Reference : A new statistical method for the automated detection of peaks in UV-DAD chromatograms...
Scientific journals : Article
Physical, chemical, mathematical & earth Sciences : Multidisciplinary, general & others
http://hdl.handle.net/2268/13236
A new statistical method for the automated detection of peaks in UV-DAD chromatograms of a sample mixture
English
Debrus, Benjamin mailto [Université de Liège - ULg > Département de pharmacie > Chimie analytique >]
Lebrun, Pierre mailto [Université de Liège - ULg > Département de pharmacie > Chimie analytique >]
Ceccato, Attilio mailto [Université de Liège - ULg > Département de pharmacie > Analyse des médicaments >]
Caliaro, Gabriel [Orailac Quality Solutions, Belgium]
Govaerts, Bernadette mailto [Institut de Statistiques, Université Catolique de Louvain, Belgique]
Olsen, Bernard A [Analytical Sciences R&D, Eli Lilly and Company, Lilly Technology Center, Indianapolis, IN 46285, United States]
Rozet, Eric mailto [Université de Liège - ULg > Département de pharmacie > Chimie analytique >]
Boulanger, Bruno [UCB Pharma SA, R&D Clinical Pharmacometrics, Brussels, Belgium]
Hubert, Philippe mailto [Université de Liège - ULg > Département de pharmacie > Chimie analytique >]
30-Jun-2009
Talanta
Elsevier Science
79
77-85
Yes (verified by ORBi)
International
0039-9140
Amsterdam
The Netherlands
[en] Independent components analysis ; High-order statistics ; Peak detection ; High-performance liquid chromatography ; UV-diode array detector
[en] One of the major issues within the context of the fully automated development of chromatographic methods consists of the automated detection and identification of peaks coming from complex samples such as multi-component pharmaceutical formulations or stability studies of these formulations. The same problem can also occur with plant materials or biological matrices. This step is thus critical and time-consuming, especially when a Design of Experiments (DOE) approach is used to generate chromatograms. The use of DOE will often maximize the changes of the analytical conditions in order to explore an experimental domain. Unfortunately, this generally provides very different and “unpredictable” chromatograms which can be difficult to interpret, thus complicating peak detection and peak tracking (i.e. matching peaks among all the chromatograms). In this context, Independent Components Analysis (ICA), a new statistically based signal processing methods was investigated to solve this problem. The ICA principle assumes that the observed signal is the resultant of several phenomena (known as sources) and that all these sources are statistically independent. Under those assumptions, ICA is able to recover the sources which will have a high probability of representing the constitutive components of a chromatogram. In the present study, ICA was successfully applied for the first time to HPLC–UVDAD chromatograms and it was shown that ICA allows differentiation of noise and artifact components from those of interest by applying clustering methods based on high-order statistics computed on these components. Furthermore, on the basis of the described numerical strategy, itwas also possible to reconstruct a cleaned chromatogram with minimum influence of noise and baseline artifacts. This can present a significant advance towards the objective of providing helpful tools for the automated development of liquid chromatography (LC) methods. It seems that analytical investigations could be shortened when using this type of methodologies.
Région wallonne : Direction générale des Technologies, de la Recherche et de l'Energie - DGTRE ; Eli Lilly and Company
Automated Development of Analytical Method, ADAM
Researchers ; Professionals
http://hdl.handle.net/2268/13236
10.1016/j.talanta.2009.03.009
http://www.elsevier.com/wps/find/journaldescription.cws_home/525438/description#description

File(s) associated to this reference

Fulltext file(s):

FileCommentaryVersionSizeAccess
Restricted access
Talanta 2009 - ICA peak detection.pdfPublisher postprint1.05 MBRequest copy

Bookmark and Share SFX Query

All documents in ORBi are protected by a user license.