References of "LUKAS, Pierre"
     in
Bookmark and Share    
Full Text
Peer Reviewed
See detailStandardization of DiaSorin and Roche automated third generation PTH assays with an international standard: impact on clinical populations
CAVALIER, Etienne ULg; DELANAYE, Pierre ULg; LUKAS, Pierre ULg et al

in Clinical Chemistry & Laboratory Medicine (2014), 52(8), 1137-41

Background: Standardization of parathyroid hormone (PTH) assays is a major issue, especially in hemodialyzed (HD) patients. Two automated third generation PTH assays (Roche Elecsys and DiaSorin Liaison ... [more ▼]

Background: Standardization of parathyroid hormone (PTH) assays is a major issue, especially in hemodialyzed (HD) patients. Two automated third generation PTH assays (Roche Elecsys and DiaSorin Liaison) are now available. These assays are specific for the (1-84) PTH and do not cross-react with the (7-84) fragment, contrary to second generation (intact) assays. We aimed to calibrate the two methods against the WHO International PTH Standard (IS) 95/646 to see if the two assays could provide comparable results in a population of healthy subjects, HD patients and patients suffering from primary hyperparathyroidism (PHP). Methods: We selected 79 healthy subjects and two populations of patients presenting PTH disorders: 56 HD and 27 PHP patients. We reconstituted the IS in a pool of human serum containing undetectable levels of 1-84 PTH and prepared 13 serum standards ranging from 0 to 2000 pg/mL. The standards were run on the two instruments to calibrate the assays on the IS. The different populations were run before and after restandardization. Results: As these kits were differently calibrated, the results obtained after restandarization were significantly different. Restandardization process improved concordance between assays and, taking the analytical variability of the two kits into account, the results could be considered to be similar. Conclusions: Restandardization of automated third generation PTH assays with the WHO 1-84 PTH Standard significantly reduces inter-method variability. Reference ranges and raw values are totally transposable from one method to the other in healthy subjects, but also in diseased patients, e.g., with HD or those suffering from PHP. [less ▲]

Detailed reference viewed: 23 (6 ULg)
Full Text
Peer Reviewed
See detailPerformance of the IDS-iSYS 1,25-dihydroxy vitamin D assay
GADISSEUR, Romy ULg; LUKAS, Pierre ULg; CARLISI, Ignazia ULg et al

Poster (2013, July)

Detailed reference viewed: 51 (21 ULg)
Full Text
Peer Reviewed
See detailEvaluation of the performance of the new automated IDS-ISYS 1,25-dihydroxy vitamin D assay
GADISSEUR, Romy ULg; LUKAS, Pierre ULg; CARLISI, Ignazia ULg et al

in Biochimica Clinica (2013, May), 37(SS), 498

Detailed reference viewed: 25 (7 ULg)
Full Text
Peer Reviewed
See detailEvaluation of the cross-reactivity of 25-hydroxyvitamin D2 on seven commercial immunoassays on native samples
LE GOFF, Caroline ULg; PEETERS, Stéphanie ULg; CRINE, Yannick ULg et al

in Clinical Chemistry & Laboratory Medicine (2012), 50(11), 2031-2

Detailed reference viewed: 38 (14 ULg)
Full Text
Peer Reviewed
See detailCross-reactivity of 25-hydroxyvitamin D2 in ADVIA Centaur Total Vitamin D
FORTUNATO, Antonio; LE GOFF, Caroline ULg; PEETERS, Stéphanie ULg et al

Poster (2012, May)

Detailed reference viewed: 27 (3 ULg)