Implication des propriétés biomécaniques des muscles transformés dans le mécanisme de la cardiomyoplastie; Sluse, Francis ; et alin Journal of Cardiology (1999), 9 Detailed reference viewed: 18 (5 ULg) Correction of Pressure Waveforms Recorded by Fluid-Filled Catheter Recording Systems: A New Method Using a Transfer EquationLambermont, Bernard ; Gérard, Paul ; Detry, Olivier et alin Acta Anaesthesiologica Scandinavica (1998), 42(6), 717-20 BACKGROUND: Pressure measuring systems using fluid-filled catheters can result in the recording of distorted pressure waveforms. It results in phase delay, overestimation of systolic and, to a lesser ... [more ▼] BACKGROUND: Pressure measuring systems using fluid-filled catheters can result in the recording of distorted pressure waveforms. It results in phase delay, overestimation of systolic and, to a lesser extent, of diastolic pressure. We designed and evaluated a method to correct this pressure waveform distortion using an appropriate transfer equation obtained from the dynamic response of the fluid-filled catheter. This transfer equation is based on the principle that a fluid-filled catheter recording system is considered as an underdamped dynamic system fully characterized by its natural frequency (omega n) and damping ratio (zeta). METHODS: Pressure waveforms, simultaneously recorded in vitro or in vivo by a fluid-filled catheter (Pc) and a micromanometer-tipped catheter (Pref), were used to validate the method. Dynamic response of the catheter used was obtained from a fastflush test. The corrected signal (Ppred) was obtained using omega n, zeta and the following transfer equation: d2Pc/dt2 + 2 omega n zeta dPc/dt + omega n 2Pc = C Ppred (t) After correction of Pc, Ppred was compared, using a linear regression, with Pref taken as reference. RESULTS: Our results showed that Ppred was fitted to Pref with excellent coefficient correlation (0.99). The mean error and the standard error of estimate were respectively -1.16 mmHg and 1.4 mmHg. CONCLUSION: This new method can convert the distorted pressure waveforms transmitted by any fluid-filled catheters into high-fidelity signals. It suppresses the phase delay and the over-estimation of systolic pressure induced by fluid-filled catheters. [less ▲] Detailed reference viewed: 19 (2 ULg) Comparison between Three- and Four-Element Windkessel Models to Characterize Vascular Properties of Pulmonary CirculationLambermont, Bernard ; Gérard, Paul ; Detry, Olivier et alin Archives of Physiology & Biochemistry (1997), 105(7), 625-32 In 11 anaesthetised pigs the accuracy of the three-element (WK3) and the four-element (WK4) Windkessel models to describe hemodynamic properties of the pulmonary circulation was compared during six ... [more ▼] In 11 anaesthetised pigs the accuracy of the three-element (WK3) and the four-element (WK4) Windkessel models to describe hemodynamic properties of the pulmonary circulation was compared during six different experimental conditions increasing pulmonary arterial pressure: increase in left atrial pressure, increase in alveolar pressure, increase in pulmonary blood flow, endotoxin shock, mechanical obstruction of left pulmonary artery or histamine infusion. Our results showed that WK4 fitted better the data than did WK3 because values of 1-R2 decreased from 6 percent (WK3) to 1.4 percent (WK4) when WK4 was used (P < 0.0005). 1-R2 was an adequate marker of the accuracy of the linear regression used to solve equations of both models. Compliance values estimated by WK4 were decreased by 5% comparatively to WK3 (P = 0.008). However, this difference can be considered as not physiologically relevant. Values of characteristic resistance corresponding to R1 + (L/R2C) in WK4 and to R1 in WK3 were not different (P = 0.22). The relative changes in R1, R2, and C observed due to the different experimental conditions were comparable regardless of the model. In conclusion, the conversion of WK3 in WK4 by adding an inductance, whose physiological meaning is not clear, resulted in an increased statistical accuracy of the model, but did not seem to have relevant influence on parameters or their evolution during experimental conditions. [less ▲] Detailed reference viewed: 84 (2 ULg) |
||