See detailHeart Graft Monitoring by the Ventricular Evoked Response
Mahaux, V.; Demoulin, J.C.; BIESSAUX, Yves ULg et al

in Pacing & Clinical Electrophysiology (2000), 23(11, Pt 2), 2003-5

Monitoring of the negative slew rate of the evoked T wave has been proposed as a noninvasive diagnostic tool to follow heart transplant recipients. The clinical contribution of this measurement on ... [more ▼]

Monitoring of the negative slew rate of the evoked T wave has been proposed as a noninvasive diagnostic tool to follow heart transplant recipients. The clinical contribution of this measurement on telemetrically recorded, paced unipolar ventricular electrograms was evaluated in the detection of grade 3 acute allograft rejection. Thirteen patients undergoing heart transplantation received a DDD pacemaker connected to two epimyocardial leads. Electrograms were recorded and digitized after each endomyocardial biopsy (EMB). The maximum slew rate of the descending slope of the repolarization phase (RSP) was extracted and normalized. A 20% downward shift of RSP from the reference value was considered abnormal. Results of signal processing were blinded during the first 6 months. Eleven patients completed the 6 months blinded period and two patients died. A total of 101 EMB were graded according to the International Society for Heart and Lung Transplantation classification. Grade 3 was assigned to 9 EMB. A significant difference was found between RSP values measured during grade 3 rejection episodes and other RSP values (P < 0.001). A diagnostic model consisting of a single threshold test confirmed the ability of RSP to predict significant signs of rejection on EMB (P < 0.0001). The sensitivity of RSP in detecting grade 3 rejections was 100%, specificity was 81%, negative predictive value 100%, and positive predictive value 35%. The use of RSP as a noninvasive monitoring tool to pose the indication for a biopsy would avoid 73% of EMB. Monitoring of transplanted hearts based on the analysis of the ventricular evoked response is promising and may markedly reduce the number of EMB. [less ▲]

Detailed reference viewed: 10 (0 ULg)
Peer Reviewed
See detailRhythmic and Electrophysiological Study after Dynamic Cardiomyoplasty
RADERMECKER, Marc ULg; Waleffe, André ULg; Gobin, Eric ULg et al

in Pacing & Clinical Electrophysiology (1995), 18(5, Pt 1), 965-72

To question the possible proarrhythmic effects of cardiomyoplasty (CMP), six adult goats were submitted to rhythmic and electrophysiological (EP) study 15 days before and 8 months after a posteroanterior ... [more ▼]

To question the possible proarrhythmic effects of cardiomyoplasty (CMP), six adult goats were submitted to rhythmic and electrophysiological (EP) study 15 days before and 8 months after a posteroanterior clockwise CMP procedure using Medtronic Cardiomyostimulator (CMS) (SP1005) and electrodes (SP5528) and completion of a progressive stimulation protocol. Pre and postoperative screening included a surface ECG, 24-hour Holter monitoring, high amplitude and filtered QRS averaging, and invasive EP study performed in the postoperative period with the CMS "ON" and "OFF." One-hour Holter recording with desynchronization of the CMS was obtained. Comparison of pre and postoperative ECG and rhythmic data showed no significant difference. High amplitude QRS averaging did not evidence meeting the usual criteria of late potentials. EP values were stable in both conditions and the aggressive EP program did not show evidence of increased susceptibility to arrhythmias. Asynchronous cardiomyostimulation did not induce arrhythmias. Our data strongly suggest that provided meticulous surgical technique is used, CMP does not significantly interfere with the electrical characteristics of the normal goat heart. The procedure, despite the disturbances it provokes, does not seem to be arrhythmogenic. The function of the CMS was always appropriate, even under stressful EP conditions. [less ▲]