Article (Scientific journals)
Peritoneal equilibration test with conventional ‘low pH/high glucose degradation product’ or with biocompatible ‘normal pH/low glucose degradation product’ dialysates: does it matter?
VAN OVERMEIRE, Lionel; Goffin, Eric; Krzesinski, Jean-Marie et al.
2013In Nephrology Dialysis Transplantation, p. 1946-51
Peer Reviewed verified by ORBi
 

Files


Full Text
NDT 2012 L Van overmeire Peritoneal equilibration.pdf
Publisher postprint (155.51 kB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
albumin; beta-2 microglobulin; biocompatible solutions; peritoneal dialysis; peritoneal equilibration test
Abstract :
[en] Abstract Background. The evaluation of the peritoneal transport characteristics is mandatory in peritoneal dialysis (PD) patients. This is usually performed in routine clinical practice with a peritoneal equilibration test (PET) using conventional dialysates, with low pH and high glucose degradation product (GDP) concentrations. An increasing proportion of patients are now treated with biocompatible dialysates, i.e. with physiological pH and lower GDP concentrations. This questions the appropriateness to perform a PET with conventional solutions in those patients. The aim of our study is to compare the results of the PET using biocompatible and conventional dialysates, respectively. Methods. Nineteen stable PD patients (13 males, 6 females; mean age: 67.95 ± 2.36 years, mean body surface area: 1.83 ± 0.04 m2, dialysis vintage: 2.95 ± 0.19 years) were included, among which 10 were usually treated with biocompatible and 9 with conventional solutions. Two PETs were performed, within a 2-week interval, in each patient. PET sequence (conventional solution first or biocompatible solution first) was randomized in order to avoid ‘time bias’. Small (urea, creatinine and glucose), middle (beta-2-microglobulin) and large molecules’ (albumin and alpha-2-macroglobulin) dialysate/plasma (D/P) concentration ratios and clearances were measured during each PET. Ultrafiltration (UF) and sodium filtration were also recorded. Results of both tests were compared by the Wilcoxon paired test. Results. No statistical difference was found between both dialysates for small molecule transport rates or for sodium filtration and UF. However, a few patients were not similarly classified for small-solute transport characteristics within the PET categories. Beta-2-microglobulin and albumin D/P ratios at different time points of the PET were significantly higher with the biocompatible, when compared with the conventional, solutions: 0.10 ± 0.03 versus 0.08 ± 0.02 (P < 0.01) and 0.008 ± 0.003 versus 0.007 ± 0.003 (P = 0.01), respectively. A similar difference was also observed for beta-2-microglobulin that was higher with biocompatible dialysates (1.04 ± 0.32 versus 0.93 ± 0.32 mL/min, respectively). Conclusion. Peritoneal transport of water and small solutes is independent of the type of dialysate which is used. This is not the case for the transport of beta-2-microglobulin and albumin that is higher under biocompatible dialysates. Vascular tonus modification could potentially explain such differences. The PET should therefore always be carried out with the same dialysate to make longitudinal comparisons possible.
Disciplines :
Urology & nephrology
Author, co-author :
VAN OVERMEIRE, Lionel ;  Centre Hospitalier Universitaire de Liège - CHU > Néphrologie
Goffin, Eric;  Cliniques Universitaires Saint-Luc (Bruxelles) > Néphrologie
Krzesinski, Jean-Marie ;  Université de Liège - ULiège > Département des sciences cliniques > Néphrologie
Saint-Remy, Annie ;  Université de Liège - ULiège > Département des sciences cliniques > Néphrologie
Bovy, Philippe;  Centre Hospitalier Chrétien > Néphrologie
Cornet, Georges;  Centre Hospitalier Peltzer-La Tourelle > Néphrologie
BOVY, Christophe ;  Centre Hospitalier Universitaire de Liège - CHU > Néphrologie
Language :
English
Title :
Peritoneal equilibration test with conventional ‘low pH/high glucose degradation product’ or with biocompatible ‘normal pH/low glucose degradation product’ dialysates: does it matter?
Publication date :
2013
Journal title :
Nephrology Dialysis Transplantation
ISSN :
0931-0509
eISSN :
1460-2385
Publisher :
Oxford University Press, Oxford, United Kingdom
Pages :
1946-51
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 11 February 2013

Statistics


Number of views
122 (6 by ULiège)
Number of downloads
190 (3 by ULiège)

Scopus citations®
 
4
Scopus citations®
without self-citations
4
OpenCitations
 
3

Bibliography


Similar publications



Contact ORBi