See detailMicrocrystalline cellulose, a direct compression binder in a quality by design environment—A review
Thoorens, Grégory; Krier, Fabrice ULg; Leclercq, Bruno et al

in International Journal of Pharmaceutics (2014), 473(1-2), 64-72

Detailed reference viewed: 9 (1 ULg)
Full Text
Peer Reviewed
See detailTowards a real time release approach for manufacturing tablets using NIR spectroscopy
Pestieau, Aude ULg; Krier, Fabrice ULg; Thoorens, Grégory et al

in Journal of Pharmaceutical & Biomedical Analysis (2014), 98

Detailed reference viewed: 33 (9 ULg)
Full Text
Peer Reviewed
See detailDevice-based controlled local delivery of anastrozol into peritoneal cavity: in vitro and in vivo evaluation
Krier, Fabrice ULg; Riva, Raphaël ULg; Defrère, Sylvie et al

in Journal of Drug Delivery Science and Technology [=JDDST] (2014), 24(2), 198-204

Local treatment using drug loaded implants allows decreasing seric concentrations of the active ingredient with the purpose of limiting side effects and reaching perfect observance. Nowadays, some ... [more ▼]

Local treatment using drug loaded implants allows decreasing seric concentrations of the active ingredient with the purpose of limiting side effects and reaching perfect observance. Nowadays, some diseases are already treated with implants, but generally, by subcutaneous or intra vaginal implantation. In this work, a new implant device dedicated to the intra-peritoneal cavity was developed. For this purpose, a core-membrane polymer implant was selected. We propose an original method to determine the most appropriate membrane to control the release based on the use of Franz cells. The ability of the implant to release a constant quantity of an active ingredient will be assessed by testing implants in vitro. Finally, intra peritoneal cavity and subcutaneous in vivo implantation has been achieved in order to confirm the controlled and local release of the active ingredient. [less ▲]

Detailed reference viewed: 41 (8 ULg)
Full Text
Peer Reviewed
See detailPAT tools for the control of co-extrusion implants manufacturing process
Krier, Fabrice ULg; Mantanus, Jérome; Sacre, Pierre-Yves ULg et al

in International Journal of Pharmaceutics (2013), 458

Hot melt extrusion is a novel pharmaceutical manufacturing process technique. In this study, we identified four Critical Quality Attributes (CQAs) of the implant manufacturing process by hot melt ... [more ▼]

Hot melt extrusion is a novel pharmaceutical manufacturing process technique. In this study, we identified four Critical Quality Attributes (CQAs) of the implant manufacturing process by hot melt extrusion: the implant diameter, the quantity of the Active Pharmaceutical Ingredient (API), the homogeneity distribution of API and the thickness of the membrane. We controlled the implant diameter and the quantity of API in-line with a laser measurement, NIR and Raman spectroscopy, respectively. These two different spectroscopic techniques provided comparable results. In fact, the RMSEC and RMSECV were very close in each PAT technique but NIR spectroscopy was easier to use and less sensitive to external changes. For the control of the homogeneity of API distribution and the thickness of the membrane, we used successfully Raman spectroscopy imaging. These PAT tools help reducing analysis time. [less ▲]

Detailed reference viewed: 32 (14 ULg)
Full Text
See detailImplant comprising a core and a tube encasing the core
Donnez, Jacques; Van Langendonkt, Anne; Defrère, Sylvie et al

Patent (2012)

The present invention relates to an implant comprising: - a core material comprising polydimethylsiloxane or at least one hydrogel polymer; - a tube encasing said core material comprising an ethylene ... [more ▼]

The present invention relates to an implant comprising: - a core material comprising polydimethylsiloxane or at least one hydrogel polymer; - a tube encasing said core material comprising an ethylene vinyl acetate polymer or at least one hydrogel polymer; - a sealant for closure of the open ends of said tube comprising polydimethylsiloxane or a mono-, di-, or triacetoxy derivative thereof, or at least one hydrogel polymer; and - at least one active ingredient; wherein said at least one active ingredient is selected from the group comprising celecoxib, sulindac, tamoxifen, oestrogen, oestradiol, ethinyl oestradiol, mestranol, dienogest, norgestrel, levonorgestrel, desogestrel, norgestimate, ethynodiol diacetate, leuprorelin, buserelin, gonrelin, triptorelin, nafarelin, deslorelin, histrelin, and supprelin; and with the proviso that when the sealant is said at least one hydrogelpolymer, the core material comprises polydimethylsiloxane. Furthermore, the invention relates to an implant for use as a medicament. In particular, the invention relates to an implant for use in the treatment of endometriosis. [less ▲]

Detailed reference viewed: 42 (12 ULg)
Full Text
See detailImplant comprising a core and a tube encasing the core
Donnez, Jacques; Van Langendonkt, Anne; Defrère, Stéphanie et al

Patent (2012)

The present invention relates to an implant comprising: - a core material comprising polydimethylsiloxane or at least one hydrogel polymer; - a tube encasing said core material comprising an ethylene ... [more ▼]

