Article (Scientific journals)
Staging of regional nodes in AJCC stage I and II melanoma: 18FDG PET imaging versus sentinel node detection.
Belhocine, Tarik; Pierard, Gérald; De Labrassinne, Michel et al.
2002In Oncologist, 7 (4), p. 271-8
Peer Reviewed verified by ORBi
 

Files


Full Text
STAGING OF REGIONAL.pdf
Publisher postprint (415.02 kB)
Download

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
Adult; Aged; Disease Progression; Extremities/blood supply/pathology; False Positive Reactions; Female; Fluorodeoxyglucose F18/diagnostic use; Follow-Up Studies; Head and Neck Neoplasms/diagnosis/pathology; Humans; Injections, Intravenous; Lymph Nodes/pathology/radionuclide imaging/surgery; Male; Melanoma/diagnosis/pathology; Middle Aged; Neoplasm Staging; Predictive Value of Tests; Radiopharmaceuticals/diagnostic use; Recurrence; Sensitivity and Specificity; Sentinel Lymph Node Biopsy; Tomography, Emission-Computed
Abstract :
[en] PRIMARY PURPOSE: The staging of regional nodes by means of sentinel node detection has been shown to accurately detect subclinical nodal metastases from cutaneous melanoma. On the other hand, the oncological applications of 18F-fluoro-2-deoxy-D-glucose positron emission tomography (18FDG PET) are, nowadays, firmly established. However, the sensitivity of such metabolic imaging for staging the regional nodes in primary melanoma remains debatable. We prospectively assessed the actual value of PET for detecting sentinel node metastases in 21 consecutive patients presenting with early-stage melanoma. MATERIALS AND METHODS: Twenty-one melanoma patients scheduled for lymphatic mapping and sentinel lymphadenectomy underwent fully corrected whole-body PET using 18FDG. In all cases, the disease was initially classified as either stage I or II, from the latest version of the American Joint Committee on Cancer staging system. The sentinel node detection was systematically performed within the week following the PET scan. Serial sections of the sentinel nodes were analyzed by both conventional pathology and immunohistochemical staining. Metastatic sentinel nodes were also assessed for the size of tumor deposits and the degree of nodal involvement (focal, partial, or massive). The median follow-up time was 12 months. RESULTS: Six of the 21 patients (28.5%) had an involved sentinel node. PET was positive in only one case with a sentinel node >1 cm. In the five other cases, the sentinel nodes missed by PET were <1 cm with focal and/or partial involvements. One patient, free of regional nodal metastases in both sentinel node detection and PET imaging, had, however, a same-basin recurrence 3 months later. In another case, PET had one false positive result. Overall, the sentinel detection of subclinical nodal metastases had a sensitivity of 86%. PET detected only 14% of sentinel node metastases. CONCLUSIONS: Sentinel node detection remains the procedure of choice for detecting subclinical lymph node involvement from primary cutaneous melanoma. Owing to its limited spatial resolution, PET appears insufficiently sensitive to identify microscopic nodal metastases. As a practical consequence, metabolic imaging is not recommended as a first-line imaging strategy for staging regional lymph nodes in patients with stage I or II melanoma.
Disciplines :
Radiology, nuclear medicine & imaging
Author, co-author :
Belhocine, Tarik;  Centre Hospitalier Universitaire de Liège - CHU > Médecine nucléaire
Pierard, Gérald ;  Centre Hospitalier Universitaire de Liège - CHU > Dermatopathologie
De Labrassinne, Michel;  Centre Hospitalier Universitaire de Liège - CHU > Dermatologie
Lahaye, Thierry ;  Centre Hospitalier Universitaire de Liège - CHU > Chirurgie générale
Rigo, Pierre ;  Université de Liège - ULiège > Département des sciences de la motricité > Pathologie générale et médecine nucléaire
Language :
English
Title :
Staging of regional nodes in AJCC stage I and II melanoma: 18FDG PET imaging versus sentinel node detection.
Publication date :
2002
Journal title :
Oncologist
ISSN :
1083-7159
eISSN :
1549-490X
Publisher :
AlphaMed Company, Inc., Miamisburg, United States - Ohio
Volume :
7
Issue :
4
Pages :
271-8
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 27 April 2009

Statistics


Number of views
177 (1 by ULiège)
Number of downloads
288 (1 by ULiège)

Scopus citations®
 
89
Scopus citations®
without self-citations
86
OpenCitations
 
81

Bibliography


Similar publications