Article (Scientific journals)
Internal energy build-up in matrix-assisted laser desorption/ionization
Gabelica, Valérie; Schulz, Eric; Karas, Michael
2004In Journal of Mass Spectrometry, 39 (6), p. 579-593
Peer Reviewed verified by ORBi
 

Files


Full Text
2004-JMS-39-579_Internal Energy in MALDI.pdf
Publisher postprint (336.82 kB)
Request a copy
Full Text Parts
2004 JMS MALDI internal energy.pdf
Author preprint (319.48 kB)
This is a preprint of an article published in J. Mass Spectrom. © 2004 John Wiley & Sons Ltd.
Download

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
internal energy; metastable ions; matrix-assisted laser desorption/ionization; atmospheric pressure; matrix effects; RRKM; delayed extraction; mass spectrometry
Abstract :
[en] This paper reports detailed studies on the internal energy of ions formed in matrix-assisted laser desorption/ionization (MALDI) using delayed extraction MALDI-time-of-flight (TOF) and atmospheric pressure (AP) MALDI mass spectrometric (MS) methods. We use benzylpyridinium cations as internal energy probes. Our study reveals three distinct contributions to internal energy build-up in vacuum-MALDI (classical MALDI-TOF), each having different effects on ion fragmentation. Some fragments are formed before ion extraction (i.e. no more than 100 ns after the laser impact), and they are therefore well resolved and recorded as sharp signals in the MALDI-TOFMS scan. This prompt fragmentation can have two origins: (i) in-plume thermal activation, presumably always present, and (ii) in-plume chemical activation, in the course of reactions with hydrogen radicals. In addition to early internal energy build-up associated with these well-resolved promptly formed fragments, a broad peak slightly offset to higher masses could be detected corresponding to fragments formed after the extraction has started. This second signal corresponds to a third source of internal energy in MALDI ions, (iii) the extraction-induced collisional activation of the ions with the neutral components of the plume. These three contributions are difficult to quantify in vacuum-MALDI, because of the combined influence of several parameters (nature of the matrix, spot-to-spot variability, total laser exposure, delay time, acceleration voltage) on extraction-induced fragmentation. AP-MALDI, on the other hand, has two advantages for comparative studies of analyte fragmentation. First, extraction-induced fragmentation is absent, and only the contributions of early plume activation remain. Second, the reproducibility is far better than in vacuum-MALDI. AP-MALDI is therefore expected to shed new light on the early steps of the MALDI process. Copyright (C) 2004 John Wiley Sons, Ltd.
Disciplines :
Chemistry
Biochemistry, biophysics & molecular biology
Author, co-author :
Gabelica, Valérie ;  Institut für Pharmazeutische Chemie, Johann-Wolfgang Goethe Universität Frankfurt, Biozentrum, Marie-Curie Strasse 9-11, D-60439 Frankfurt am Main, Germany
Schulz, Eric;  Institut für Pharmazeutische Chemie, Johann-Wolfgang Goethe Universität Frankfurt, Biozentrum, Marie-Curie Strasse 9-11, D-60439 Frankfurt am Main, Germany
Karas, Michael;  Institut für Pharmazeutische Chemie, Johann-Wolfgang Goethe Universität Frankfurt, Biozentrum, Marie-Curie Strasse 9-11, D-60439 Frankfurt am Main, Germany
Language :
English
Title :
Internal energy build-up in matrix-assisted laser desorption/ionization
Publication date :
2004
Journal title :
Journal of Mass Spectrometry
ISSN :
1076-5174
eISSN :
1096-9888
Publisher :
John Wiley & Sons, Inc, Chichester, United Kingdom
Volume :
39
Issue :
6
Pages :
579-593
Peer reviewed :
Peer Reviewed verified by ORBi
Funders :
F.R.S.-FNRS - Fonds de la Recherche Scientifique [BE]
AvH - Alexander von Humboldt-Stiftung [DE]
Commentary :
This is a preprint version of an article published in J. Mass Spectrom. (2004), 39, 579-593, © 2004 John Wiley & Sons Ltd.
Available on ORBi :
since 24 July 2008

Statistics


Number of views
140 (4 by ULiège)
Number of downloads
281 (4 by ULiège)

Scopus citations®
 
111
Scopus citations®
without self-citations
99
OpenCitations
 
107

Bibliography


Similar publications



Contact ORBi