References of "Delva, Julien"
     in
Bookmark and Share    
Full Text
Peer Reviewed
See detailOdour annoyance assessments around landfill sites:methods and results
Nicolas, Jacques ULg; Romain, Anne-Claude ULg; Delva, Julien ULg et al

in Chemical Engineering Transactions (2008, June), 15

Detailed reference viewed: 54 (10 ULg)
Full Text
See detailLes odeurs dans l'environnement : dimensions sensorielles et méthodes d'évaluation.
Nicolas, Jacques ULg; Romain, Anne-Claude ULg; Delva, Julien ULg

in Journal des Ingénieurs (Le) (2008), 109

Les différentes composantes de la nuisance olfactive ainsi que les diverses méthodes d'évaluation correspondantes sont présentées de manière concrète et en relation avec les normes existantes. L'article ... [more ▼]

Les différentes composantes de la nuisance olfactive ainsi que les diverses méthodes d'évaluation correspondantes sont présentées de manière concrète et en relation avec les normes existantes. L'article détaille les mesures d'intensité et de concentration de l'odeur en laboratoire, les techniques d'échantillonnage sur sources canalisées ou surfaciques, la méthode d'olfactométrie déambulatoire pour les sources fugitives et diffuses. Il présente également la notion d'exposition, traduite par la courbe représentant un percentile spatio-temporel de concentration d'odeur. Il est également montré que les riverains peuvent être impliqués dans le cadre d'enquêtes ou dans des réseaux de vigies pour estimer la nuisance. <br />Enfin, les potentialités des réseaux de capteurs-gaz (nez électroniques), bientôt commercialisés par Odometric, spin-off de l'unité de recherche de l'ULg, sont également présentées. [less ▲]

Detailed reference viewed: 103 (10 ULg)
Full Text
Peer Reviewed
See detailComplementary approaches to measure environmental odours emitted by landfill areas
Romain, Anne-Claude ULg; Delva, Julien ULg; Nicolas, Jacques ULg

in Sensors and actuators. B, Chemical (2008), 131(1), 18-23

This paper presents different methods to assess the odour emission and the odour annoyance in the surroundings. It is shown, on the example of landfill areas and composting facilities, that chemical ... [more ▼]

This paper presents different methods to assess the odour emission and the odour annoyance in the surroundings. It is shown, on the example of landfill areas and composting facilities, that chemical analyses are helpful to identify key compounds of the odour release, and to set up the specification of a monitoring instrument. Sensitive methods, like dynamic olfactometry or sniffing team investigation, are mainly applicable to provide a global odour plume or an average annoyance zone. And the electronic nose can supply a warning signal to the plant manager or a real time estimation of the annoyance zone. [less ▲]

Detailed reference viewed: 38 (6 ULg)
Full Text
Peer Reviewed
See detailDevelopment and validating procedure of a formula to calculate a minimum separation distance from piggeries and poultry facilities to sensitive receptors
Nicolas, Jacques ULg; Delva, Julien ULg; Cobut, Pierre et al

in Atmospheric Environment (2008), 42(30), 7087-7095

A specific formula to calculate separation distance from piggeries and poultry facilities to sensitive receptor is developed for Walloon Region, in Belgium. The paper briefly presents the main principles ... [more ▼]

A specific formula to calculate separation distance from piggeries and poultry facilities to sensitive receptor is developed for Walloon Region, in Belgium. The paper briefly presents the main principles of the formula and discusses more deeply the compatibility of the distance approach with odour units, odour rate and percentiles usually applied to assess the odour annoyance zones. A method of validation is presented and tested to adjust the different parameters of the formula to Belgian field reality. A total of 43 farms of which 21 piggeries and 22 poultry facilities are visited and, for each case, the distance calculated by the formula is compared to the one deduced from odour annoyance criterion (10 ou m-3 at 98th percentile). Validation work results in discussing the sensibility of different factors of the formula and especially in adjusting a fitting factor to match the absolute distances to real field annoyance impression. Conclusions show that both approaches - separation distance formula and percentile evaluation - are coherent. The validation method allows parameter adjustment but should need further refinements to examine separately piggeries and poultry facilities. [less ▲]

