Article (Scientific journals)
Quality assurance for the EORTC 22071¿26071 study: dummy run prospective analysis.
Fairchild, Alysa; Langendijk, Johannes A; Nuyts, Sandra et al.
2014In Radiation Oncology, 9 (1), p. 248
Peer Reviewed verified by ORBi
 

Files


Full Text
Fairchild et al. - 2014 - Quality assurance for the EORTC 22071¿26071 study dummy run prospective analysis.pdf
Publisher postprint (896.59 kB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Abstract :
[en] PurposeThe phase III 22071¿26071 trial was designed to evaluate the addition of panitumumab to adjuvant chemotherapy plus intensity modulated radiotherapy (IMRT) in locally advanced resected squamous cell head and neck cancer. We report the results of the dummy run (DR) performed to detect deviations from protocol guidelines.Methods and MaterialsDR datasets consisting of target volumes, organs at risk (OAR) and treatment plans were digitally uploaded, then compared with reference contours and protocol guidelines by six central reviewers. Summary statistics and analyses of potential correlations between delineations and plan characteristics were performed.ResultsOf 23 datasets, 20 (87.0\%) GTVs were evaluated as acceptable/borderline, along with 13 (56.5\%) CTVs and 10 (43.5\%) PTVs. All PTV dose requirements were met by 73.9 of cases. Dose constraints were met for 65.2-100 of mandatory OARs. Statistically significant correlations were observed between the subjective acceptability of contours and the ability to meet dose constraints for all OARs (p¿¿¿0.01) except for the parotids and spinal cord. Ipsilateral parotid doses correlated significantly with CTV and PTV volumes (p¿¿¿0.05).ConclusionsThe observed wide variations in treatment planning, despite strict guidelines, confirms the complexity of development and quality assurance of IMRT-based multicentre studies for head and neck cancer.
Disciplines :
Oncology
Author, co-author :
Fairchild, Alysa
Langendijk, Johannes A
Nuyts, Sandra
Scrase, Christopher
Tomsej, Milan
Schuring, Danny
GULYBAN, Akos ;  Centre Hospitalier Universitaire de Liège - CHU > Service médical de radiothérapie
Ghosh, Sunita
Weber, Damien C.
Budach, Wilfried
Language :
English
Title :
Quality assurance for the EORTC 22071¿26071 study: dummy run prospective analysis.
Publication date :
2014
Journal title :
Radiation Oncology
eISSN :
1748-717X
Publisher :
BioMed Central, United Kingdom
Volume :
9
Issue :
1
Pages :
248
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 18 June 2015

Statistics


Number of views
62 (5 by ULiège)
Number of downloads
449 (0 by ULiège)

Scopus citations®
 
12
Scopus citations®
without self-citations
8
OpenCitations
 
11

Bibliography


Similar publications



Contact ORBi