References of "Lejeune, Jean-Luc"
     in
Bookmark and Share    
Full Text
Peer Reviewed
See detailL'image du mois : occlusion grêle sur hernie abdominale interne au travers de l'hiatus de Winslow
LEJEUNE, Jean-Luc ULg; BRASSEUR, Edmond ULg; lewin, M. et al

in Revue Médicale de Liège (2011), 66(9), 464-65

Detailed reference viewed: 17 (1 ULg)
Full Text
Peer Reviewed
See detailEvaluation of serum osteocalcin and CTX-I in Ardenner horses with special reference to juvenile interphalangeal joint disease.
Pastoret, V.; Carstanjen, B.; Lejeune, Jean-Luc ULg et al

in Journal of Veterinary Medicine. A, Physiology, Pathology, Clinical Medicine (2007), 54(9), 458-63

The first aim of this study was to establish a profile of age-related normal serum concentrations of osteocalcin (OC) in Ardenner horses. For this first part, blood samples from 49 healthy Ardenner horses ... [more ▼]

The first aim of this study was to establish a profile of age-related normal serum concentrations of osteocalcin (OC) in Ardenner horses. For this first part, blood samples from 49 healthy Ardenner horses were collected. The second aim was to study two biochemical markers of bone metabolism, OC and a carboxy-terminal cross-linking telopeptide of type I collagen (CTX-I), in 30 young Ardenner horses during 1 year. Amongst them, 17 showed lesions of juvenile degenerative joint disease in the distal forelimbs. A specific radioimmunoassay for equine OC was used to measure the serum concentration of the marker. The serum concentration of CTX-I was measured using a commercially available human assay validated for use in the horse. The effect of age, sex, season and health status (with or without lesions) was assessed. Levels of OC fall between birth and the adult stage: this decrease being most marked between birth and 1 year of age. This age-related decrease of OC was confirmed in the 30 young Ardenner horses, but CTX-I levels remained constant in this group. The Levels of the two markers changed significantly with the season with higher concentrations during the winter. No significant difference was shown either between the two sexes or between the two health statuses. [less ▲]

Detailed reference viewed: 25 (8 ULg)
Full Text
Peer Reviewed
See detailValidation of a portable equine metabolic measurement system
Art, Tatiana ULg; Duvivier, D. H.; van Erck, Emmanuelle et al

in Equine Veterinary Journal. Supplement (2006), 36

REASONS FOR PERFORMING STUDY: In equine sports medicine, VO2 has been measured exclusively with stationary systems, in laboratories equipped with a treadmill. Measurement during exercise in field ... [more ▼]

REASONS FOR PERFORMING STUDY: In equine sports medicine, VO2 has been measured exclusively with stationary systems, in laboratories equipped with a treadmill. Measurement during exercise in field conditions has not previously been reported because of the lack of portable equipment designed for horses. OBJECTIVES: A commercially available portable metabolic measurement system, based on breath-to-breath gas analysis and flow spirometry, was adapted to the horse's physiology and morphology (Cosmed K4b2 and Equimask) and its validity tested by (1) repeatability of the measures and (2) comparing metabolic data to those obtained by a reference method (RM). METHODS: To test the reproducibility of the measurements, 5 healthy saddle horses were subjected twice at 2 day intervals to a similar submaximal standardised incremental exercise test on a treadmill. The same horses performed twice at one week interval an incremental treadmill test to fatigue: the oxygen consumption and ventilation were measured once with the K4b2 system and once with the RM. The metabolic and ventilatory data obtained with both systems were compared. RESULTS: There was a good reproducibility of the metabolic measurements obtained by the K4b2 system at any workload. The VO2 obtained by both systems at any workload was not significantly different. However, the K4b2 expired fraction in CO2 (FETCO2) and carbon dioxide production (VCO2) were significantly lower at high and at maximal workloads. As a consequence, the values of the respiratory exchange ratio were too low and incompatible with normal physiological values. CONCLUSIONS: The good reproducibility of the metabolic and ventilatory measurements and the fact that the VO2 measurements at any workload were similar to the data obtained with the reference method suggested that this system may be used for comparison of repeated VO2 measurements in practical field conditions. POTENTIAL RELEVANCE: The K4b2 system could be used to improve knowledge of the energetic cost in different equine sports disciplines and offer the opportunity to undertake performance tests with genuine track conditions, on ridden or harnessed horses, rather than under laboratory conditions [less ▲]

Detailed reference viewed: 96 (10 ULg)
Full Text
Peer Reviewed
See detailMeningeal inflammatory pseudotumour: a case report.
Gollogly, L.; Sadzot, Bernard ULg; Lejeune, Jean-Luc ULg et al

in Acta Neurologica Belgica (2001), 101(2), 116-20

We report the case of a meningeal inflammatory pseudotumour occurring in a 23-year-old male presenting with focal seizures and headaches. Brain imaging techniques showed a 3.5 cm left parietal meningeal ... [more ▼]

We report the case of a meningeal inflammatory pseudotumour occurring in a 23-year-old male presenting with focal seizures and headaches. Brain imaging techniques showed a 3.5 cm left parietal meningeal tumour. Histology of the surgical specimen showed a dense lymphoid infiltrate permeating the dura mater and leptomeninges, consisting of a predominant polyclonal B cell population as confirmed by immunophenotyping and genotyping. Cultures of serum, CSF, and surgical specimen were negative and there was no serological evidence of a systemic dysimmune disease. The postoperative course was complicated by an episode of brain oedema resolving under steroid therapy. The patient, free from all medication, is asymptomatic at 3 years of follow-up. We discuss previously published cases and the nosology of intracranial inflammatory pseudotumours. [less ▲]

Detailed reference viewed: 22 (0 ULg)
Peer Reviewed
See detailAnalyse factorielle de la révision française de l'échelle A.M.D.P. : résultats d'une étude internationale de 388 cas
Bobon, D.; Mormont, Christian ULg; Doumont, A. et al

in Acta Psychiatrica Belgica (1982), 82

Detailed reference viewed: 65 (7 ULg)