Detailed reference viewed: 31 (1 ULg)
Full Text
Peer Reviewed
See detailMonitoring an odour in the environment with an electronic nose : requirements for the signal processing
Romain, Anne-Claude ULg; Delva, Julien ULg; Nicolas, Jacques ULg

Conference (2007, January)

Artificial olfaction system (the so-called electronic nose) is a very promising tool to monitor the malodour in the field. Usual measurement techniques of odour use human olfaction or conventional ... [more ▼]

Artificial olfaction system (the so-called electronic nose) is a very promising tool to monitor the malodour in the field. Usual measurement techniques of odour use human olfaction or conventional analytical techniques. The first category represents the real odour perception but is not applicable to measure continuously bad odours in the field. The second class of techniques gives the mixture composition but not the global information representative of the odour perception. The e-nose has the potentialities to combine "the odour perception" and the "monitoring in the field". However to be able to reach that goal, the signal processing has to be adapted to work in complex environment. The research group in Arlon has more than ten years experience in the measure of environmental malodours in the field. The paper presents the minimal requirements that the group considers as essential for artificial olfaction system to become successful for this application. [less ▲]

Detailed reference viewed: 47 (17 ULg)
Full Text
Peer Reviewed
See detailDifferent approaches to measure environmental odours emitted by landfill areas
Romain, Anne-Claude ULg; Delva, Julien ULg; Nicolas, Jacques ULg

Conference (2007)

This paper presents different methods to assess the odour emission and the odour annoyance in the surroundings. It is shown, on the example of landfill areas and composting facilities, that chemical ... [more ▼]

This paper presents different methods to assess the odour emission and the odour annoyance in the surroundings. It is shown, on the example of landfill areas and composting facilities, that chemical analyses are helpful to identify key compounds of the odour release, and to set up the specification of a monitoring instrument. Sensitive methods, like dynamic olfactometry or sniffing team investigation, are mainly applicable to provide a global odour plume or an average annoyance zone. And the electronic nose can supply a warning signal to the plant manager or a real time estimation of the annoyance zone. [less ▲]

Detailed reference viewed: 33 (13 ULg)
Full Text
Peer Reviewed
See detailApplying the electronic nose in the environment
Nicolas, Jacques ULg; Delva, Julien ULg; Romain, Anne-Claude ULg

Poster (2007)

The communication presents the various requirements imposed to electronic nose to become an instrument of environmental monitoring. Obstacles of the monitoring of real life environmental odours may be ... [more ▼]

The communication presents the various requirements imposed to electronic nose to become an instrument of environmental monitoring. Obstacles of the monitoring of real life environmental odours may be classified into three categories: • the final goal of the study, requiring to measure a global odour annoyance and not any gaseous emission, • the analysed sample itself, which is highly variable, due to the process evolution and to the influence of ambient parameters; • and the operating conditions, needing to work far from any building and sometimes at locations not easy to reach. The paper suggests some simple solutions to those problems. [less ▲]

Detailed reference viewed: 27 (9 ULg)
Full Text
See detailElectronic nose : a promising tool for landfill odour monitoring
Nicolas, Jacques ULg; Romain, Anne-Claude ULg; Delva, Julien ULg

in Lehmann, Ernest C. (Ed.) Landfill research focus (2007)

The paper briefly presents the advantages and drawbacks of the use of electronic noses to monitor continuously the odours generated by a landfill area. It stresses more particularly on the remaining ... [more ▼]

The paper briefly presents the advantages and drawbacks of the use of electronic noses to monitor continuously the odours generated by a landfill area. It stresses more particularly on the remaining obstacles to surmount before using the technique on a routine level. [less ▲]

Detailed reference viewed: 59 (9 ULg)