Unpublished conference/Abstract (Scientific congresses and symposiums)
EXAP 15254-5 Extrapolation of height above 4m in partition of metal sandwich panels
Dumont, Fabien; Wellens, Eric
2013EGOLF Meeting
 

Files


Full Text
Paper Helpdesk 2012-16 on EXAP 15254-5.pdf
Author postprint (241.47 kB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
EN 15254-5; extrapolation; height; metal sandwich panel; fire resistance
Abstract :
[en] When testing the fire resistance of metal sandwich panels, the annex B of EN 15254-5 gives rules for the consequently allowed extension of span length. The processing of these rules requires that specific measurements are carried out on joints between panels during the test. When a set of tests has been realised on panels of different thicknesses, but no measurement has been carried out on joints during these tests, the relevance of the following processing is analysed : 1. redo only the tests on panels of minimum and maximum thicknesses and carry out the measurement on joints ; 2. deduce the extended height allowed for these tests ; 3. interpolate these results to panels of intermediate thicknesses.
Disciplines :
Civil engineering
Author, co-author :
Dumont, Fabien ;  Université de Liège - ULiège > Département Argenco : Secteur SE > Ingénierie du feu
Wellens, Eric ;  Université de Liège - ULiège > Département Argenco : Secteur SE > Structures en béton
Language :
English
Title :
EXAP 15254-5 Extrapolation of height above 4m in partition of metal sandwich panels
Publication date :
March 2013
Number of pages :
12
Event name :
EGOLF Meeting
Event organizer :
EGOLF
Event place :
Champs-sur-Marne, France
Event date :
du 19 au 20 mars 2013
By request :
Yes
Audience :
International
Available on ORBi :
since 13 March 2013

Statistics


Number of views
191 (8 by ULiège)
Number of downloads
316 (3 by ULiège)

Bibliography