951 539 546
J.C. Cherry Use of acrylic prosthesis in the treatment of fracture of the head of the radius J Bone Joint Surg Br 35 1953 70 71
G.G. Gupta, G. Lucas, D.L. Hahn Biomechanical and computer analysis of the radial head prostheses J Shoulder Elbow Surg 6 1997 37 48
G.G. Gupta, P.H. Moore-Jansen, G.L. Lucas Differences in radial head dimensions based on gender, race, age and side Orthop Trans 16 1992 342
I.J. Harrington, A. Sekyi-Otu, T.W. Barrington, D.C. Evans, V. Tuli The functional outcome with metallic radial head implants in the treatment of unstable elbow fractures a long-term review J Trauma 50 2001 46 53
I.J. Harrington, A.A. Tountas Replacement of the radial head in the treatment of unstable elbow fractures Injury 12 1981 405 412
F. Holmenschlager, J.P. Halm, S. Piatek, S. Schubert, S. Winckler Comminuted radial head fractures. Initial experiences with a Judet radial head prosthesis [in German] Unfallchirurg 105 2002 344 352
T. Judet, C. Garreau-Deloubresse, P. Pirion, G. Charnley A floating prosthesis for radial head fractures J Bone Joint Surg Br 78 1996 244 249
G.J.W. King, Z.D.S. Zarzour, S.D. Pattersen, J.A. Johnson An anthropometric study of the radial head. Implication in the design of a prosthesis J Arthroplasty 16 2001 112 117
G.J.W. King, Z.D.S. Zarzour, C.D. Dunning, S.D. Patterson, J.A. Johnson Metallic radial head arthroplasty improves the valgus stability of the medial collateral deficient elbow Clin Orthop 368 1999 114 125
D.J. Knight, L.A. Rymaszewski, A.A. Amis, J.H. Miller Primary replacement of a fractured radial head J Bone Joint Surg Br 75 1993 572 576
J. Leppilathi, P. Jalovaara Early excision of the radial head for fracture Int Orthop 24 2001 160 162
A. Mikic, S. Vukadinovic Late results in fractures of the radial head treated by excision Clin Orthop 181 1983 220 228
J. Moro, J. Werier, J.C. MacDermid, S.D. Patterson, G.J. King Arthroplasty with a metal radial head for unreconstructible fractures of the radial head J Bone Joint Surg Am 83 2001 1201 1211
B.F. Morrey Complex instability of the elbow J Bone Joint Surg Am 79 1997 460 469
B.F. Morrey, K.N. An, T.J. Stormont Force transmission through the radial head J Bone Joint Surg Am 70 1988 250 256
S. Pomianowski, G. Sawicki, J. Orlowski Bipolar radial head prosthesis-own design [in Polish] Chir Narzadow Ruchu Ortop Pol 68 2003 53 57
N. Popovic, P. Gillet, A. Rodriguez, R. Lemaire Fracture of the radial head with associated elbow dislocation results of treatment using a floating radial head prosthesis J Orthop Trauma 14 2000 171 177
S. Smets, K. Govaers, N. Jansen The floating radial head prosthesis for comminuted radial head fractures a multicentric study Acta Orthop Belg 66 2000 353 358
K. Speed Ferrule caps for the head of the radius Surg Gynecol Obstet 73 1941 845 850
A.B. Swanson, S.H. Jaeger, D. La Rochelle Comminuted fractures of the radial head. The role of silicone implant replacement arthroplasty J Bone Joint Surg Am 63 1981 1039 1049
F. Van Glabbeek, R. Van Riet, J. Verstreken Current concepts in the treatment of radial head fractures in the adult. A clinical and biomechanical approach Acta Orthop Belg 67 2001 340 341