Paper published in a book (Scientific congresses and symposiums)
Evaluation of Adaptive Facades: The Case Study of AGC Headquarter in Belgium
Attia, Shady; Bashandy, Hamza
2016In Belis, Jan; Louter, Christian (Eds.) Challenging Glass 5
Peer reviewed
 

Files


Full Text
Attia_Final.pdf
Publisher postprint (664.03 kB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
glass building; design assist phase; commissioning; monitoring; operation and control; interview
Abstract :
[en] The evaluation of adaptive facades presents a challenge because there is no established evaluation strategy to systematically reach this goal and many of the available façade performance evaluation tools have limited applicability for such advanced building facades. This paper presents a case study for an adaptive glass façade and evaluates its performance. The evaluation focuses mainly on pre and post construction phase of adaptive facades: The design assist phase (including the durability test, visual mockup, onsite panel mounting and weather stripping), the commissioning phase (field verification and performance testing) and the monitoring phase. The selected project is a nearly zero energy building with unique façade comprising thermal isolated glass sunshades printed with white silk screen. These louvers respond dynamically and automatically to the angle of the sun which improves the control over energy consumption, solar radiation and glare with the ability to admit natural light into the building. The paper is part of the research activities of working group 3 of the European COST Action 1403 on “Adaptive Facades “. Different methods were used for evaluation, this include: interviews with the architect, façade engineer and technical control specialist, reviews of standard and codes and a systematic process mapping. A documentation of the case study describing the post construction occupant comfort and façade operation was prepared. This paper’s audience is mainly architects, building façade engineers together with facility managers concerned with the process of design, construction and operation of adaptive glass facades. The outcome of this study identifies effective strategies for the design and performance evaluation of optimal adaptive facades.
Research center :
SBD Lab
Disciplines :
Architecture
Author, co-author :
Attia, Shady  ;  Université de Liège > Département ArGEnCo > Techniques de construction des bâtiments
Bashandy, Hamza 
Language :
English
Title :
Evaluation of Adaptive Facades: The Case Study of AGC Headquarter in Belgium
Publication date :
17 June 2016
Event name :
Challenging Glass 5 – Conference on Architectural and Structural Applications of Glass
Event organizer :
Ghent University
Event place :
Ghent, Belgium
Event date :
16 June 2016
Audience :
International
Main work title :
Challenging Glass 5
Author, co-author :
Belis, Jan
Louter, Christian
Publisher :
Ghent University, Ghent, Belgium
Edition :
1
ISBN/EAN :
978-90-825-2680-6
Peer reviewed :
Peer reviewed
Available on ORBi :
since 16 June 2016

Statistics


Number of views
615 (32 by ULiège)
Number of downloads
1306 (34 by ULiège)

Bibliography


Similar publications



Contact ORBi