References of "Lutteri, Laurence"
     in
Bookmark and Share    
Full Text
Peer Reviewed
See detailA propos de l'hémoglobine glycquée: les limites de son interprétation
Sepulchre, E; LUTTERI, Laurence ULg; CAVALIER, Etienne ULg et al

in Revue Médicale de Liège (2014), 69(9), 497-503

Determining the level of glycated haemoglobin, in particular its major fraction called HbA1c, is an attractive tool in the management of diabetic patients. In fact, it provides a global evaluation of the ... [more ▼]

Determining the level of glycated haemoglobin, in particular its major fraction called HbA1c, is an attractive tool in the management of diabetic patients. In fact, it provides a global evaluation of the glycemic control’s level through the past 8-12 weeks. However, this tool must be used with caution. First of all, it does not allow to examine the glycemic kinetics since it represents a glycemic average. Secondly, it does not allow to appreciate the glycemic evolution through the full day. This dosage needs then sometimes to be complemented by fingersticks blood glucose testing. Last but not least, caution is advised in interpreting the results because a number of physiological, pathological and technical factors might interfere with HbA1c measurement. It is therefore important that physicians keep a critical view of the values obtained. The paper reviews the different methods used to determine the level of glycated haemoglobin and their limitations. It also emphasizes the medical situations in which over- and under-estimation of the real HbA1c value could occur. It does not address the specific issue of the new expression values of HbA1c in mmol/mol instead of %. Moreover, the medical situations in which over- and under estimation of the real HbA1c value could occur will be described. [less ▲]

Detailed reference viewed: 5 (1 ULg)
Full Text
Peer Reviewed
See detailEl sindrome tirogastrico autoinmune : sus efectos sobre los micronutrientes y la tumorigenesis gastrica
VALDES SOCIN, Hernan Gonzalo ULg; LUTTERI, Laurence ULg; Cavalier, Etienne ULg et al

in Revista Argentina de Endocrinologia y Metabolismo (2014), 51

Detailed reference viewed: 28 (4 ULg)
Full Text
Peer Reviewed
See detailHeavy/light chain (HLC) and free light chain (FLC) analysis allow sensitive monitoring of multiple myeloma patients and AID detection of clonal changes
Dierge, Laurine; LUTTERI, Laurence ULg; Chauvet, D et al

in Biochimica Clinica (2013, May), 37(SS), 618

Detailed reference viewed: 43 (4 ULg)
Full Text
Peer Reviewed
See detailCreatinine - or cystatin C - based equations to estimate glomerular filtration in the general population: impact on the epidemiology of chronic kidney disease
DELANAYE, Pierre ULg; CAVALIER, Etienne ULg; Moranne, Olivier et al

in BMC Nephrology (2013), 14

Chronic kidney disease (CKD) is a major issue in public health. Its prevalence has been calculated using estimation of glomerular filtration rate (GFR) by the creatinine-based equations developed in the ... [more ▼]

Chronic kidney disease (CKD) is a major issue in public health. Its prevalence has been calculated using estimation of glomerular filtration rate (GFR) by the creatinine-based equations developed in the Modified Diet in Renal Disease (MDRD) and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) study. Recently, new equations based either on cystatin C (CKD-EPI Cys) or both cystatin and creatinine (CKD-EPI mix) have been proposed by the CKD-EPI consortium. The aim of this study was to measure the difference in the prevalence of stage 3 CKD, defined as an estimated GFR less than 60 mL/min/1.73 m2, in a population using these four equations. METHODS: CKD screening was performed in the Province of Liege, Belgium. On a voluntary basis, people aged over 50 years have been screened. GFR was estimated by the four equations. Stage 3 CKD was defined as a GFR less than 60 mL/min/1.73 m2. RESULTS: The population screened consisted of 4189 people (47% were men, mean age 63 +/- 7y). Their mean serum creatinine and plasma cystatin C levels were 0.88 +/- 0.21 mg/dL and 0.85 +/- 0.17 mg/L, respectively. The prevalence of CKD in this population using the MDRD, the CKD-EPI, the CKD-EPI Cys and the CKD-EPI mix equations was 13%, 9.8%, 4.7% and 5%, respectively. The prevalence of CKD was significantly higher with the creatinine-based (MDRD and the CKD-EPI) equations compared to the new cystatin C-based equations. CONCLUSIONS: Prevalence of CKD varies strongly depending on the method used to estimate GFR. Such discrepancies are of importance and must be confirmed and explained by additional studies, notably by studies using GFR measured with a reference method [less ▲]

