See detailOptimization of micro-HPLC peak focusing for the detection and quantification of low hepcidin concentrations.
Mansion, François ULg; Chiap, Patrice ULg; Houbart, Virginie ULg et al

in Journal of Separation Science (2011), 34(15), 1820-1827

Micro-high-performance liquid chromatography is a miniaturized, economic and ecological chromatographic system allowing the use of reduced size chromatographic columns. Coupled with electrospray ... [more ▼]

Micro-high-performance liquid chromatography is a miniaturized, economic and ecological chromatographic system allowing the use of reduced size chromatographic columns. Coupled with electrospray ionization tandem mass spectrometry, this technique can be used to detect and quantify low concentrations of peptides. In this study, hepcidin was used as the model compound and analysed using octadecylsilica stationary phase by means of a gradient elution mode at a flow rate of 4 muL/min. Several parameters were studied to optimize peak focusing. Using the methodology of experimental design, the mobile-phase gradient conditions and the sample composition were optimized in order to maximize the sensitivity and minimize retention time. Stability of the target peptide in solution was also demonstrated. [less ▲]

Detailed reference viewed: 45 (17 ULg)
Full Text
Peer Reviewed
See detailDevelopment and validation of a ultra-high-performance liquid chromatography-UV method for the detection and quantification of erectile dysfunction drugs and some of their analogues found in counterfeit medicines
Sacré, Pierre-Yves ULg; Deconinck, Eric; Chiap, Patrice ULg et al

in Journal of Chromatography. A (2011), 1218

Pharmaceutical counterfeiting is a permanently growing problem. Control laboratories are constantly analysing counterfeit medicines. In industrialised countries, one of the main counterfeited class of ... [more ▼]

Pharmaceutical counterfeiting is a permanently growing problem. Control laboratories are constantly analysing counterfeit medicines. In industrialised countries, one of the main counterfeited class of medicines are erectile dysfunction drugs. This paper describes the development and validation of a fast method to detect and quantify the three authorised phosphodiesterase type 5 inhibitors and five analogues. The method is based on the use of a sub-2 microns polar-embedded column with a gradient using acetonitrile as organic modifier and 10 mM ammonium formate buffer (pH 3.5) as aqueous component of the mobile phase. The separation was achieved in less than 4.5 min. The method has also been compared to the registered HPLC method for the assay of Viagra® which was considered as the reference method. The method is also compatible with on-line coupling mass spectrometry and will significantly reduce analysis times and solvent consumption. [less ▲]

Detailed reference viewed: 111 (13 ULg)
Full Text
Peer Reviewed
See detailPre-study and in-study validation of a SPE-LC-MS-MS method for the determination of 5-S-cysteinyldopa, a melanoma biomarker, in human plasma.
Martin, Gaelle; Mansion, François ULg; Houbart, Virginie ULg et al

in Talanta (2011), 84(2), 280-6

The incidence of malignant melanoma has increased over the past decades, particularly in Caucasian population. This disease presents defavourable prognosis in terms of survey, especially when detection ... [more ▼]

The incidence of malignant melanoma has increased over the past decades, particularly in Caucasian population. This disease presents defavourable prognosis in terms of survey, especially when detection occurs at the metastatic phase. Reliable analytical methods for biomarker determination are thus an interesting tool in pathology detection and follow-up. In this context, a method using SPE-LC-ESI-MS-MS for the determination of 5-S-cysteinyldopa (5-SCD) in human plasma was optimized. The presence of matrix effect was investigated in details while 5-SCD stability was studied according to FDA requirements for the validation of bioanalytical methods. Pre-study and in-study validations of the entire method were then successfully performed by applying the approach based on total measurement error and accuracy profiles over a concentration ranges from 1.6 to 200 ng/ml. Good results with respect to accuracy, trueness and precision were obtained. The maximum risk of observing future measurements falling outside the acceptance limits during routine analysis was also estimated. [less ▲]

Detailed reference viewed: 43 (8 ULg)
Full Text
Peer Reviewed
See detailCE-MS method development for peptides analysis, especially hepcidin, an iron metabolism marker.
Martin, Gaëlle ULg; Mansion, François ULg; Servais, Anne-Catherine ULg et al

in Electrophoresis (2009), 30(15), 2624-31

A method for the resolution of a peptides mixture including hepcidin-25, an iron metabolism marker, was developed by CE-ESI-MS. Several strategies were tested to optimize peptide separation, such as the ... [more ▼]

A method for the resolution of a peptides mixture including hepcidin-25, an iron metabolism marker, was developed by CE-ESI-MS. Several strategies were tested to optimize peptide separation, such as the addition of cyclodextrins or organic solvents in the BGE or the use of coated capillaries. Best results in terms of resolution, symmetry and efficiency were obtained with a BGE made of 500 mM ammonium acetate pH 4.5/ACN 70:30 v/v. Using the methodology of experimental design, BGE concentration, sheath liquid composition and MS-coupling parameters were then optimized in order to obtain the best signal intensity for hepcidin. Finally, a 225 mM BGE and a sheath liquid composed of isopropanol/water 80:20 v/v containing 0.5% v/v formic acid were selected as it constitutes the best compromise for selectivity, peak shape and sensitivity. [less ▲]

Detailed reference viewed: 105 (23 ULg)