carence en vitamine D dans la population belge: Un vrai problème de santé publique?Cavalier, Etienne ; Bouüaert, Corine ![]() Conference given outside the academic context (2007) Detailed reference viewed: 165 (5 ULg) Evaluation of heterophile antibodies interference on Liaison PTH (Diasorin)Cavalier, Etienne ; Delanaye, Pierre ; Carlisi, Ignazia et alin Clinical Chemistry & Laboratory Medicine (2007, June), 45 Detailed reference viewed: 50 (5 ULg) PTH stability : preanalytical conditios influences for Liaison (Diasorin)Cavalier, Etienne ; Delanaye, Pierre ; Carlisi, Ignazia et alin Clinical Chemistry & Laboratory Medicine (2007, June), 45 Detailed reference viewed: 61 (4 ULg) PTH in hemodialyzed patientsCavalier, Etienne ![]() Conference (2007, May 24) Detailed reference viewed: 6 (0 ULg) Analytical variation in plasma renin activity: Implications for the screening of primary aldosteronismCavalier, Etienne ; Delanaye, Pierre ; Krzesinski, Jean-Marie et alin Clinical Chemistry (2007), 53(4), 803-804 Detailed reference viewed: 14 (3 ULg) Equations for GFR estimation: application and limitsCavalier, Etienne ; Delanaye, Pierre ![]() Conference (2007, March 24) Detailed reference viewed: 6 (1 ULg) MDRD equation for GFR estimation : analytical limitationsCavalier, Etienne ; Delanaye, Pierre ; Krzesinski, Jean-Marie et alConference (2007, March 23) Detailed reference viewed: 107 (1 ULg) Drawbacks and prognostic value of formulas estimating renal function in patients with chronic heart failure and systolic dysfunctionDelanaye, Pierre ; Krzesinski, Jean-Marie ; Cavalier, Etienne ![]() in Circulation (2007), 115(11), 333 Detailed reference viewed: 13 (3 ULg) Is cystatin C useful for the detection and the estimation of low glomerular filtration rate in heart transplant patients?Delanaye, Pierre ; Nellessen, Eric ; Cavalier, Etienne et alin Transplantation (2007), 83(5), 641-644 Although previously studied in patients with chronic kidney disease, there is less data for the use of cystatin C and cystatin C-based formulas in heart transplant recipients. The ability of creatinine ... [more ▼] Although previously studied in patients with chronic kidney disease, there is less data for the use of cystatin C and cystatin C-based formulas in heart transplant recipients. The ability of creatinine and cystatin C to detect renal failure (glomerular filtration rate [GFR] below 60 mL/min/1.73 m(2)) in heart transplant patients has been compared. The accuracy and precision of a creatinine-based formula (Modification of Diet in Renal Disease [MDRD]) versus a cystatin C-based formula (Rule's formula) to estimate GFR have also been studied. GFR was measured using the (51)Crethylenediamine tetraacetic acid tracer in 27 patients. There was no significant difference between GFR and the reciprocal of creatinine or cystatin C. Receiver operating characteristic curves for cystatin C and creatinine were similar. Both formulas were well correlated with the GFR. The bias of the cystatin C-based was significantly better than one of the MDRD formula, but the standard deviation appeared better for the MDRD formula (bias of +3.9 mL/min/1.73 m(2) versus +12 mL/min/1.73 m(2) and SD of 8.5 versus 11.6, respectively). Plasma cystatin C has no clear advantage over serum creatinine to detect renal failure in heart transplanted patients. [less ▲] Detailed reference viewed: 27 (3 ULg) Measurement uncertainty of creatinine in low values: Another good reason not to use the MDRD formula with low creatinine valuesCavalier, Etienne ; Delanaye, Pierre ; et alin Clinical Biochemistry (2007), 40(3-4), 285-286 Detailed reference viewed: 38 (2 ULg) Estimated glomerular filtration rateDelanaye, Pierre ; Cavalier, Etienne ; Krzesinski, Jean-Marie ![]() in Annals of Internal Medicine (2007), 146(1), 74-74 Detailed reference viewed: 14 (2 ULg) Variabilité du débit de filtration glomérulaire, de la créatinine et de la cystatine C plasmatiquesDelanaye, Pierre ; Cavalier, Etienne ; Depas, Gisèle et alin Néphrologie & Thérapeutique (2007), 3(5), 037 Detailed reference viewed: 24 (4 ULg) Acetylcysteine and enzymatic creatinine: take care for interference!Lognard, Michaël ; Cavalier, Etienne ; Chapelle, Jean-Paul et alin Acta Clinica Belgica (2007), 62(6), 462-462 Detailed reference viewed: 36 (11 ULg)![]() Stability of intact parathormone in hemodialyzed patients: a pragmatic study on Roche Elecsys assayCavalier, Etienne ; Delanaye, Pierre ; Carlisi, Ignazia et alPoster (2007) Detailed reference viewed: 50 (6 ULg) The RIFLE criteria: are the foundations robust?Delanaye, Pierre ; Krzesinski, Jean-Marie ; Cavalier, Etienne et alin Critical Care Medicine (2007), 35(11), 26692669-70 Detailed reference viewed: 25 (3 ULg) Impact of creatinine calibration in the MDRD equation on the epidemiology of renal failureDelanaye, Pierre ; Cavalier, Etienne ; Krzesinski, Jean-Marie ![]() Conference (2007) Detailed reference viewed: 22 (7 ULg) Analytical validation of the new version of the Liaison N-Tact PTH assayCavalier, Etienne ; Delanaye, Pierre ; et alin Clinical Chemistry & Laboratory Medicine (2007), 45(1), 105-107 We performed analytical validation of the new version of the Liaison N-Tact PTH (parathormone) assay according to NCCLS guidelines and compared this new generation of reagent with the Roche Elecsys PTH ... [more ▼] We performed analytical validation of the new version of the Liaison N-Tact PTH (parathormone) assay according to NCCLS guidelines and compared this new generation of reagent with the Roche Elecsys PTH assay. We showed that this new version is a sensitive and precise method with good recovery. Significant carryover was observed, but with limited clinical implications. We demonstrated that the new version of the Liaison PTH is in reasonably good agreement with the Roche Elecsys PTH assay, and as we observed no differences in a hemodialyzed population, moving from one method to the other should not affect the daily follow-up of patients. However, one should be cautious with the highest values (> 500 pg/mL). We established reference intervals of 12-54 pg/mL for the Liaison and 14-52 pg/mL for the Elecsys assay. [less ▲] Detailed reference viewed: 23 (4 ULg) Evaluation of the new BRAHMS-Biomerieux quantitative test for procalcitonin determinationGoffinet, Julie ; Bernard, Pierre ; Cavalier, Etienne et alin Acta Clinica Belgica (2007), 62(6), 463-463 Detailed reference viewed: 33 (6 ULg) High prevalence of vitamin D deficiency in pregnant women and new mothers in the area of Liège, BelgiumCavalier, Etienne ; Delanaye, Pierre ; Carlisi, Ignazia et alPoster (2007) Detailed reference viewed: 12 (3 ULg) Les interférences analytiques : les anticorps hétérophilesCavalier, Etienne ![]() Conference given outside the academic context (2006) Detailed reference viewed: 52 (2 ULg) |
||