References of "Streel, Bruno"
     in
Bookmark and Share    
Full Text
Peer Reviewed
See detailThe transfer of a LC-UV method for the determination of fenofibrate and fenofibric acid in Lidoses: Use of total error as decision criterion
Rozet, Eric ULg; Mertens, Bénédicte; Dewé, Walthère ULg et al

in Journal of Pharmaceutical & Biomedical Analysis (2006), 42(1), 64-70

Two new statistical approaches to assess the validity of the transfer of a LC-UV method for the determination of fenofibrate and fenofibric acid were investigated and compared to the conventional ... [more ▼]

Two new statistical approaches to assess the validity of the transfer of a LC-UV method for the determination of fenofibrate and fenofibric acid were investigated and compared to the conventional approaches generally used in this domain. These new approaches, namely the Tolerance Interval and the Risk approaches, are based on the simultaneous evaluation of the systematic (or trueness) and random (or precision) errors of the transfer into a single criterion called total error (or accuracy). The results of the transfer showed that only the total error based approaches fulfilled the objective of an analytical method transfer, i.e. to give guarantees that each future measurement made by the receiving laboratory will be close enough to the true value of the analyte in the sample. Furthermore the Risk approach was the most powerful one and allowed the estimation of the risk to have future measurements out of specification in the receiving laboratory, therefore being a risk management tool. (c) 2006 Elsevier B.V. All rights reserved. [less ▲]

Detailed reference viewed: 124 (10 ULg)
Full Text
Peer Reviewed
See detailFully automated method for the liquid chromatographic-tandem mass spectrometric determination of cyproterone acetate in human plasma using restricted access material for on-line sample clean-up.
Christians, Benoit; Fillet, Marianne ULg; Chiap, Patrice ULg et al

in Journal of Chromatography. A (2004), 1056(1-2), 105-10

A new automated method for the quantitative analysis of cyproterone acetate (CPA) in human plasma has been developed using on-line solid phase extraction (SPE) prior to the LC-MS/MS determination. The ... [more ▼]

A new automated method for the quantitative analysis of cyproterone acetate (CPA) in human plasma has been developed using on-line solid phase extraction (SPE) prior to the LC-MS/MS determination. The method was based on the use of a pre-column packed with internal-surface reversed-phase material (LiChrospher RP-4 ADS, 25 mm x 2 mm) for sample clean-up coupled to LC separation on an octadecyl silica stationary phase by means of a column switching system. A 30 microl plasma sample volume was injected directly onto the pre-column using a mixture of water, acetonitrile and formic acid (90:10:0.1 (v/v/v)) adjusted to pH 4.0 with diluted ammonia as washing liquid. The analyte was then eluted in the back-flush mode with the LC mobile phase consisting of water, methanol and formic acid (10:90:0.1 (v/v/v)). The dispensing flow rates of the washing liquid and the LC mobile phase were 300 microl min(-1). Medroxyprogesterone acetate (MPA) was used as internal standard. The MS ionization of the analytes was achieved using electrospray (ESI) in the positive ion mode. The pseudomolecular ionic species of CPA and MPA (417.4 and 387.5) were selected to generate daughter ions at 357.4 and 327.5, respectively. Finally, the developed method was validated according to a new approach using accuracy profiles as a decision tool. Very good results with respect to accuracy, detectability, repeatability, intermediate precision and selectivity were obtained. The LOQ of cyproterone acetate was 300 pg ml(-1). [less ▲]

Detailed reference viewed: 37 (1 ULg)
Peer Reviewed
See detailHPLC enantiomeric separation of B-blocking drugs using an alpha 1-acid glycoprotein column
Ceccato, Attilio ULg; Hubert, Philippe ULg; Streel, Bruno et al

in Journal de Pharmacie de Belgique (1993), 48

Detailed reference viewed: 6 (1 ULg)