References of "Hannigan, Jim"
     in
Bookmark and Share    
Full Text
See detailOzone tropospheric and stratospheric trends (1995-2012) at six ground-based FTIR stations (28°N to 79°N)
Vigouroux, Corinne; De Mazière, Martine; Demoulin, Philippe ULg et al

Poster (2013, April)

In the frame of the Network for the Detection of Atmospheric Composition Change (NDACC), contributing ground-based stations have joined their efforts to homogenize and optimize the retrievals of ozone ... [more ▼]

In the frame of the Network for the Detection of Atmospheric Composition Change (NDACC), contributing ground-based stations have joined their efforts to homogenize and optimize the retrievals of ozone profiles from FTIR (Fourier transform infrared) solar absorption spectra. Using the optimal estimation method, distinct vertical information can be obtained in four layers: ground-10 km, 10-18 km, 18-27 km, and 27-42 km, in addition to total column amounts. In a previous study, Vigouroux et al. (2008) applied a bootstrap resampling method to determine the trends of the ozone total and four partial columns, over the period 1995-2004 at Western European stations. The updated trends for the period 1995-2009 have been published in the WMO 2010 report. Here, we present the updated trends and their uncertainties, for the 1995-2012 period, for the different altitude ranges, above five European stations (28°N-79°N) and above the station Thule, Greenland (77°N). In this work, the trends have been estimated using a multiple regression model including some explanatory variables responsible for the ozone variability, such as the Quasi Biennial Oscillation (QBO), the solar flux, the Arctic Oscillation (AO) or El Niño-Southern Oscillation (ENSO). A major result is the significant positive trend of ozone in the upper stratosphere, observed at the Jungfraujoch (47°N), which is a typical mid-latitude site, as well as at the high latitude stations. This positive trend in the upper stratosphere at Jungfraujoch provides a sign of ozone recovery at mid-latitudes. [less ▲]

Detailed reference viewed: 10 (0 ULg)
Full Text
See detailOzone tropospheric and stratospheric trends (1995-2011) at six ground-based FTIR stations (28°N to 79°N)
Vigouroux, Corinne; De Mazière, Martine; Demoulin, Philippe ULg et al

Poster (2012, August)

Five ground-based stations in Western Europe, from 79°N to 28°N, all part of the Network for the Detection of Atmospheric Composition Change (NDACC), have joined their efforts to homogenize and optimize ... [more ▼]

Five ground-based stations in Western Europe, from 79°N to 28°N, all part of the Network for the Detection of Atmospheric Composition Change (NDACC), have joined their efforts to homogenize and optimize the retrievals of ozone profiles from FTIR (Fourier transform infrared) solar absorption spectra. Using the optimal estimation method, distinct vertical information can be obtained in four layers: ground—10 km, 10—18 km, 18—27 km, and 27—42 km, in addition to total column amounts. Vigouroux et al. (2008) applied a bootstrap resampling method to the ozone data to determine the trends of the total columns and of the partial columns in the above four layers, over the period 1995-2004. The updated trends for the period 1995-2009 have been published in the WMO 2010 report. Here, we present the updated trends, obtained using the bootstrap resampling method, for the 1995-mid-2011 period, for the five European stations and also for the station Thule, Greenland (77°N), which has joined this effort. The trends have also been estimated using a multiple regression model including the Quasi Biennial Oscillation (QBO) and the solar flux as explanatory variables. The trends obtained by the two methods will be compared and discussed. One of the major results is the significant positive trend observed in the upper stratosphere at the station Jungfraujoch (47°N), which provides a sign of ozone recovery at mid-latitudes. Significant positive trends are also observed in the upper stratosphere at the high latitude stations. [less ▲]

Detailed reference viewed: 7 (0 ULg)
Full Text
Peer Reviewed
See detailValidation of ACE-FTS v2.2 measurements of HCl, HF, CCl3F and CCl2F2 using space-, balloon- and ground-based instrument observations
Mahieu, Emmanuel ULg; Duchatelet, Pierre ULg; Demoulin, Philippe ULg et al

in Atmospheric Chemistry and Physics (2008), 8

Hydrogen chloride (HCl) and hydrogen fluoride (HF) are respectively the main chlorine and fluorine reservoirs in the Earth's stratosphere. Their buildup resulted from the intensive use of man-made ... [more ▼]

