[en] OBJECTIVES: Polymer-infiltrated-ceramic-network (PICN) materials constitute an innovative class of CAD-CAM materials offering promising perspectives in prosthodontics, but no data are available in the literature regarding their biological properties. The objective of the present study was to evaluate the in vitro biocompatibility of PICNs with human gingival fibroblasts (HGFs) in comparison with materials typically used for implant prostheses and abutments. METHODS: HGF attachment, proliferation and spreading on discs made of PICN, grade V titanium (Ti), yttrium zirconia (Zi), lithium disilicate glass-ceramic (eM) and polytetrafluoroethylene (negative control), were evaluated using a specific insert-based culture system (IBS-R). Sample surface properties were characterized by XPS, contact angle measurement, profilometry and SEM. RESULTS: Ti and Zi gave the best results regarding HGF viability, morphology, number and coverage increase with time in comparison with the negative control, while PICN and eM gave intermediate results, cell spreading being comparable for PICN, Ti, Zi and eM. Despite the presence of polymers and their related hydrophobicity, PICN exhibited comparable results to glass-ceramic materials, which could be explained by the mode of polymerization of the monomers. SIGNIFICANCE: The results of the present study confirm that the currently employed materials, i.e. Ti and Zi, can be considered to be the gold standard of materials in terms of HGF behavior, while PICN gave intermediate results comparable to eM. The impact of the present in vitro results needs to be further investigated clinically, particularly in the view of the utilization of PICNs for prostheses on bone-level implants.
Research center :
d‐BRU - Dental Biomaterials Research Unit - ULiège [BE]
[1] Rompen, E., The impact of the type and configuration of abutments and their (repeated) removal on the attachment level and marginal bone. Eur J Oral Implantol 5:Suppl. (2012), S83–S90.
[2] Abrahamsson, I., Berglundh, T., Glantz, P.O., Lindhe, J., The mucosal attachment at different abutments. An experimental study in dogs. J Clin Periodontol 25 (1998), 721–727.
[3] Abrahamsson, I., Berglundh, T., Lindhe, J., The mucosal barrier following abutment dis/reconnection. An experimental study in dogs. J Clin Periodontol 24 (1997), 568–572.
[4] Mainjot, A.K., Dupont, N.M., Oudkerk, J.C., Dewael, T.Y., Sadoun, M.J., From artisanal to CAD-CAM blocks: state of the art of indirect composites. J Dent Res 95 (2016), 487–495.
[5] Nguyen, J-F., Migonney, V., Ruse, N.D., Sadoun, M., Resin composite blocks via high-pressure high-temperature polymerization. Dental Mater 28 (2012), 529–534.
[6] Nguyen, J.F., Ruse, D., Phan, A.C., Sadoun, M.J., High-temperature-pressure polymerized resin-infiltrated ceramic networks. J Dent Res 93 (2014), 62–67.
[7] Phan, A.C., Tang M-l Nguyen, J-F., Ruse, N.D., Sadoun, M., High-temperature high-pressure polymerized urethane dimethacrylate—mechanical properties and monomer release. Dental Mater 30 (2014), 350–356.
[8] Kim, Y.S., Shin, S.Y., Moon, S.K., Yang, S.M., Surface properties correlated with the human gingival fibroblasts attachment on various materials for implant abutments: a multiple regression analysis. Acta Odontol Scand 73 (2015), 38–47.
[9] Moon, Y.H., Yoon, M.K., Moon, J.S., Kang, J.H., Kim, S.H., Yang, H.S., et al. Focal adhesion linker proteins expression of fibroblast related to adhesion in response to different transmucosal abutment surfaces. J Adv Prosthodont 5 (2013), 341–350.
[10] Pae, A., Lee, H., Kim, H.S., Kwon, Y.D., Woo, Y.H., Attachment and growth behaviour of human gingival fibroblasts on titanium and zirconia ceramic surfaces. Biomed Mater, 4, 2009, 025005.
[11] Takamori, E.R., Cruz, R., Goncalvez, F., Zanetti, R.V., Zanetti, A., Granjeiro, J.M., Effect of roughness of zirconia and titanium on fibroblast adhesion. Artif Organs 32 (2008), 305–309.
[12] Payer, M., Lorenzoni, M., Jakse, N., Kirmeier, R., Dohr, G., Stopper, M., et al. Cell growth on different zirconia and titanium surface textures: a morphologic in vitro study. J Dent Implant 4 (2010), 338–351.
[13] Rutkunas, V., Bukelskiene, V., Sabaliauskas, V., Balciunas, E., Malinauskas, M., Baltriukiene, D., Assessment of human gingival fibroblast interaction with dental implant abutment materials. J Mater Sci Mater Med, 26, 2015, 5481.
