References of "Vandepitte, Dirk"
     in
Bookmark and Share    
Full Text
See detailScientific and Technological Payloads Aboard the B3LSat CubeSat of the QB50 Network
Dell'Elce, Lamberto ULg; Kerschen, Gaëtan ULg; Delabie, Tjorven et al

in Proceedings of the 2nd IAA Conference on University Satellite Missions and Cubesat Workshop (2013)

Detailed reference viewed: 67 (8 ULg)
Peer Reviewed
See detailStatistical description of the internal geometry of a polymer textile composite using micro-computed tomography
Vanaerschot, Andy; Cox, Brian; Blacklock, Matthew et al

in Proceedings book European Conference on Composite Materials 2012 (2012)

Detailed reference viewed: 8 (1 ULg)
Full Text
See detailFilter failure analysis for the SWAP instrument on-board of PROBA2
Jonckheere, Stijn; Bergen, Bart; Halain, Jean-Philippe ULg et al

in COMPDYN (2011, May)

During its intensive testing campaign, SWAP (Sun Watcher using Active Pixel System detector and image Processing), an optical instrument developed by Centre Spatiale de Liege (CSL) and mounted onto the ... [more ▼]

During its intensive testing campaign, SWAP (Sun Watcher using Active Pixel System detector and image Processing), an optical instrument developed by Centre Spatiale de Liege (CSL) and mounted onto the Belgian satellite PROBA2, was subjected to a multitude of load cases to verify the integrity of the instrument during and after the launch and during the operational phase. The front and rear filters of SWAP, 200 nm thin films, survived intensive vibration tests on the qualification model and acceptance tests on the flight model, both at an instrument level. During the acoustic test on the spacecraft, the front filter exploded while the rear one was undamaged. A new, strengthened filter, coated with a very fine metal mesh was mounted in the instrument. However, this new filter has less good optical properties due to optical diffraction. Therefore a profound analysis of the filter failure is necessary to provide the best possible optical accuracy for future missions with similar equipment. Three load cases are further studied in this paper: the acceleration of the rocket, the instrument depressurisation and the vibro-acoustic behaviour under the large sound and vibration levels. The acceleration and depressurisation are studied together in a two-level computational fluid dynamics (CFD) analysis to assess the effect of the venting of the instrument on the differential pressure over the filter. The main focus of this paper is on a numerical vibro-acoustic analysis, following the procedures used by CSL and ESTEC (European Space Research and Technology Centre). This analysis needs special attention because of the presence of a stochastic excitation (diffuse field) and the very nonlinear behaviour of the filter itself due to its small thickness. Also, an additional postprocessing step based on filter displacements, rather than differential pressure, as done in the ESTEC procedure, is discussed. [less ▲]

Detailed reference viewed: 37 (3 ULg)
Full Text
Peer Reviewed
See detailA hybrid bioregulatory model of angiogenesis during bone fracture healing
Peiffer, Veronique; Gerisch, Alf; Vandepitte, Dirk et al

in Biomechanics & Modeling in Mechanobiology (2011), 10(3), 383-395

Bone fracture healing is a complex process in which angiogenesis or the development of a blood vessel net work plays a crucial role. In this paper, a mathematicalmodel is presented that simulates the ... [more ▼]

Bone fracture healing is a complex process in which angiogenesis or the development of a blood vessel net work plays a crucial role. In this paper, a mathematicalmodel is presented that simulates the biological aspects of fracture healing including the formation of individual blood vessels. The model consists of partial differential equations, several of which describe the evolution in density of the most important cell types, growth factors, tissues and nutrients. The other equations determine the growth of blood vessels as a result of themovement of leading endothelial (tip) cells. Branching and anastomoses are accounted for in the model. The model is applied to a normal fracture healing case and subjected to a sensitivity analysis. The spatiotemporal evolution of soft tissues and bone, as well as the development of a blood vessel network are corroborated by comparison with experimental data. Moreover, this study shows that the proposed mathematical framework can be a useful tool in the research of impaired healing and the design of treatment strategies. [less ▲]

Detailed reference viewed: 33 (9 ULg)