Hydrogen chloride (HCl) and hydrogen fluoride (HF) are respectively the main chlorine and fluorine reservoirs in the Earth's stratosphere. Their buildup resulted from the intensive use of man-made halogenated source gases, in particular CFC-11 (CCl3F) and CFC-12 (CCl2F2), during the second half of the 20th century. It is important to continue monitoring the evolution of these source gases and reservoirs, in support of the Montreal Protocol and also indirectly of the Kyoto Protocol. The Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS) is a space-based instrument that has been performing regular solar occultation measurements of over 30 atmospheric gases since early 2004. In this validation paper, the HCl, HF, CFC-11 and CFC-12 version 2.2 profile data products retrieved from ACE-FTS measurements are evaluated. Volume mixing ratio profiles have been compared to observations made from space by MLS and HALOE, and from stratospheric balloons by SPIRALE, FIRS-2 and Mark-IV. Partial columns derived from the ACE-FTS data were also compared to column measurements from ground-based Fourier transform instruments operated at 12 sites. ACE-FTS data recorded from March 2004 to August 2007 have been used for the comparisons. These data are representative of a variety of atmospheric and chemical situations, with sounded air masses extending from the winter vortex to summer sub-tropical conditions. Typically, the ACE-FTS products are available in the 10-50 km altitude range for HCl and HF, and in the 7-20 and 7-25 km ranges for CFC-11 and -12, respectively. For both reservoirs, comparison results indicate an agreement generally better than 5-10% above 20 km altitude, when accounting for the known offset affecting HALOE measurements of HCl and HF. Larger positive differences are however found for comparisons with single profiles from FIRS-2 and SPIRALE. For CFCs, the few coincident measurements available suggest that the differences probably remain within +/-20%. [less ▲]

Detailed reference viewed: 79 (31 ULg)
Full Text
Peer Reviewed
See detailValidation of ACE-FTS N2O measurements
Strong, Kimberley; Wolff, Mareile A; Kerzenmacher, Tobias E et al

in Atmospheric Chemistry and Physics (2008), 8(16), 4759-4786

The Atmospheric Chemistry Experiment (ACE), also known as SCISAT, was launched on 12 August 2003, carrying two instruments that measure vertical profiles of atmospheric constituents using the solar ... [more ▼]

The Atmospheric Chemistry Experiment (ACE), also known as SCISAT, was launched on 12 August 2003, carrying two instruments that measure vertical profiles of atmospheric constituents using the solar occultation technique. One of these instruments, the ACE Fourier Transform Spectrometer (ACE-FTS), is measuring volume mixing ratio (VMR) profiles of nitrous oxide (N2O) from the upper troposphere to the lower mesosphere at a vertical resolution of about 3-4 km. In this study, the quality of the ACE-FTS version 2.2 N2O data is assessed through comparisons with coincident measurements made by other satellite, balloon-borne, aircraft, and ground-based instruments. These consist of vertical profile comparisons with the SMR, MLS, and MIPAS satellite instruments, multiple aircraft flights of ASUR, and single balloon flights of SPIRALE and FIRS-2, and partial column comparisons with a network of ground-based Fourier Transform InfraRed spectrometers (FTIRs). Between 6 and 30 km, the mean absolute differences for the satellite comparisons lie between -42 ppbv and +17 ppbv, with most within +/- 20 ppbv. This corresponds to relative deviations from the mean that are within +/- 15%, except for comparisons with MIPAS near 30 km, for which they are as large as 22.5%. Between 18 and 30 km, the mean absolute differences for the satellite comparisons are generally within +/- 10 ppbv. From 30 to 60 km, the mean absolute differences are within +/- 4 ppbv, and are mostly between -2 and +1 ppbv. Given the small N2O VMR in this region, the relative deviations from the mean are therefore large at these altitudes, with most suggesting a negative bias in the ACE-FTS data between 30 and 50 km. In the comparisons with the FTIRs, the mean relative differences between the ACE-FTS and FTIR partial columns (which cover a mean altitude range of 14 to 27 km) are within +/- 5.6% for eleven of the twelve contributing stations. This mean relative difference is negative at ten stations, suggesting a small negative bias in the ACE-FTS partial columns over the altitude regions compared. Excellent correlation (R=0.964) is observed between the ACE-FTS and FTIR partial columns, with a slope of 1.01 and an intercept of -0.20 on the line fitted to the data. [less ▲]

Detailed reference viewed: 57 (26 ULg)
Full Text
Peer Reviewed
See detailValidation of HNO3, ClONO2, and N2O5 from the Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS)
Wolff, Mareile; Kerzenmacher, Tobias; Strong, Kimberley et al

in Atmospheric Chemistry and Physics (2008), 8(13), 3529-3562

The Atmospheric Chemistry Experiment (ACE) satellite was launched on 12 August 2003. Its two instruments measure vertical profiles of over 30 atmospheric trace gases by analyzing solar occultation spectra ... [more ▼]

