References of "Muzeau, J.-P"
     in
Bookmark and Share    
Full Text
See detailStructural member behaviour and analysis in case of fire
Lopes, N.; Vila Real, P.; Uppfeldt, B. et al

in Mazzolani, Federico (Ed.) Proceedings of Urban Habitat Constructions under Catastrophic Events (COST Action C26) (2008)

Detailed reference viewed: 59 (7 ULg)
Full Text
See detailSwaged bolts: modelling of the installation process and numerical analysis of the mechanical behaviour
Drean, M.; Habraken, Anne ULg; Bouchaïr, A. et al

in Computers & Structures (2002), 80

Swaged bolts are an alternative to high strength bolts in steel structures. To clarify the steps of the installation process, numerical modelling has been carried out. The relevant phenomena are described ... [more ▼]

Swaged bolts are an alternative to high strength bolts in steel structures. To clarify the steps of the installation process, numerical modelling has been carried out. The relevant phenomena are described and evaluated. This numerical calculation accounts for large displacements, large strains, mechanical plasticity and friction contact between the components of swaged bolts. The non-linear finite element code ‘‘Lagamine’’ designed for the simulation of metal forming processes has been used to provide the stress distributions in the components. [less ▲]

Detailed reference viewed: 20 (0 ULg)
See detailA proposal for beam-column interaction formulae
Boissonnade, N.; Jaspart, Jean-Pierre ULg; Muzeau, J.-P. et al

in Proceedings of the International Conference on "Coupled instabilities in metal structures CIMS'2000" (2000)

Detailed reference viewed: 26 (1 ULg)
See detailModélisation de la mise en oeuvre des boulons sertis précontraints
Drean, M.; Habraken, Anne ULg; Bouchair, A. et al

in Construction Métallique (1999), 4

Detailed reference viewed: 29 (3 ULg)