References of "Lecomte, Frédéric"
     in
Bookmark and Share    
Full Text
Peer Reviewed
See detailTransfer of a conventional LC method for the screening of conterfeit antimalarial medicines to UHPLC
Nistor, Iolanda ULg; Lecomte, Frédéric ULg; Mbinze Kindenge, Jérémie et al

Poster (2010, September)

Detailed reference viewed: 121 (54 ULg)
Full Text
Peer Reviewed
See detailThe experimental design as practical approach to develop and optimize a formulation of peptide-loaded liposomes
Ducat, Emilie ULg; Brion, Michael; Lecomte, Frédéric ULg et al

in AAPS PharmSciTech (2010), 11(2), 966-975

To investigate the encapsulation of Print 3G, a peptidic agent that could reduce the angiogenic development of breast tumors, pegylated liposomes used as intravenous vectors were studied and characterized ... [more ▼]

To investigate the encapsulation of Print 3G, a peptidic agent that could reduce the angiogenic development of breast tumors, pegylated liposomes used as intravenous vectors were studied and characterized. Recently, the path of liposomes has been explored with success to improve the pharmacological properties of peptidic drugs and to stabilize them. In this study, loaded unilamellar vesicles composed of SPC:CHOL:mPEG2000-DSPE (47:47:6) were prepared by the hydration of lipid film technique. An HPLC method was developed and validated for the determination of Print 3G to calculate its encapsulation efficiency. Observed Print 3G adsorption on different materials employed during liposome preparation (such as glass beads, tubing, and connections for extrusion) led to the modification of the manufacturing method. The freeze-thawing technique was used to enhance the amount of Print 3G encapsulated into blank liposomes prepared using the hydration of lipid film procedure. Many factors may influence peptide entrapment, namely the number of freeze-thawing cycles, the lipid concentration, the peptide concentration, and the mixing time. Consequently, a design of experiments was performed to obtain the best encapsulation efficiency while minimizing the number of experiments. The lipid concentration and the number of freeze-thawing cycles were identified as the positive factors influencing the encapsulation. As a result of the optimization, an optimum was found and encapsulation efficiencies were improved from around 30% to 63%. Liposome integrity was evaluated by photon correlation spectroscopy and freeze-fracture electron microscopy to ensure that the selected formulation possesses the required properties to be a potential candidate for further in vitro and in vivo experiments. [less ▲]

Detailed reference viewed: 60 (31 ULg)
Full Text
Peer Reviewed
See detailNouveaux agents anti-inflammatoires en série N-(4-pyridyl)alcanesulfonamide
Renard, Jean-François ULg; Lecomte, Frédéric ULg; de Leval, Xavier et al

Conference (2010, May 21)

Detailed reference viewed: 70 (19 ULg)
Full Text
Peer Reviewed
See detailDevelopment and validation of a sensitive solid phase extraction/hydrophilic interaction liquid chromatography/mass spectrometry method for the accurate determination of glucosamine in dog plasma.
Hubert, Cédric ULg; Houari, Sabah ULg; Lecomte, Frédéric ULg et al

in Journal of Chromatography. A (2010), 1217

A sensitive and accurate LC/MS method was developed for the monitoring of glucosamine (GLcN) dog plasmatic concentration. In this scope, relatively low plasmatic concentrations of GLcN were expected ... [more ▼]

A sensitive and accurate LC/MS method was developed for the monitoring of glucosamine (GLcN) dog plasmatic concentration. In this scope, relatively low plasmatic concentrations of GLcN were expected, ranging from 50 to 1000ng/mL. Liquid chromatography coupled to simple quadrupole mass spectrometry detection (LC/MS) was selected bringing the selectivity and the sensitivity needed for this application. Additionally, a solid phase extraction (SPE) step was performed to reduce matrix and ion suppression effects. Due to the ionisable character of the compound of interest, a mixed-mode strong cation exchange (Plexa PCX) disposable extraction cartridge (DEC) was selected. The separation was carried out on a Zorbax SB-CN column (5mum, 4.6mm i.d.x250mm), considering hydrophilic interaction liquid chromatography (HILIC). Indeed, the mobile phase was made of methanol and 5mM ammonium hydrogen carbonate buffer at pH 7.5 (95/5, v/v). The detection was led at m/z ratios of 180.0 and 417.0, for GLcN and IS, respectively. Reliability of the results was demonstrated through the validation of the method using an approach based on the accuracy profile allowing managing the risk associated to the use of these methods in routine analysis: it is thus guaranteed that each future result will fall in the +/-30% acceptance limits with a probability of at least 90%. Successful application of the method to a preliminary pharmacokinetic study illustrated the usefulness of the method for pre-clinical studies. [less ▲]

Detailed reference viewed: 169 (62 ULg)
Full Text
Peer Reviewed
See detailSuggested mechanism of action of classical and deformable liposomes through pig ear skin
Gillet, Aline ULg; Lecomte, Frédéric ULg; Rozet, Eric ULg et al

in Journal of Pharmacy & Pharmacology (2010), 62(6), 788-807

Detailed reference viewed: 59 (14 ULg)