Mechanical effects of short-circuit currents in substations with strain bus systems. Parameter Analysis and simple method of calculation.Lilien, Jean-Louis ; in Proceedings of the CIGRE Symposium 06-85 (1985, June) SImple methods to evaluate short-circuit mechanical effects in substation. Detailed reference viewed: 19 (0 ULg) Mechanical effects of short-circuit currents in substations with strain bus systems. Medium complexity calculation methods.; Lilien, Jean-Louis ![]() in Proceedings of the CIGRE Symposium 06-85 (1985) This paper details various methods (medium complexity) for calculation of conductor tensions and displacements of substation under short-circuit loading. Detailed reference viewed: 26 (0 ULg) Utilisation rationnelle des méthodes de calcul automatique des champs quasi-statiques.; Lilien, Jean-Louis ; in Bossavit, Alain (Ed.) Actes du colloque MODELEC (1984, October 22) Dix années de développement et d'utilisation des méthodes :élément fini, différence finie, simulation de charges, intégrales de surface appliquées à l'électromagnétisme. Detailed reference viewed: 3 (0 ULg) Laboratory tests and normal operation regarding the electric field intensity.Lilien, Jean-Louis ; in Proceedinsg of the 4th ISH (1983, September 05) Influence of the electrode shape and room size in testing is investigated. Detailed reference viewed: 5 (0 ULg) Contraintes et conséquences électromécaniques liées au passage d'une intensité de courant dans les structures en câbles.Lilien, Jean-Louis ![]() Doctoral thesis (1983) Thèse consacrée au formalisme du problème (création d'un élément fini "cable"), à la mise au point d'une méthode de calcul par élément fini pour le résoudre (jeux de barres flexible), à la confrontation ... [more ▼] Thèse consacrée au formalisme du problème (création d'un élément fini "cable"), à la mise au point d'une méthode de calcul par élément fini pour le résoudre (jeux de barres flexible), à la confrontation avec des essais à Laborelec et à la mise au point de méthodes simplifiées. [less ▲] Detailed reference viewed: 15 (0 ULg) The behaviour of spacerless bundles due to high load current; ; Lilien, Jean-Louis ![]() in Electra (1983), 90 Overhead power lines with bundle conductors may be equipped without spacers. In such case overload may induce kissing phenomena or collapsing inside the bundle. This paper , following the first one ... [more ▼] Overhead power lines with bundle conductors may be equipped without spacers. In such case overload may induce kissing phenomena or collapsing inside the bundle. This paper , following the first one published also in ELECTRA this year, is describing the final formulation of the kissing current level, validated by scale model and full scale test on unspacered twin bundle line in vertical arrangement. [less ▲] Detailed reference viewed: 5 (1 ULg) The behaviour of spacerless bundles; Lilien, Jean-Louis ![]() in Electra (1983), 81 Overhead power lines in bundle conductors are sometimes installed without any spacers, mainly as a prevention against galloping phenomena. But such arrangement may cause some conductor collapse inside the ... [more ▼] Overhead power lines in bundle conductors are sometimes installed without any spacers, mainly as a prevention against galloping phenomena. But such arrangement may cause some conductor collapse inside the bundle during high load current (so called kissing phenomena). AFter such event, it is difficult to separate the subconductors and dramatic noise is created. The paper analyse the proble and model it to understand all parameters linked with it. [less ▲] Detailed reference viewed: 8 (0 ULg) The mechanical effects of short-circuit currents in substations with flexible conductors. Numerical Methods - Computer Approach.; Lilien, Jean-Louis ; in Proceedings of CIGRE 1982 (1982, September 01) A review of the application of advanced computer methods to the evaluation of the mecanical effects caused by the electromagnétic forces associated with short-circuit currents. Detailed reference viewed: 21 (0 ULg) Comportement électrodynamique des descentes sur poste en cas de défautLilien, Jean-Louis ; in Proceedings of the CIGRE Symposium 22-81 (1981) Etude par éléments finis d'une descente de ligne vers poste soumise aux effets mécaniques d'un courant de court-circuit. Detailed reference viewed: 9 (0 ULg) Sollicitations électrodynamiques dans les postes lors de défauts.Lilien, Jean-Louis ; ; in Proceedings of the IEEE Montech 1980 (1980, October 15) Comparaison entre calculs et essais sur un jeu de barres flexibles parcourus par une intensité de courant de court-circuit de 30 kA. Detailed reference viewed: 6 (0 ULg) Méthodes de calcul automatique de l'intensité du champ électrique; Lilien, Jean-Louis ; et alin Bulletin Scientifique de l'Association des Ingénieurs Electriciens sortis de l'Institut Electrotechnique Montefiore (1980), 1 On compare deux méthodes de calcul (élément fini et différence finie) du potentiel et du champ électrique dans des structures isolées au SF6. Detailed reference viewed: 8 (6 ULg) Transmission line conductor surface voltage gradients. Comparison between Mangoldt's and charge simulation methods.Lilien, Jean-Louis ; in Proceedings of the Third ISH (1979, August) Simulation of electric field around large bundle by charge simulation method. Detailed reference viewed: 17 (0 ULg) Efforts électrodynamiques dans les postes à haute tension lors de défauts polyphasés.Lilien, Jean-Louis ![]() in Hamza, M. H. (Ed.) Proceedings of the International Symposia on Energy and Technology. (1979, June) Modélisation et calcul par éléments finis d'un jeu de barres rigides et d'un jeu de barres flexibles d'un psote à haute tension parcouru d-ar des intensités de courant de court-circuit Detailed reference viewed: 37 (1 ULg) Efforts électrodynamiques dus aux courants de court-circuit dans les postes H.T.; Géradin, Michel ; Lilien, Jean-Louis ![]() in Revue de l'association des ingénieurs sortis de Montefiore (1978), 3 Calcul par éléments finis des efforts mécaniques liés aux courants de court-circuit dans les postes à haute tension. Detailed reference viewed: 18 (0 ULg) Application d'un principe variationnel incrémentiel au calcul par éléments finis de la répartition du champ magnétique dans les machines électriques.Cescotto, Serge ; Lilien, Jean-Louis ![]() in Revue de l'association des ingénieurs sortis de Montefiore (1977), 1 Formalisation du calcul par éléments finis du champ H et B dans une turbomachine, en tenant compte de la saturation. (calcul 2-D) Detailed reference viewed: 13 (1 ULg) |
||