Strategy for DR-CALUX dioxin screening in feed under EC regulationScippo, Marie-Louise ; ; Focant, Jean-François et alin Organohalogen Compounds (2006), 68 Detailed reference viewed: 13 (1 ULg) Dioxin analysis in feed: cell-based assay versus mass spectrometry methodScippo, Marie-Louise ; ; Eppe, Gauthier et alin Accreditation and Quality Assurance (2006), 11(1-2), 38-43 In the determination of contaminants (dioxins, polychlorinated biphenyls, polyaromatic hydrocarbons), cell-based assays are useful methods for screening purposes: they are mainly characterized by high ... [more ▼] In the determination of contaminants (dioxins, polychlorinated biphenyls, polyaromatic hydrocarbons), cell-based assays are useful methods for screening purposes: they are mainly characterized by high sample throughput and lower costs than the Mass Spectrometry (MS)-based methods. Although cell-based assays can be sensitive enough for the determination of dioxins and related substances in agreement with the presently tolerable limits in food and feed (Regulation No. 2375/2001/EC and Directive 2003/57/EC respectively), their lack of specificity make their use rather questionable in control laboratories. In this paper, we present and compare results obtained from the analysis of a limited number of feed samples by both gas chromatography-high resolution mass spectrometry (GC-HRMS) and cell-based assay (DR-CALUX: dioxin responsive-chemically activated luciferase gene expression) methods. The DR-CALUX screening led to less than 10% false non-compliant and no false compliant results. In addition, there is a good correlation between GC-HRMS and DR-CALUX data. However, these preliminary results have to be confirmed on a larger number of samples to demonstrate that total toxic equivalent (TEQ), including dioxins, furans and dioxin-like polychlorobiphenyls (PCBs) can be monitored in feed and food with a cell-based assay. [less ▲] Detailed reference viewed: 99 (6 ULg) Evaluation of the DR-CALUX screening of food and feed, according to regulation levels including DL-PCBScippo, Marie-Louise ; ; Focant, Jean-François et alin Organohalogen compounds (2005), 67 Detailed reference viewed: 12 (2 ULg) Dioxin analysis in feed and food : cell-based assay versus mass spectrometry methodScippo, Marie-Louise ; ; Eppe, Gauthier et alPoster (2005) Detailed reference viewed: 7 (1 ULg) Evaluation of the DR-CALUX assay for screening of dioxins, furans and dioxin-like PCBs in food and feed: comparison of different approaches to correct raw data.Scippo, Marie-Louise ; ; Focant, Jean-François et alPoster (2005) Detailed reference viewed: 18 (2 ULg) |
||