Detailed reference viewed: 50 (19 ULg)
Full Text
Peer Reviewed
See detaille syndrome auto-immun thyrogastrique: ses effets sur les micronutriments et la tumorigénèse gastrique.
VALDES SOCIN, Hernan Gonzalo ULg; LUTTERI, Laurence ULg; CAVALIER, Etienne ULg et al

in Revue Médicale de Liège (2013)

Summary : The thyrogastric autoimmune syndrome (TAS) was described in patients in whom the serum cross-reacted both with gastric parietal cells antigens and thyroid antigens. We report two cases ... [more ▼]

Summary : The thyrogastric autoimmune syndrome (TAS) was described in patients in whom the serum cross-reacted both with gastric parietal cells antigens and thyroid antigens. We report two cases illustrating the spectrum of pathogical features of TAS. The first case associates Hashimoto’s thyroiditis and anemia perniciosa,and develops a gastric neuroendocrine tumor during follow up. The second case presents with a Graves’ disease and an autoimmune reversible gastritis, secondary to Helicobacter Pylori. Whereas type III autoimmune polyendocrinopathy is rare, TAS is frequent in our experience. Some 13% (32/240) of patients that we have prospectively followed affected with thyroiditis have also autoimmune gastritis. Helicobacter pylori is clearly implicated in 16% of autoimmune gastritis cases. Infection, malabsorption and gastritis are potentially reversible after bacterial eradication treatment. In the other 84% of gastritis patients, no histological or serological proof of Helicobacter pylori is found. Gastric autoimmunity is then irreversible, leading to gastric severe atrophy, hypochlorhydria and hypergastrinemia. Hypergastrinemia stimulates enterochromaffin cell hyperplasia, possibly progressing c to neuroendocrine tumors. We propose a diagnostic approach to improve the characterization of TAS. We review the literature on the subject and discuss some interesting animal models of infectious gastric autoimmunity [less ▲]

Detailed reference viewed: 40 (11 ULg)
Full Text
See detailThe thyrogastric syndrome : an under diagnosed etiology for acquired gastric neuroendocrine tumors. A case report
VALDES SOCIN, Hernan Gonzalo ULg; LOLY, Jean ULg; GAST, Pierrette ULg et al

in Abstract Book - 13th International Workshop on Multiple Endocrine Neoplasia (2012, September)

Detailed reference viewed: 45 (10 ULg)
Full Text
See detailAuto-immune gastritis characteristics in a large series of patients with auto-immune thyroiditis.
VALDES SOCIN, Hernan Gonzalo ULg; TOME, M.; LUTTERI, Laurence ULg et al

in XXIVth Belgian Week of Gastroenterology 2012 - Abstract book (2012)

Detailed reference viewed: 33 (5 ULg)
Full Text
Peer Reviewed
See detailComparison of the platelet concentrations obtained in platelet-rich plasma (PRP) between the GPS™ II and GPS™ III systems
Kaux, Jean-François ULg; Le Goff, Caroline ULg; Renouf, Julien et al

in Pathologie Biologie (2011), 59(5), 275-277

Introduction Platelet growth factors are known for their ability to speed up tissue healing (bone, skin, tendons, muscle). Various techniques make it possible to collect this platelet-rich plasma or PRP ... [more ▼]

Introduction Platelet growth factors are known for their ability to speed up tissue healing (bone, skin, tendons, muscle). Various techniques make it possible to collect this platelet-rich plasma or PRP. Methods This study compares the platelet concentrations obtained from five patients using GPS™ III, which has recently come onto the market, with those obtained using GPS™ II. Results and conclusion We obtain a platelet concentration that is six to nine times greater with GPS ™ II and GPS™ III, but there is no significant difference between the concentrations of PRP obtained with the two systems. [less ▲]

