Article (Scientific journals)
Concordance between muscle mass assessed by bioelectrical impedance analysis and by dual energy X-ray absorptionmetry among elderly people: a cross-sectional study
Buckinx, Fanny; Reginster, Jean-Yves; Dardenne, Nadia et al.
2015In BMC Musculoskeletal Disorders, 16 (1), p. 60-67
Peer Reviewed verified by ORBi
 

Files


Full Text
Concordance between muscle mass assessed by bioelectrical impedance analysis and by dual energy X-ray absorptiometry a cross-sectional study.pdf
Publisher postprint (418.86 kB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
BIA; Muscle mass; Appendicular lean mass; DXA
Abstract :
[en] BACKGROUND: Besides magnetic resonance imaging, dual energy X-ray absorptiometry (DXA) seems the most reliable tool to evaluate body composition and is often considered as the gold standard in clinical practice. Bioelectrical impedance analysis (BIA) could provide a simpler, portative, and less expensive alternative. Because the body composition assessment by BIA is device-dependent, the aim of this study was to appraise the concordance between the specific bioelectrical impedance device InBody S10 and DXA for the body composition evaluation. METHODS: Body composition, included appendicular lean mass divided by height squared (ALM/ht2) was measured by DXA (Hologic QDR Discovery device) and by BIA (InBody S10 Biospace device). Agreement between tools was assessed by means of the Bland Altman method and reliability was determined using the IntraClass Coefficient (ICC). ICC was also computed to assess the reliability of the test-retest performed by the same operator or by two different ones. RESULTS: A total of 219 subjects were enrolled in this study (mean age: 43.7 +/- 19.1 years old, 51.6% of women). For the ALM/ht2, reliability of the test-retest of the BIA was high with an ICC of 0.89 (95%CI: 0.86-0.92) when performed by the same operator and an ICC of 0.77 (95%CI: 0.72-0.82) when performed by two different operators. Agreement between ALM/ht2 assessed by DXA and BIA was low (ICC = 0.37 (95%CI: 0.25-0.48)). Mean ALM/ht2 was 9.19 +/- 1.39 kg/m2 with BIA and 7.34 +/- 1.34 kg/m2 with DXA, (p < 0001). A formula developed using a multiple regression analysis, and taking into account muscle mass assessed by BIA, as well as sex and body mass index, explains 89% of the ALM/ht2 assessed by DXA. CONCLUSIONS: Although our results show that the measure of ALM/ht2 by BIA is reliable, the agreement between DXA and BIA is low. Indeed, BIA seems to overestimate ALM/ht2 compared to DXA and, consequently, it is important to use an adapted formula to obtain measurement of the appendicular lean mass by BIA close to that measured by DXA.
Disciplines :
General & internal medicine
Author, co-author :
Buckinx, Fanny  ;  Université de Liège - ULiège > Département des sciences de la santé publique > Santé publique, Epidémiologie et Economie de la santé
Reginster, Jean-Yves  ;  Université de Liège - ULiège > Département des sciences de la santé publique > Santé publique, Epidémiologie et Economie de la santé
Dardenne, Nadia  ;  Université de Liège - ULiège > Département des sciences de la santé publique > Santé publique, Epidémiologie et Economie de la santé
Croisier, Jean-Louis ;  Université de Liège - ULiège > Département des sciences de la motricité > Kinésithérapie générale et réadaptation
Kaux, Jean-François  ;  Université de Liège - ULiège > Département des sciences de la motricité > Département des sciences de la motricité
Beaudart, Charlotte ;  Université de Liège - ULiège > Département des sciences de la santé publique > Santé publique, Epidémiologie et Economie de la santé
Slomian, Justine ;  Université de Liège - ULiège > Département des sciences de la santé publique > Epidémiologie clinique
Bruyère, Olivier  ;  Université de Liège - ULiège > Département des sciences de la santé publique > Santé publique, Epidémiologie et Economie de la santé
Language :
English
Title :
Concordance between muscle mass assessed by bioelectrical impedance analysis and by dual energy X-ray absorptionmetry among elderly people: a cross-sectional study
Publication date :
March 2015
Journal title :
BMC Musculoskeletal Disorders
eISSN :
1471-2474
Publisher :
BioMed Central
Volume :
16
Issue :
1
Pages :
60-67
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 24 March 2015

Statistics


Number of views
263 (43 by ULiège)
Number of downloads
10 (9 by ULiège)

Scopus citations®
 
138
Scopus citations®
without self-citations
126
OpenCitations
 
110

Bibliography


Similar publications



Contact ORBi