See detailDecentralized mechanical ventilation with heat recovery
Aparecida Silva, Cleide; Gendebien, Samuel ULg; Hannay, Jules et al

in Proceedings of the 32nd AIVC Conference (2011, October)

A new local ventilation device is designed in such a way to procure ventilation “on demand” in each room, with a maximum of effectiveness and a minimum of energy waste. It consists in a parapipedic box to ... [more ▼]

A new local ventilation device is designed in such a way to procure ventilation “on demand” in each room, with a maximum of effectiveness and a minimum of energy waste. It consists in a parapipedic box to be located in one external wall (for example, just above a window) and containing two (injection and extraction) fans and a recovery heat exchanger. The design of the heat exchanger is associated to the selection of the two fans in view of the best compromise between heat recovery effectiveness and “auxiliary” consumptions. Great attention is paid to supply and exhaust air openings on both indoor and outdoor sides of the device, in order to get the highest ventilation effectiveness. A fair compromise is looked for between air flow control “authority” and “auxiliary” consumption. [less ▲]

Detailed reference viewed: 78 (3 ULg)
Full Text
Peer Reviewed
See detailPerformances of DAHT connected to building airthightness and indoor hygrothermal climate
Masy, Gabrielle; Lebrun, Jean; Gendebien, Samuel ULg et al

in Proceedings of the 32nd AIVC Conference (2011, October)

As building insulation level increases, the coupling of ventilation systems with building enveloppe airtightness becomes an important issue in order to improve buildings energy performances. A building ... [more ▼]

As building insulation level increases, the coupling of ventilation systems with building enveloppe airtightness becomes an important issue in order to improve buildings energy performances. A building ventilation model can be built on a set of resistances and generators in order to handle infiltration, natural ventilation as well as fan driven air flows. The model is able to assess the indoor air humidity level and the building energy balance. Double flow ventilation can be handled through decentralized air handling terminals (DAHT), integrated in window ledges. A model of DAHT can be combined with the model of a whole building envelope, including infiltrations as well as dynamic behaviour, allowing comparisons with classical ventilation systems, such as natural or hybrid systems, or with centralized double flow systems. Results regarding energy consumptions, air humidity levels and superficial condensation risks can be analysed. Fresh air flow can be calibrated in order to meet air quality standards related to indoor humidity level and CO2 concentration. The modelization of buiding indoor hygro-thermal climate allows a complete assessment of the seasonal heat exchanger efficiency, including heat recovery through the condensation of indoor air humidity when it flows through the exchanger. [less ▲]