The Atmospheric Chemistry Experiment (ACE) satellite was launched on 12 August 2003. Its two instruments measure vertical profiles of over 30 atmospheric trace gases by analyzing solar occultation spectra in the ultraviolet/visible and infrared wavelength regions. The reservoir gases HNO3, ClONO2, and N2O5 are three of the key species provided by the primary instrument, the ACE Fourier Transform Spectrometer (ACE-FTS). This paper describes the ACE-FTS version 2.2 data products, including the N2O5 update, for the three species and presents validation comparisons with available observations. We have compared volume mixing ratio (VMR) profiles of HNO3, ClONO2, and N2O5 with measurements by other satellite instruments (SMR, MLS, MIPAS), aircraft measurements (ASUR), and single balloon-flights (SPIRALE, FIRS-2). Partial columns of HNO3 and ClONO2 were also compared with measurements by ground-based Fourier Transform Infrared (FTIR) spectrometers. Overall the quality of the ACE-FTS v2.2 HNO3 VMR profiles is good from 18 to 35 km. For the statistical satellite comparisons, the mean absolute differences are generally within ±1 ppbv ±20%) from 18 to 35 km. For MIPAS and MLS comparisons only, mean relative differences lie within±10% between 10 and 36 km. ACE-FTS HNO3 partial columns (~15–30 km) show a slight negative bias of −1.3% relative to the ground-based FTIRs at latitudes ranging from 77.8° S–76.5° N. Good agreement between ACE-FTS ClONO2 and MIPAS, using the Institut für Meteorologie und Klimaforschung and Instituto de Astrofísica de Andalucía (IMK-IAA) data processor is seen. Mean absolute differences are typically within ±0.01 ppbv between 16 and 27 km and less than +0.09 ppbv between 27 and 34 km. The ClONO2 partial column comparisons show varying degrees of agreement, depending on the location and the quality of the FTIR measurements. Good agreement was found for the comparisons with the midlatitude Jungfraujoch partial columns for which the mean relative difference is 4.7%. ACE-FTS N2O5 has a low bias relative to MIPAS IMK-IAA, reaching −0.25 ppbv at the altitude of the N2O5 maximum (around 30 km). Mean absolute differences at lower altitudes (16–27 km) are typically −0.05 ppbv for MIPAS nighttime and ±0.02 ppbv for MIPAS daytime measurements. [less ▲]

Detailed reference viewed: 61 (16 ULg)
Full Text
Peer Reviewed
See detailCO measurements from the ACE-FTS satellite instrument: data analysis and validation using ground-based, airborne and spaceborne observations
Clerbaux, Catherine; George, Maya; Turquety, Solène et al

in Atmospheric Chemistry and Physics (2008), 8

The Atmospheric Chemistry Experiment (ACE) mission was launched in August 2003 to sound the atmosphere by solar occultation. Carbon monoxide (CO), a good tracer of pollution plumes and atmospheric ... [more ▼]

The Atmospheric Chemistry Experiment (ACE) mission was launched in August 2003 to sound the atmosphere by solar occultation. Carbon monoxide (CO), a good tracer of pollution plumes and atmospheric dynamics, is one of the key species provided by the primary instrument, the ACE-Fourier Transform Spectrometer (ACE-FTS). This instrument performs measurements in both the CO 1-0 and 2-0 ro-vibrational bands, from which vertically resolved CO concentration profiles are retrieved, from the mid-troposphere to the thermosphere. This paper presents an updated description of the ACE-FTS version 2.2 CO data product, along with a comprehensive validation of these profiles using available observations (February 2004 to December 2006). We have compared the CO partial columns with ground-based measurements using Fourier transform infrared spectroscopy and millimeter wave radiometry, and the volume mixing ratio profiles with airborne (both high-altitude balloon flight and airplane) observations. CO satellite observations provided by nadir-looking instruments (MOPITT and TES) as well as limb-viewing remote sensors (MIPAS, SMR and MLS) were also compared with the ACE-FTS CO products. We show that the ACE-FTS measurements provide CO profiles with small retrieval errors (better than 5% from the upper troposphere to 40 km, and better than 10% above). These observations agree well with the correlative measurements, considering the rather loose coincidence criteria in some cases. Based on the validation exercise we assess the following uncertainties to the ACE-FTS measurement data: better than 15% in the upper troposphere (8–12 km), than 30% in the lower stratosphere (12–30 km), and than 25% from 30 to 100 km. [less ▲]

Detailed reference viewed: 61 (14 ULg)
Full Text
Peer Reviewed
See detailValidation of ACE-FTS v2.2 methane profiles from the upper troposphere to the lower mesosphere
De Mazière, Martine; Vigouroux, Corinne; Bernath, Peter et al

in Atmospheric Chemistry and Physics (2008), 9(9), 2421-2435

The ACE-FTS (Atmospheric Chemistry Experiment – Fourier Transform Spectrometer) solar occultation instrument that was launched onboard the Canadian SCISAT-1 satellite in August 2003 is measuring vertical ... [more ▼]

The ACE-FTS (Atmospheric Chemistry Experiment – Fourier Transform Spectrometer) solar occultation instrument that was launched onboard the Canadian SCISAT-1 satellite in August 2003 is measuring vertical profiles from the upper troposphere to the lower mesosphere for a large number of atmospheric constituents. Methane is one of the key species. The version v2.2 data of the ACE-FTS CH4 data have been compared to correlative satellite, balloon-borne and ground-based Fourier transform infrared remote sensing data to assess their quality. The comparison results indicate that the accuracy of the data is within 10% in the upper troposphere – lower stratosphere, and within 25% in the middle and higher stratosphere up to the lower mesosphere (<60 km). The observed differences are generally consistent with reported systematic uncertainties. ACE-FTS is also shown to reproduce the variability of methane in the stratosphere and lower mesosphere. [less ▲]

Detailed reference viewed: 32 (8 ULg)