See detailPerformance Measurements of the microPET FOCUS 120 for Iodine-124 Imaging
Taleb, Dounia ULg; Bahri, Mohamed Ali ULg; Seret, Alain ULg et al

in IEEE Transactions on Nuclear Science (2012), PP

This study aimed to evaluate the performance of the microPET FOCUS 120 for 124I in terms of counting rate capability and image quality using the NEMA NU 4-2008 methodology. Scanner sensitivity was ... [more ▼]

This study aimed to evaluate the performance of the microPET FOCUS 120 for 124I in terms of counting rate capability and image quality using the NEMA NU 4-2008 methodology. Scanner sensitivity was measured for 124I for comparison and reached 75 cps/kBq, respectively, with the usual 350-650 keV energy window (EW) and 6 ns time window (TW). The noise equivalent count rate (NECR) index was defined as: NECR = RT2/(RP+RGP) (T = true, P = prompt, GP = γ-prompt). A rat phantom maximum NECR of 48 kcps was obtained for the 250-590 keV EW with 6 ns TW. An almost identical maximum NECR of 43 kcps was recorded for 350-590 and 350-650 keV EW and 6 ns TW. The 2 ns TW reduced the sensitivity and NECR by 40-50% for all EW. The mouse phantom NECR study was limited because of the maximum available activity concentration of 124I. The 250-590 keV EW showed the largest scatter and γ-prompt plus scatter fractions with 25.7% and 43%, respectively, for the rat phantom and 12.2% and 27% for the mouse phantom. With the 350-590 keV EW, these fractions decreased to 20% and 33.5% for the rat phantom and to 10% and 21% for the mouse phantom. The image quality was investigated with the NEMA NU 4-2008 dedicated phantom for four (two analytic and two iterative) 2D or 3D reconstruction methods. The lowest spillover ratios (SOR) for the phantom non-emitting regions were obtained for the 350-590 and 350-650 keV EWs. Recovery coefficients (RC) of the hot rods were the highest for the 350-590 keV EW except for the 1 mm rod. Scatter correction led to a large decrease in RC. The combination of the 350-590 keV EW with 6 ns TW appeared to be a good compromise between counting rate capability and image quality for the FOCUS 120, especially when maximum a posteriori reconstruction was used without scatter correction. Moreover this combination enabled the best quantification with an error as low as 0.36%. [less ▲]

Detailed reference viewed: 25 (7 ULg)
Full Text
Peer Reviewed
See detailGamma-ray attenuation for characterization of future space launcher fuels
Carapelle, Alain ULg; Collette, Jean-Pierre ULg

in IEEE Transactions on Nuclear Science (2006), 53(4, Part 1), 2023-2026

Gamma-ray attenuation is used to measure cryogenic mixture density. Parameters are optimized for specific space application. A simple error formula is established. The feasibility of the measurement is ... [more ▼]

Gamma-ray attenuation is used to measure cryogenic mixture density. Parameters are optimized for specific space application. A simple error formula is established. The feasibility of the measurement is demonstrated. The effect of container's walls is measured. An automatic measurement device is built. A theoretical calculation is made for the geometry of Ariane V launcher. [less ▲]