Detailed reference viewed: 82 (23 ULg)
Full Text
Peer Reviewed
See detailGPS™ II and GPS™ III: comparison of obtained platelets concentrations
Kaux, Jean-François ULg; Le Goff, Caroline ULg; Renouf, Julien et al

Poster (2010, March 20)

Introduction: Recently, several researches, essentially in vitro, demonstrated the positive effects of platelets on healing process of different tissues: bones, muscles and tendons. The aim of this study ... [more ▼]

Introduction: Recently, several researches, essentially in vitro, demonstrated the positive effects of platelets on healing process of different tissues: bones, muscles and tendons. The aim of this study is to compare the obtained platelets concentration between the new GPS™ III and GPS™ II. Methods: Two blood samples of 52 mL were taken in 5 volunteers and transferred respectively in both GPS™ II and GPS™ III. These devices were centrifuged at 3200 RPM during 15 min. The platelet-rich plasma (PRP) was thus collected and transferred in 6 mL test tubes. Cells count was done using an analyser ABX Micros 60. Results and conclusion: Platelets concentrations were more important from 6.2 up to 9.2 times with GPS™ II and from 7.3 up to 8.3 times with GPS™ III compared to blood samples. Efficiency of the collected platelets was around 92% for GPS™ II and 96% for GPS™ III. Both techniques made it possible to collect platelets but, unfortunately, also a lot of red and white blood cells. None of these parameters showed any significant difference (p>0.05). Conflicts of interests: The 10 devices GPS™ II and GPS™ III were provided gracefully by the firm Biomet Biologics TTC. [less ▲]

Detailed reference viewed: 97 (16 ULg)
Full Text
Peer Reviewed
See detailAnticorps anti-gliadines déamidées et maladie coeliaque : données actuelles et évaluation des faux positifs de cinq trousses de dosage
Lutteri, Laurence ULg; Sagot, Laurence; Chapelle, Jean-Paul ULg

in Annales de Biologie Clinique (2010), 68(2), 149-56

Recently, anti-deamidated gliadin antihodies were proposed for the serological diagnosis of celiac disease. We evaluate the specificity of different anti-deamidated gliadin antibodies ELISA in comparison ... [more ▼]

Recently, anti-deamidated gliadin antihodies were proposed for the serological diagnosis of celiac disease. We evaluate the specificity of different anti-deamidated gliadin antibodies ELISA in comparison with conventional anti-native gliadin kits. Serum sainples froin 46 non celiac patients trere analyzed by five different quantitative ELISA for anti-native gliadin, antideamidated gliadin and anti-fransglutaininase neo-epitope antibodies together with a screening ELISA. Twenty-four percent of the patients deinonstrated anti-native gliadin lgA and 63% 1gO antibodies. Using anti-dearnidated gliadin antibodies, tire number of false positive IgA and, particularly, 1gG results,markedly decreased in the non celiac patients: 21 and 24% respectively with anti-Gliadin (GAF-3X) Euroimmun kit, 7 and 26% with Bindazyme 1-lurnan Anti-Gliadin (MGP) The Binding Site kit and 0 and 41% with Celiac G+ Immco kit. The new assay which makes use of the physiological complex of tissue transglutaminase cross-linked with deamidated gliadin peptides, called neo-epitope, did not improve the differential diagnosis of celiac disease with 30% of false positive results in IgG (2% in IgA). IJsing the Inova screening kit, a positive resuit for IgA and/or IgG anti-deamidated gliadin and!or anti- tissue transglutaminase antibodies was obtained in 24% of the non celiac patients. In conclusion, our study assessed the superiority, in ternis of specificity, of anti-deamidated gliadin antibodies, over the conventional anti-gliadin antibodies for die differential diagnosis of celiac disease. [less ▲]

Detailed reference viewed: 444 (17 ULg)