The present invention relates to an implant comprising: - a core material comprising polydimethylsiloxane or at least one hydrogel polymer; - a tube encasing said core material comprising an ethylene vinyl acetate polymer or at least one hydrogel polymer; - a sealant for closure of the open ends of said tube comprising polydimethylsiloxane or a mono-, di-, or triacetoxy derivative thereof, or at least one hydrogel polymer; and - at least one active ingredient; with the proviso that when the sealant is said at least one hydrogel polymer, the core material comprises polydimethylsiloxane. Furthermore, the invention relates to an implant for use as a medicament. In particular, the invention relates to an implant for use in the treatment of endometriosis. [less ▲]

Detailed reference viewed: 26 (13 ULg)
Full Text
Peer Reviewed
See detailDesign space approach in the optimization of the spray-drying process
Lebrun, Pierre ULg; Krier, Fabrice ULg; Mantanus, Jérôme ULg et al

in European Journal of Pharmaceutics & Biopharmaceutics (2012), 80(1), 226-234

From a quality by design perspective, the aim of the present study was to demonstrate the applicability of a Bayesian statistical methodology to identify the design space (DS) of a spray-drying process ... [more ▼]

From a quality by design perspective, the aim of the present study was to demonstrate the applicability of a Bayesian statistical methodology to identify the design space (DS) of a spray-drying process. Following the ICH Q8 guideline, the DS is defined as the “multidimensional combination and interaction of input variables (e.g., materials attributes) and process parameters that have been demonstrated to provide assurance of quality”. Thus, a predictive risk-based approach was set up in order to account for the uncertainties and correlations found in the process and in the derived critical quality attributes such as the yield, the moisture content, the inhalable fraction of powder, the compressibility index and the Hausner ratio. This allowed quantifying the guarantees and the risks to observe whether the process shall run according to specifications. These specifications describe satisfactory quality outputs and were defined a priori given safety, efficiency and economical reasons. Within the identified DS, validation of the optimal condition was effectuated. The optimized process was shown to perform as expected, providing a product for which the quality is built in by the design and controlled set-up of the equipment, regarding identified critical process parameters: the inlet temperature, the feed rate and the spray flow rate. [less ▲]

Detailed reference viewed: 223 (40 ULg)
Full Text
Peer Reviewed
See detailIn vivo biocompatibility of three potential intraperitoneal implants
Defrère, Sylvie; Mestdagt, Mélanie ULg; Riva, Raphaël ULg et al

in Macromolecular Bioscience (2011), 11(10), 1335-45

The intraperitoneal biocompatibility of PDMS, polyHEMA and pEVA was investigated in rats, rabbits and rhesus monkeys. No inflammation was evidenced by hematological analyses and measurement of ... [more ▼]

The intraperitoneal biocompatibility of PDMS, polyHEMA and pEVA was investigated in rats, rabbits and rhesus monkeys. No inflammation was evidenced by hematological analyses and measurement of inflammatory markers throughout the experiment and by post-mortem examination of the pelvic cavity. After 3 or 6 months, histological analysis revealed fibrous tissue encapsulating PDMS and PEVA implants in all species and polyHEMA implants in rabbits and monkeys. Calcium deposits were observed inside polyHEMA implants. The intraperitoneal biocompatibility of all 3 polymers makes them suitable for the design of drug delivery systems, which may be of great interest for pathologies confined to the pelvic cavity. [less ▲]

Detailed reference viewed: 70 (34 ULg)
Full Text
Peer Reviewed
See detailOptimisation and validation of a fast HPLC method for the quantification of sulindac and its related impurities
Krier, Fabrice ULg; Brion, Michaël; Debrus, Benjamin ULg et al

in Journal of Pharmaceutical & Biomedical Analysis (2011), 54

The European Pharmacopoeia describes a liquid chromatography (LC) method for the quantification of sulindac, using a quaternary mobile phase including chloroform and with a rather long run time. In the ... [more ▼]

The European Pharmacopoeia describes a liquid chromatography (LC) method for the quantification of sulindac, using a quaternary mobile phase including chloroform and with a rather long run time. In the present study, a new method using a short sub-2μm column, which can be used on a classical HPLC system, was developed. The new LC conditions (without chloroform) were optimised by means of a new methodology based on design of experiments in order to obtain an optimal separation. Four factors were studied: the duration of the initial isocratic step, the percentage of organic modifier at the beginning of the gradient, the percentage of organic modifier at the end of the gradient and the gradient time. The optimal condition allows the separation of sulindac and of its 3 related impurities in six minutes instead of 18 min. Finally, the method was successfully validated using an accuracy profile approach in order to demonstrate its ability to accurately quantify these compounds. [less ▲]

Detailed reference viewed: 155 (51 ULg)
Full Text
Peer Reviewed
See detailOptimisation and validation of a fast HPLC method for the quantitation of sulindac and its impurities
Krier, Fabrice ULg; Brion, Michaël; Debrus, Benjamin ULg et al

Poster (2010, September)

Detailed reference viewed: 126 (43 ULg)
Full Text
See detailDéveloppement d'un implant intra-péritonéal contre l'endométriose
Krier, Fabrice ULg; Evrard, Brigitte ULg; Piel, Géraldine ULg et al

Scientific conference (2009, February 03)