References of "Pediatric Critical Care Medicine"
     in
Bookmark and Share    
Full Text
Peer Reviewed
See detailAutomated respiratory cycles selection is highly specific and improves respiratory mechanics analysis.
RIGO, Vincent ULg; Graas, Estelle ULg; Rigo, Jacques ULg

in Pediatric Critical Care Medicine (2012), 13(4), 234-9

OBJECTIVE:: Selected optimal respiratory cycles should allow calculation of respiratory mechanic parameters focusing on patient-ventilator interaction. New computer software automatically selecting ... [more ▼]

OBJECTIVE:: Selected optimal respiratory cycles should allow calculation of respiratory mechanic parameters focusing on patient-ventilator interaction. New computer software automatically selecting optimal breaths and respiratory mechanic derived from those cycles are evaluated. DESIGN:: Retrospective study. SETTING:: University level III neonatal intensive care unit. SUBJECTS:: Ten mins synchronized intermittent mandatory ventilation and assist/control ventilation recordings from ten newborns. INTERVENTION:: The ventilator provided respiratory mechanic data (ventilator respiratory cycles) every 10 secs. Pressure, flow, and volume waves and pressure volume, pressure flow, and ventilator volume flow loops were reconstructed from continuous pressure/volume recordings. Visual assessment determined assisted leak-free optimal respiratory cycles (selected respiratory cycles). New software graded the quality of cycles (automated respiratory cycles). Respiratory mechanic values were derived from both sets of optimal cycles. We evaluated quality selection and compared mean values and their variability according to ventilatory mode and respiratory mechanic provenance. To assess discriminating power, all 45 "t" values obtained from interpatient comparisons were compared for each respiratory mechanic parameter. MEASUREMENTS AND MAIN RESULTS:: A total of 11,724 breaths are evaluated. automated respiratory cycle/selected respiratory cycle selections agreement is high: 88% of maximal kappa with linear weighting. Specificity and positive predictive values are 0.98 and 0.96, respectively. Averaged values are similar between automated respiratory cycle and ventilator respiratory cycle. C20/C alone is markedly decreased in automated respiratory cycle (1.27 +/- 0.37 vs. 1.81 +/- 0.67). Tidal volume apparent similarity disappears in assist/control: automated respiratory cycle tidal volume (4.8 +/- 1.0 mL/kg) is significantly lower than for ventilator respiratory cycle (5.6 +/- 1.8 mL/kg). Coefficients of variation decrease for all automated respiratory cycle parameters in all infants. "t" values from ventilator respiratory cycle data are two to three times higher than ventilator respiratory cycles. CONCLUSIONS:: Automated selection is highly specific. Automated respiratory cycle reflects most the interaction of both ventilator and patient. Improving discriminating power of ventilator monitoring will likely help in assessing disease status and following trends. Averaged parameters derived from automated respiratory cycles are more precise and could be displayed by ventilators to improve real-time fine tuning of ventilator settings. [less ▲]

Detailed reference viewed: 12 (2 ULg)
Full Text
Peer Reviewed
See detailCongenital cystic adenomatoid malformation type 0-a rare cause of neonatal death.
Stuhrmann, Stefan; Sachweh, Jorg; Bindl, Lutz et al

in Pediatric Critical Care Medicine (2007), 8(6), 580-581

OBJECTIVE: We give the first account of failure of extracorporeal membrane oxygenation therapy secondary to congenital cystic malformation of the lung (CCAM) type 0. DESIGN: Case report. SETTING ... [more ▼]

OBJECTIVE: We give the first account of failure of extracorporeal membrane oxygenation therapy secondary to congenital cystic malformation of the lung (CCAM) type 0. DESIGN: Case report. SETTING: Pediatric intensive care unit. PATIENT: A female neonate, appropriate for gestational age, with respiratory failure immediately after delivery. INTERVENTIONS: : Cardiopulmonary support with venoarterial extracorporeal membrane oxygenation. RESULTS: There was no improvement of pulmonary function, and the patient died. CCAM type 0 was diagnosed postmortem. CONCLUSIONS: CCAM type 0 should be considered as a rare differential diagnosis of irreversible lung pathologies leading to failure of extracorporeal membrane oxygenation therapy for neonatal respiratory failure. [less ▲]

Detailed reference viewed: 17 (0 ULg)