[14] Nothdurft, F.P., Fontana, D., Ruppenthal, S., May, A., Aktas, C., Mehraein, Y., et al. Differential behavior of fibroblasts and epithelial cells on structured implant abutment materials: a comparison of materials and surface topographies. Clin Implant Dentistry Related Res 17 (2015), 1237–1249.
[15] Yamano, S., Ma, A.K., Shanti, R.M., Kim, S.W., Wada, K., Sukotjo, C., The influence of different implant materials on human gingival fibroblast morphology, proliferation, and gene expression. Int J Oral Maxillofac Implants 26 (2011), 1247–1255.
[16] Linkevicius, T., Vaitelis, J., The effect of zirconia or titanium as abutment material on soft peri-implant tissues: a systematic review and meta-analysis. Clin Oral Implants Res 26 (2015), 139–147.
[17] Brackett, M.G., Lockwood, P.E., Messer, R.L., Lewis, J.B., Bouillaguet, S., Wataha, J.C., In vitro cytotoxic response to lithium disilicate dental ceramics. Dent Mater 24 (2008), 450–456.
[18] Pabst, A.M., Walter, C., Grassmann, L., Weyhrauch, M., Brullmann, D.D., Ziebart, T., et al. Influence of CAD/CAM all-ceramic materials on cell viability, migration ability and adenylate kinase release of human gingival fibroblasts and oral keratinocytes. Clin Oral Investig 18 (2014), 1111–1118.
[19] Tete, S., Zizzari, V.L., Borelli, B., Zara, S., Sorrentino, R., et al. Proliferation and adhesion capability of human gingival fibroblasts onto zirconia, lithium disilicate and feldspathic veneering ceramic in vitro. Dent Mater J 33 (2014), 7–15.
[20] Messer, R.L., Lockwood, P.E., Wataha, J.C., Lewis, J.B., Norris, S., Bouillaguet, S., In vitro cytotoxicity of traditional versus contemporary dental ceramics. J Prosthet Dent 90 (2003), 452–458.
[21] Grenade, C., Moniotte, N., Rompen, E., Vanheusden, A., Mainjot, A., De Pauw-Gillet, M.-C., A new method using insert-based systems (IBS) to improve cell behavior study on flexible and rigid biomaterials. Cytotechnology, 2016, 10.1007/s10616-016-9964-3.
[22] Yang, Y., Zhou, J., Liu, X., Zheng, M., Yang, J., Tan, J., Ultraviolet light-treated zirconia with different roughness affects function of human gingival fibroblasts in vitro: the potential surface modification developed from implant to abutment. J Biomed Mater Res B Appl Biomater 103 (2015), 116–124.
[23] Raffaelli, L., Rossi Iommetti, P., Piccioni, E., Toesca, A., Serini, S., Resci, F., et al. Growth, viability, adhesion potential, and fibronectin expression in fibroblasts cultured on zirconia or feldspatic ceramics in vitro. J Biomed Mater Res A 86 (2008), 959–968.
[24] Kwon, Y.D., Choi, H.J., Lee, H., Lee, J.W., Weber, H.P., Pae, A., Cellular viability and genetic expression of human gingival fibroblasts to zirconia with enamel matrix derivative (Emdogain(R)). J Adv Prosthodont 6 (2014), 406–414.
[25] Zheng, M., Yang, Y., Liu, X.Q., Liu, M.Y., Zhang, X.F., Wang, X., et al. Enhanced biological behavior of in vitro human gingival fibroblasts on cold plasma-treated zirconia. PLoS One, 10, 2015, e0140278.
[26] Neunzehn, J., Luttenberg, B., Wiesmann, H.P., Investigation of biomaterials by human epithelial gingiva cells: an in vitro study. Head Face Med, 8, 2012, 35.
[27] Di Carmine, M., Toto, P., Feliciani, C., Scarano, A., Tulli, A., Strocchi, R., et al. Spreading of epithelial cells on machined and sandblasted titanium surfaces: an in vitro study. J Periodontol 74 (2003), 289–295.
[28] Zhang, Z., Wang, K., Bai, C., Li, X., Dang, X., Zhang, C., The influence of UV irradiation on the biological properties of MAO-formed ZrO2. Colloids Surf B, Biointerfaces 89 (2012), 40–47.
[29] Kim, Y.S., Ko, Y., Kye, S.B., Yang, S.M., Human Gingival Fibroblast (HGF-1) attachment and proliferation on several abutment materials with various colors. Int J Oral Maxillofac Implants 29 (2014), 969–975.
[30] Lin-Gibson, S., Sung, L., Forster, A.M., Hu, H., Cheng, Y., Lin, N.J., Effects of filler type and content on mechanical properties of photopolymerizable composites measured across two-dimensional combinatorial arrays. Acta Biomater 5 (2009), 2084–2094.
