[en] In this work we have developed and validated an accurate and fast methodology for the determination of 4-nonylphenol (technical mixture) in complex matrix water samples by UHPLC-ESI-MS/MS. The procedure is based on isotope dilution mass spectrometry (IDMS) in combination with isotope pattern deconvolution (IPD), which provides the concentration of the analyte directly from the spiked sample without requiring any methodological calibration graph. To avoid any possible isotopic effect during the analytical procedure the in-house synthesized (13)C1-4-(3,6-dimethyl-3-heptyl)phenol was used as labeled compound. This proposed surrogate was able to compensate the matrix effect even from wastewater samples. A SPE pre-concentration step together with exhaustive efforts to avoid contamination were included to reach the signal-to-noise ratio necessary to detect the endogenous concentrations present in environmental samples. Calculations were performed acquiring only three transitions, achieving limits of detection lower than 100ng/g for all water matrix assayed. Recoveries within 83-108% and coefficients of variation ranging from 1.5% to 9% were obtained. On the contrary a considerable overestimation was obtained with the most usual classical calibration procedure using 4-n-nonylphenol as internal standard, demonstrating the suitability of the minimal labeling approach.
Soares, A., Guieysse, B., Jefferson, B., Cartmell, E., Lester, J.N., (2008) Environ. Int., 34, p. 1033
(2000) Establishment and Framework for Community Action in the Field of Water Policy, , Directive 2000/60/EC, European Parliament and the Council of the European Union
(2008) Environmental Quality Standards in the Field of Water Policy, Amending and Subsequently Repealing Council Directives 82/176/EEC, 83/513/EEC, 84/156/EEC, 84/491/EEC, 86/280/EEC and Amending Directive 2000/60/EC, , Directive 2008/105/EC, European Parliament and the Council of the European Union
(2012) Proposal for a Directive of the European parliament and of the council amending Directives 2000/60/EC and 2008/105/EC as regards priority substances in the field of water policy (COM(2011)876)
Rabouan, S., Dupuis, A., Cariot, A., Albouy-Llaty, M., Migeot, V., Legube, B., (2012) Trends Anal. Chem., 37, p. 112
Stottmeister, E., Heemken, O.P., Hendel, P., Donnevert, G., Frey, S., Allmendinger, H., Sawal, G., Spilker, R., (2009) Anal. Chem., 81, p. 6765
Loos, R., Gawlik, B.M., Locoro, G., Rimaviciute, E., Contini, S., Bidoglio, G., (2009) Environ. Pollut., 157, p. 561
Olkowska, E., Polkowska, Z., Namieśnik, J., (2012) Talanta, 88, p. 1
Gallart-Ayala, E., Moyano, E., Galceran, M.T., (2010) Mass. Spectrom. Rev., p. 776
Fischer, A.R., Lan, N.T.P., Wiedemann, C., Heide, P., Werner, P., Schmidt, A.W., Theumer, G., Knölker, H.-J., (2010) J. Chromatogr. A, 1217, p. 2950
Loos, R., Locoro, G., Contini, S., (2010) Water Res., 44, p. 2325
Salgueiro-González, N., Concha-Graña, E., Turnes-Carou, I., Muniategui-Lorenzo, S., López-Mahía, P., Prada-Rodríguez, D., (2012) J. Chromatogr. A, 1223, p. 1
Loos, R., Hanke, G., Umlauf, G., Eisenreich, S.J., (2007) Chemosphere, 66, p. 690
González-Antuña, A., Rodríguez-González, P., Centineo, G., García Alonso, J.I., (2010) Analyst, 135, p. 953
González-Antuña, A., Rodríguez-González, P., Lavandera, I., Centineo, G., Gotor, V., García Alonso, J.I., (2012) Anal. Bioanal. Chem., 402, p. 1879
Rodríguez-González, P., García Alonso, J.I., (2010) J. Anal. Atom. Spectrom., 25, p. 239
Ramaley, L., Cubero Herrera, L., (2008) Rapid Commun. Mass Spectrom., p. 2707
Meija, J., Caruso, J., (2004) J. Am. Soc. Mass Spectrom., 15, p. 654
Vega-Morales, T., Sosa-Ferrera, Z., Santana-Rodríguez, J.J., (2010) J. Hazard. Mater., 183, p. 701
Fontanals, N., Marcé, R.M., Borrull, F., (2007) J. Chromatogr. A, 1152, p. 14
(2012) Method validation and quality control procedures for pesticide residues analysis in food and feed, Document No. SANCO/12495/2011, Brussels, December 2011, , http://ec.europa.eu/food/plant/protection/pesticides/docs/qualcont, European Commission, DG-SANCO
(2002) Off. J. Eur. Commun., L221, p. 8. , European Union Decision 2002/657/EC, August
Petrovic, M., Diaz, A., Ventura, F., Barceló, D., (2001) Anal. Chem., 73, p. 5886