Article (Scientific journals)
Comparison of spin echo, gradient echo and fat saturation magnetic resonance imaging sequences for imaging the canine elbow
Snaps, Frédéric; Saunders, J.; Park, R. D. et al.
1998In Veterinary Radiology and Ultrasound, 39 (6), p. 518-523
Peer Reviewed verified by ORBi
 

Files


Full Text
SnapsF-VetRadUltrasound-1998.pdf
Publisher postprint (1.82 MB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
canine; elbow; anatomy
Abstract :
[en] Two comparison studies were performed. In the first conventional spin-echo (T1- and T2-weighted) sequences and a three-dimensional (3-D Fourier transform [3DFT]) echo gradient fast-imaging sequence were compared for imaging the canine normal elbow joint. In all three sequences, there was an isointense signal of the articular cartilage and a hyposignal of the subchondral bone, as compared with the muscles. The medial coronoid process of the ulna was clearly seen on the dorsal plane images, it appeared with a homogenous low-intensity signal. Its articulation with the radius was clearly outlined. In a second study, the 3DFT echo gradient fast-imaging sequence was compared to a fat saturation sequence on normal shoulder and elbow joints. Elbows were imaged with and without injection of saline, in an attempt to show the opposing cartilaginous articular surfaces. This distinction was possible in the shoulder joint but not in the elbow because of insufficient spatial resolution. On the three MRI sequences compared, gradient echo fast imaging with steady-state precession (GE FISP) sequence was found to be the most suitable for imaging the canine elbow joint.
Disciplines :
Veterinary medicine & animal health
Author, co-author :
Snaps, Frédéric ;  Université de Liège - ULiège > Département clinique des animaux de compagnie et des équidés > Imagerie médicale
Saunders, J.
Park, R. D.
Daenen, B.
Balligand, Marc ;  Université de Liège - ULiège > Département clinique des animaux de compagnie et des équidés > Chirurgie et clinique chirurgicale des petits animaux
Donderlinger, R. F.
Language :
English
Title :
Comparison of spin echo, gradient echo and fat saturation magnetic resonance imaging sequences for imaging the canine elbow
Publication date :
1998
Journal title :
Veterinary Radiology and Ultrasound
ISSN :
1058-8183
eISSN :
1740-8261
Publisher :
American College of Veterinary Radiology, Raleigh, United States - North Carolina
Volume :
39
Issue :
6
Pages :
518-523
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 05 May 2010

Statistics


Number of views
198 (4 by ULiège)
Number of downloads
1 (0 by ULiège)

Scopus citations®
 
41
Scopus citations®
without self-citations
40
OpenCitations
 
35

Bibliography


Similar publications



Contact ORBi