[31] Gupta, S.K., Saxena, P., Pant, V.A., Pant, A.B., Release and toxicity of dental resin composite. Toxicol Int 19 (2012), 225–234.
[32] Krifka, S., Spagnuolo, G., Schmalz, G., Schweikl, H., A review of adaptive mechanisms in cell responses towards oxidative stress caused by dental resin monomers. Biomaterials 34 (2013), 4555–4563.
[33] Gómez-Florit, M., Ramis, J.M., Xing, R., Taxt-Lamolle, S., Haugen, H.J., Lyngstadaas, S.P., et al. Differential response of human gingival fibroblasts to titanium- and titanium-zirconium-modified surfaces. J Periodont Res 49 (2014), 425–436.
[34] Mustafa, K., Silva Lopez, B., Hultenby, K., Wennerberg, A., Arvidson, K., Attachment and proliferation of human oral fibroblasts to titanium surfaces blasted with TiO2 particles. A scanning electron microscopic and histomorphometric analysis. Clin Oral Implants Res 9 (1998), 195–207.
[35] Albrektsson, T., Wennerberg, A., Oral implant surfaces: Part 1—review focusing on topographic and chemical properties of different surfaces and in vivo responses to them. Int J Prosthodont 17 (2004), 536–543.
[36] Gehrke, P., Tabellion, A., Fischer, C., Microscopical and chemical surface characterization of CAD/CAM zircona abutments after different cleaning procedures. A qualitative analysis. J Adv Prosthodont 7 (2015), 151–159.
[37] Happe, A., Röling, N., Schäfer, A., Rothamel, D., Effects of different polishing protocols on the surface roughness of Y-TZP surfaces used for custom-made implant abutments: a controlled morphologic SEM and profilometric pilot study. J Prosthetic Dentistry 113 (2015), 440–447.
[38] An, N., Rausch-fan, X., Wieland, M., Matejka, M., Andrukhov, O., Schedle, A., Initial attachment, subsequent cell proliferation/viability and gene expression of epithelial cells related to attachment and wound healing in response to different titanium surfaces. Dent Mater 28 (2012), 1207–1214.
[39] Noro, A., Kaneko, M., Murata, I., Yoshinari, M., Influence of surface topography and surface physicochemistry on wettability of zirconia (tetragonal zirconia polycrystal). J Biomed Mater Res Part B: Appl Biomater 101B (2013), 355–363.
[40] Vogler, E.A., Structure and reactivity of water at biomaterial surfaces. Adv Colloid Interface Sci 74 (1998), 69–117.
[41] Webb, K., Hlady, V., Tresco, P.A., Relative importance of surface wettability and charged functional groups on NIH 3T3 fibroblast attachment, spreading, and cytoskeletal organization. J Biomed Mater Res 41 (1998), 422–430.
[42] Zhang, F., Huang, Y., Li, X., Zhao, S., Surface modification and its effect on attachment, spreading, and proliferation of human gingival fibroblasts. Int J Oral Maxillofac Implants 26 (2011), 1183–1192.
[43] Guelcher, S.A., Hollinger, J.O., An introduction to biomaterials. 2005.
[44] Carré, A., Lacarrière, V., Cell adhesion to polystyrene substrates: relevance of interfacial free energy. Contact Angle Wettability Adhes, 2008.
[45] Kim, S.H., Ha, H.J., Ko, Y.K., Yoon, S.J., Rhee, J.M., Kim, M.S., et al. Correlation of proliferation, morphology and biological responses of fibroblasts on LDPE with different surface wettability. J Biomater Sci Polym Ed 18 (2007), 609–622.
[46] Lee, J.H., Khang, G., Lee, J.W., Lee, H.B., Interaction of different types of cells on polymer surfaces with wettability gradient. J Colloid Interface Sci 205 (1998), 323–330.
[47] Schulz, S., Tomakidi, P., Mauth, C., Kohal, R., Steinberg, T., Interactive fibroblast-keratinocyte co-cultures: an in vivo-like test platform for dental implant-based soft tissue integration. Tissue Eng Part C, Methods 18 (2012), 785–796.
[48] Watanabe, H., Saito, K., Kokubun, K., Sasaki, H., Yoshinari, M., Change in surface properties of zirconia and initial attachment of osteoblastlike cells with hydrophilic treatment. Dent Mater J 31 (2012), 806–814.
[49] Att, W., Hori, N., Takeuchi, M., Ouyang, J., Yang, Y., Anpo, M., et al. Time-dependent degradation of titanium osteoconductivity: an implication of biological aging of implant materials. Biomaterials 30 (2009), 5352–5363.