Article (Scientific journals)
Evaluation of oxygen consumption during field exercise tests in Standardbred trotters
Van Erck, Emmanuelle; Votion, Dominique; Serteyn, Didier et al.
2007In Equine and Comparative Exercise Physiology, 4 (1), p. 43-49
Peer Reviewed verified by ORBi
 

Files


Full Text
VanErckE_EquineCompExerPhysiol_2007.pdf
Publisher postprint (1.83 MB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
Horse; Oxygen uptake; field; Treadmill
Abstract :
[en] Reasons for performing the study: In human exercise physiology, the current gold standard for evaluating aerobic capacity is the measurement of oxygen consumption (VO2max) and maximal oxygen uptake (VO2max). The evaluation of VO2, in horses is performed in some laboratories equipped with a treadmill but has only been exceptionally reported in field conditions because of the lack of adapted equipment. Objectives: The aim of this study was (1) to assess the feasibility of VO2 measurement on the track using a recently validated portable breath-by-breath gas analyser system adapted to horses (Cosmed K4b® and Equimask®), (2) to compare these results with those obtained during a treadmill exercise test and (3) to study correlations between VO2 and physiological parameters usually measured in field condition such as heart rate (HR), lactataemia (LA) and the speed at which HR equals 200 beats per minute (bpm) (V200) or LA 4 mmol-1 (VLA4). Methods: Five healthy Standardbred trotters in training were submitted to two stepwise incremental exercise tests, one driven on the racetrack and the other on a high-speed treadmill with a 4% incline. Speed (v), HR, ventilatory parameters and VO2 were continu¬ously recorded throughout the duration of the tests and LA was evaluated after each step. Results: All horses com¬pleted the test satisfactorily after an initial acclimatization to the mask. There were marked individual differences in ventilatory strategy, and breathing frequency (Rf) at the higher levels of exercise was noticeably low. The VCO2 measurements were incoherent. There were no significant differences between track and treadmill maximal data obtained during the last stop [VO2peak (track: 139.9 ± 8.9 ml kg-1min-1; treadmill: 139.9 ± 13.4 ml kg-1min-1), LAmax (track: 6.5 ± 1.6mmol-1; treadmill: 7.3 ± 3.Ommol-1-1), HRma (track: 229 ± 6.2 bpm; treadmill:222 ± 13 bpm)], although the maximal speed required to reach similar workloads was significantly higher on the track (11.9 ± 0.6 ms-1 vs. 9.7 ± 0.4 ms-1). The correlation between VO, and HR (r= 0.87; P < 0.001) and VO2 and LA (r = 0.75; P < 0,001) during both tests was good but no correlation was found between VO2peak and HRmax, LAmax, V200 or VLA4. Conclusions: This is the first report of a practical portable system to measure VO2 and ventilation continuously during high-speed field exercise tests. However, current mask design markedly influences ventilation and could have prohibited the attainment of VO2max Furthermore, consistent VCO2 measurements should be implemented by the manufacturers. Potential relevance: Continuous breath-by-breath ventilation and VO2 measurements can be recorded in horses in the field at submaximal levels. With necessary adaptations to the system entailed, this study opens new perspectives in the analysis of physiological and metabolic mechanisms of exercise in the equine species in genuine track conditions.
Disciplines :
Veterinary medicine & animal health
Author, co-author :
Van Erck, Emmanuelle ;  Université de Liège - ULiège
Votion, Dominique  ;  Université de Liège - ULiège > Département clinique des animaux de compagnie et des équidés > Anesthésiologie gén. et pathologie chirurg. des grds animaux
Serteyn, Didier  ;  Université de Liège - ULiège > Département clinique des animaux de compagnie et des équidés > Anesthésiologie gén. et pathologie chirurg. des grds animaux
Art, Tatiana ;  Université de Liège - ULiège > Département de sciences fonctionnelles > Phys. neuro-muscul., de l'effort - Méd. sport. des animaux
Language :
English
Title :
Evaluation of oxygen consumption during field exercise tests in Standardbred trotters
Publication date :
2007
Journal title :
Equine and Comparative Exercise Physiology
ISSN :
1478-0615
Publisher :
Cambridge University Press
Volume :
4
Issue :
1
Pages :
43-49
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 22 May 2009

Statistics


Number of views
185 (14 by ULiège)
Number of downloads
8 (5 by ULiège)

Bibliography


Similar publications



Contact ORBi