Reference : Automated determination of pirlindole enantiomers in plasma by on-line coupling of a pre...
Scientific journals : Article
Human health sciences : Pharmacy, pharmacology & toxicology
Physical, chemical, mathematical & earth Sciences : Chemistry
http://hdl.handle.net/2268/4190
Automated determination of pirlindole enantiomers in plasma by on-line coupling of a pre-column packed with restricted access material to a chiral liquid chromatographic column
English
Chiap, Patrice mailto [Université de Liège - ULg > Département de pharmacie > Analyse des médicaments >]
Ceccato, Attilio mailto [Université de Liège - ULg > Département de pharmacie > Analyse des médicaments >]
Gora, R. [> > > >]
Hubert, Philippe mailto [Université de Liège - ULg > > Chimie analytique >]
Geczy, J. [> > > >]
Crommen, Jacques mailto [Université de Liège - ULg > Département de pharmacie > Analyse des médicaments >]
15-Jan-2002
Journal of Pharmaceutical & Biomedical Analysis
Pergamon-Elsevier Science Ltd
27
3-4
447-455
International
0731-7085
Oxford
[en] pirlindole enantiomers ; chiral liquid chromatography ; plasma ; sample preparation ; column-switching ; restricted access material
[en] A fully automated liquid chromatographic method has been developed for the determination of the enantiomers of pirlindole, an antidepressant drug, in human plasma. The method is based on the use of a pre-column packed with restricted access material (RAM) (LiChrospher ADS RP-4) for sample clean-up coupled to a column containing a cellulose tris-(3,5-dimethylphenylcarbamate) based chiral stationary phase (Chiralcel OD-R) for the separation and quantitative analysis of pirlindole enantiomers. A 50-microl plasma volume was injected directly onto the pre-column using a mixture of phosphate buffer (pH 5.0) and methanol (97:3; v/v) as washing liquid. By rotation of a switching valve, the analytes were then eluted in the back-flush mode with the LC mobile phase. A complete separation of pirlindole enantiomers was obtained in 22 min on the Chiralcel OD-R column, using a mobile phase made of a mixture of phosphate buffer (pH 5.0) containing 50 mM sodium perchlorate and acetonitrile (65:35; v/v). The flow-rate was 0.6 ml/min and the analytes were detected fluorometrically using 295 and 340 nm as excitation and emission wavelengths, respectively. The method was then validated and was found to be linear in the 2.5-200 ng/ml range. The limit of detection was lower than 1 ng/ml. Repeatability and intermediate precision at a concentration of 50 ng/ml were about 1.5 and 3.5%, respectively.
http://hdl.handle.net/2268/4190

File(s) associated to this reference

Fulltext file(s):

FileCommentaryVersionSizeAccess
Restricted access
articlePChiapJPBApirlindole_2002.pdfPublisher postprint169.27 kBRequest copy

Bookmark and Share SFX Query

All documents in ORBi are protected by a user license.