References of "Turner, Wayman E"
     in
Bookmark and Share    
Full Text
Peer Reviewed
See detailMeasurement of selected polybrominated diphenyl ethers, polybrominated and polychlorinated biphenyls, and organochlorine pesticides in human serum and milk using comprehensive two-dimensional gas chromatography isotope dilution time-of-flight mass spectrometry
Focant, Jean-François ULg; Sjodin, Andreas; Turner, Wayman E. et al

in Analytical Chemistry (2004), 76(21), 6313-6320

A new method using comprehensive two-dimensional gas chromatography and isotope dilution time-of-flight mass spectrometry (GC x GC-IDTOFMS) for the simultaneous measurement of selected polychlorinated ... [more ▼]

A new method using comprehensive two-dimensional gas chromatography and isotope dilution time-of-flight mass spectrometry (GC x GC-IDTOFMS) for the simultaneous measurement of selected polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs), and brominated flame retardants is presented. In contrast to the reference methods based on classical GC/MS, a single injection of the extract containing all compounds of interest results in accurate identification and quantification. Using GC x GC ensures the chromatographic separation of most compounds, and TOFMS allows mass spectral deconvolution of coeluting compounds as well as the use of C-13-labeled internal standards for quantification. Isotope ratio measurements of the most intense ions for both native and labels ensure the required specificity. The use of this new method with an automated sample preparation procedure developed at the Centers for Disease Control and Prevention (CDC) for the analysis of human serum and milk compared favorably to conventional isotope-dilution one-dimensional gas chromatography-high-resolution mass spectrometty (GC-IDHRMS) for the different human serum and milk pools tested. The instrumental detection limits ranged between 0.5 pg/muL and 10 pg/muL and the method detection limits ranged between I and 15 pg/muL (N = 59 analytes). The reproducibility of the method was almost as good as with GC-IDHRMS, the relative standard deviations ranging between 1 and 11% for OCPs measured in human serum. OCP, PBDE, and PCB levels measured using the two methods were highly correlated, and the deviations between the two methods were below 20% for most analytes with concentrations above 1 ng/g milk lipids. [less ▲]

Detailed reference viewed: 177 (6 ULg)
Full Text
Peer Reviewed
See detailHigh-throughput analysis of human serum for selected polychlorinated biphenyls (PCBs) by gas chromatography-isotope dilution time-of-flight mass spectrometry (GC-IDTOFMS)
Focant, Jean-François ULg; Cochran, Jack W.; Dimandja, Jean-Marie D. et al

in Analyst (2004), 129(4), 331-336

A method for the high-throughput analysis of human serum for the 38 most prevalent polychlorinated biphenyls (PCBs) based on the use of fast gas chromatography-isotopic dilution time-of-flight mass ... [more ▼]

A method for the high-throughput analysis of human serum for the 38 most prevalent polychlorinated biphenyls (PCBs) based on the use of fast gas chromatography-isotopic dilution time-of-flight mass spectrometry (GC-IDTOFMS) is presented. The chromatographic separation time was 8 min. The separation of the congeners was carried out either chromatographically or analytically using the mass spectral deconvolution capability of the TOFMS. The instrument and the method limits of detection (LODs) were 0.5 pg muL(-1) and 20 pg muL(-1), respectively, which is not as good as the one achieved using high resolution mass spectrometry (HRMS) but allows the detection and quantification of the prevalent PCBs present in real human serum samples. The dynamic range covered 3 orders of magnitude. The comparison with the high resolution mass spectrometry (HRMS) reference method (28 min) was good and some separation improvements have been observed. This method allows the analysis of 100 samples per day per instrument. [less ▲]

Detailed reference viewed: 22 (3 ULg)
Full Text
Peer Reviewed
See detailRetrospective time trend study of brominated flame retardants and polychlorinated biphenyls in human serum from various regions of the United States, 1985-2002
Sjödin, Andreas; Jones, Richard S.; Lapeza, Chester et al

in Organohalogen Compounds (2003), 61

Detailed reference viewed: 16 (2 ULg)
Full Text
Peer Reviewed
See detailFast, sensitive, and comprehensive analytical methods including three-dimensional analysis (GCXGC-TOFMS) for measuring halogenated persistent organic pollutants
Patterson, Donald G.; Turner, Wayman E.; Sjödin, Andreas et al

in Organohalogen Compounds (2003), 60-65

Detailed reference viewed: 14 (2 ULg)